    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 20 (1997), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Prior to implantation of an atrial defibrillator, its effectiveness should be tested in each patient. A new catheter design for temporary use with electrodes for atrial defibrillation, electrogram sensing, and pacing was tested in this study. Atrial defibrillation thresholds defined using this temporary catheter were compared to the ones defined by catheters intended for chronic use with an implantable atrial defibrillator. Atrial defibrillation threshold was determined in six sheep using both types of catheters. Each animal was subjected to studies on 2 consecutive days. On the first day, shocks were applied between two of the temporary catheters. On the following day, permanent leads were inserted and atrial defibrillation threshold was redetermined. In both cases, defibrillation electrodes were positioned in the same heart location with one electrode in the distal coronary sinus and the second electrode in the right atrium. Atrial defibrillation threshold was obtained using 10 V increments or decrements to determine the lowest shock intensity needed to defibrillate the atria. Threshold was defined as the shock intensity at which 20 shock percent success was at or between 15 % and 85%. Statistical analysis showed no significant difference (P 〈 0.05) between atrial defibrillation threshold energy (0.53 J vs 0.55 J), voltage (122 V vs 120 V) or current (2.2 A vs 2.6 A) measured with the temporary catheters and the permanent leads, respectively. These data indicate that temporary catheters can be used for efficacy testing prior to implant of an atrial defibrillator, and that they predict atrial defibrillation threshold adequately for chronic leads.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We investigated in sheep, non-thoracotomy extraction of leads which had been chronically implanted in the right atrium (RA), coronary sinus/great cardiac vein (CS / GCV) and right ventricle (RV) for atrial implantable defibrillation. Clinical success of extraction as well as gross and histologic findings in the heart are reported. Six of nine sheep had successful extractions. The major complication was laceration of the wall of the great coronary vein with hemorrhage into the pericardial space and cardiac tamponade. Tissue damage included several reversible changes: intra-tissue hemorrhage, thrombosis in the veins, and some necrosis of fat, vascular wall and myocardium. Myocyte necrosis was estimated as 0.03 to 0.3 grams of tissue. Osseous and cartilaginous metaplasia was more common around the RA lead than the CS/GCV lead. In cases where the lead must be removed, removal from the venous insertion site using lead extraction equipment should only be attempted with surgical back-up for emergency thora-cotomy to control hemorrhage in the event of vessel laceration. Safer explantation of these leads from the vein entry site will require the development of new extraction procedures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-9686
    Keywords: Intracranial pressure ; Sound ; Vibration ; Sheep
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Although potentially fatal increases in intracranial pressure (ICP) can occur in a number of pathological conditions, there is no reliable and noninvasive procedure to detect ICP elevation and quantitatively monitor changes over time. In this experimental study, the relationships between ICP elevation and the vibrational response of the head were determined. An ovine animal model was employed in which incremental increases in ICP were elicited and directly measured through intraventricular cannulae. At each ICP increment, a vibration source elicited a flexural response of the animal's head that was measured at four locations on the skull using accelerometers. Spectral analysis of the responses showed changes in proportion to ICP change up to roughly 20 cm H2O (15 mm Hg) above normal; a clinically significant range. Both magnitude and phase changes at frequencies between 4 and 7 kHz correlated well (γ〉0.92) with ICP across the study group. These findings suggest that the vibrational response of the head can be used to monitor changes in ICP noninvasively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...