Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochemical and Biophysical Research Communications 202 (1994), S. 1586-1591 
    ISSN: 0006-291X
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This study was undertaken to investigate the outcome of epidural catheter insertion in the sitting or lateral position in mothers during labour. An initial prospective randomised study period (144 patients) suggested that the sitting position offered some superiority over the lateral in terms of technical ease of insertion. It was concluded, by minimising the subjective aspects in a follow-up, prospective nonrandomised study period (152 patients), that the determining factor lies in the skill and experience of the anaesthetist. There was no significant difference in complication rates or maternal discomfort between the two positions in either study period.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 35 (1980), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A technique is described of epidural anaesthesia for elective Caesarean section which has a 98% success rate, and an acceptably low incidence of intra-operative pain. The essentials of the technique are to produce and maintain complete sensory block front S5 to T6, employing a two-stage injection of bupivacaine 0–5% (mean dose 23 ml) and the use of gravity to ensure sacral block. Despite the use of pre-operative fluid loading and avoidance of caval occlusion, transitory hypotension occurred in 16% of patients. Vomiting, which occurred in 18% of patients, is a minor but distressing complication.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 49 (1994), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Spinal needles with a pencil-point tip and those of a finer gauge are known to be associated with a lower incidence of postdural puncture headache. This study set out to determine if fine pencil-point needles were acceptably easy to use in routine clinical practice. Two hundred and twelve women undergoing elective Caesarean section were randomly allocated to receive a subarachnoid block using either a 25 G or 27G Whitacre needle. Factors determining ease of needle use, adequacy of block, incidence of postdural puncture headache, backache and neurological sequelae were assessed. Successful intrathecal injection was achieved in all patients in the 25 G group. Using the 27 G needle, the anaesthetist failed to reach the subarachnoid space in eight patients of which seven subsequently had a successful intrathecal injection with a larger needle. These failures were attributed to excessive needle flexibility which was the only significant difference in ease of use between the 25G and 27G needles. In the 25G group, there was one severe postdural puncture headache which required an epidural blood patch and three mild headaches which resolved spontaneously. There were no postdural puncture headaches in the 27 G group. We conclude that the final choice of needle is a compromise between the ease of use and lower failure rate of the 25 G needle and the, as yet unproven, possibility of a lower incidence of postdural puncture headache with the 27 G needle.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 43 (1988), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This pressures used in vivo to administer epidural doses of local anaesthetic were recorded for 16- and 18-gauge multihole catheters. Observations were made on 10 patients in labour for each catheter gauge. The pressure range for the 16-gange catheters was 39.9–266 kPa, with a mean of 167.2 kPa, and for 18-gauge, a range of 53.2–266 kPa, mean. 159 kPa. Similar pressures were then applied in vitro to 10 catheters of each gauge, and the flow of fluid observed from the three holes. For each size of catheter, with increasing pressure, flow appeared at the proximal, then the middle, and finally the distal hole. This emphasises that the effect of epidural doses can vary depending on the pressure of injection, especially if the catheter had been passed partially through the dura.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 43 (1988), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A group of 685 obstetric patients were randomly allocated to have their epidural block performed using either a 16-gauge or an 18-gauge Tuohy needle. Bleeding was noted from needle or catheter trauma in 18% of patients and it proved impossible to insert the catheter in 3%. The majority of mothers experienced little discomfort during the procedure but 2% found insertion to be very uncomfortable. There was no significant difference in the complication rate, ease of use, or patient discomfort between the 18- or 16-gauge needles. Epidural analgesia, although safe, is not without hazard. It may be difficult to perform and may, rarely, cause considerable discomfort.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 42 (1987), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: One hundred patients undergoing emergency Caesarean section were treated with cimetidine 200 mg intramuscularly when the decision was made to deliver the patient by Caesarean section and, preceding general anaesthesia, 30 ml of 0.3 M sodium citrate was administered orally. No routine antacid therapy was employed during labour. No patient had a gastric aspirate pH of less than 2.7, and only one of less than 3. The regimen is simple and effective, and treats only those patients at risk of acid aspiration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 39 (1984), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 37 (1982), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 32 (1977), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...