Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1238
    Keywords: Pulmonary function testing ; Lung compliance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To assess the reliability of estimates of static respiratory system compliance (Crs) made by junior hospital doctors caring for ventilated newborn infants. Design A prospective comparison of junior doctors' estimates of Crs to the Crs measured immediately afterwards Setting A regional neonatal intensive care nursery in Edinburgh, Scotland. Patients 46 ventilated newborn infants. Measurements and results Crs was estimated by three grades of junior doctor (Senior House Officer, Registrar and Research Fellow) using two different methods, (i) based on visual assessment of tidal volume in relation to inflation pressure (optical Crs) and (ii) directly using a visual analogue scale (analogue Crs). The Crs was then measured immediately afterwards using the single breath passive expiratory flow technique. The differences between the estimates and the measurements were calculated for each grade of observer and plotted against the corresponding measurements. The relationship between estimates and measurements was also expressed in terms of the coefficients of determinationr 2 calculated by least squares regression. With both methods of estimation observers tended to overestimate the Crs of infants with lower measured Crs and underestimate that of infants with higher measured Crs with many estimates differing from the measurements by more than 50%. Values ofr 2 ranged from 0.086 to 0.481 indicating a weak relationship between the estimates and the measurements Conclusions Junior doctors' estimates of Crs were unreliable and did not represent a useful method of assessing respiratory function. The clinical use of compliance measurements merits wider evaluation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 158 (1999), S. S13 
    ISSN: 1432-1076
    Keywords: Key words Neonatal intensive care ; Ethics ; Euthanasia ; Consent ; Decision making
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...