Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A fast response calorimeter has been developed for the neutral-beam (NB) shine-through measurement. This calorimeter has the following advantages. (1) Temporal variation of the heat load onto the calorimeter can be measured. (2) Measurement under the relatively high heat flux environment is possible. (3) The calorimetric measurement under continuous and steady-state heat load environment is also possible. The verification of the measurement principle was done using an NB-injection system on the compact helical system (CHS) at the National Institute for Fusion Science (NIFS). The measured NB power densities are compared to the power densities being evaluated by the CHS-NB profile database. It was experimentally confirmed that the time constant of the measurement is about 7 ms. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2003-2011 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Accelerated electrons, which would lead to high thermal load of grids, have been suppressed in a high-current large hydrogen negative ion source. An extraction grid, with apertures shaped as the secondary electrons generated on the grid aperture surface would be shielded against the acceleration electric field, works well to prevent the secondary electrons from leaking to the acceleration gap, compared with a straight aperture extraction grid. Although the strong magnetic field at the extraction grid also lowers the electron leakage downstream, the aperture shaping of the extraction grid is more effective for the suppression of the accelerated electrons. The acceleration efficiency, defined by the ratio of the negative-ion current to the acceleration drain current, is improved to around 85%. There remains the accelerated electrons generated in the negative ion neutralization by collision with the residual neutral molecules during the acceleration. The direct interception of the accelerated negative ions with the downstream grid is small. The reduction of the operational gas pressure is quite important to achieve further improvement of the acceleration efficiency. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1114-1119 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Large high current hydrogen negative ion sources have been developed for the negative ion based neutral beam injector of the Large Helical Device (LHD) at NIFS. The prototype of the negative ion source is required to deliver a negative ion beam of 45 A at the beam energy of 125 keV. The optimization of 1/3 scale ion sources which are multicusp ion source with a rod and an external magnetic filter, respectively, has been investigated for the operation parameter of the plasma source. A total H− current of 16 A is extracted at an operating pressure of 0.9–0.45 Pa with Cs seeding operation. Negative hydrogen ion current is proportional to the input arc power and a beam current density of 45 mA/cm2 is attained. The beam extraction and acceleration characteristics are studied for a single-stage and a two-stage acceleration electrode. A beam divergence angle of 5 mrad is obtained. The results of research and development of a hydrogen negative ion source at NIFS will be reviewed. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2012-2019 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high-power large negative ion source has been operated for a long pulse duration. A three-grid single-stage accelerator is used, where the extraction grid is shaped so that the secondary electrons generated on the extraction grid would be prevented from leaking into the acceleration gap. A stable long-pulse arc discharge with an arc power of 100 kW has been obtained over 15 s by balancing an individual arc current flowing through each filament. The cesium-seeded operation is not influenced by a temperature rise over 100 °C of the plasma grid during the long-pulse arc discharge. As a result, 330 kW (91 keV–3.6 A) of the negative ion beam was produced stably for 10 s from an area of 25 cm×26 cm, where the current density was 21 mA/cm2 and the negative ion power density was 1.9 kW/cm2. The neutralization efficiency of accelerated negative ions has been measured including the residual positive and negative ion ratios by the water calorimetry of the beam dumps. The result agrees well with the calculation result. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1024-1026 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A large rf-driven hydrogen negative-ion source has been developed for a neutral beam injection (NBI) system in the fusion application. The rf plasma generator is a metal-walled multicusp bucket source, the dimensions of which are 30 cm×30 cm in cross section and 20 cm in depth. An induction coil antenna is fully immersed in the rf plasma generator, and is used for coupling the rf power into plasma. A strong external magnetic filter is generated in front of the plasma electrode for negative-ion production, and a filter field strength of more than 1000 G cm is required to reduce the electron temperature in the extraction region as low as 1 eV. Precisely 5.5 mA of a negative-ion current was obtained from a single aperture, corresponding to 4.1 mA/cm2 of current density. A small amount of cesium was supplied to the rf plasma generator from a cesium oven. As a result, a lowering of the operational gas pressure and improvement of the negative-ion production efficiency were observed. The optimum bias voltage was reduced by the cesium injection, which may be related to the reduction of the plasma potential. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 145 (1986), S. 63-65 
    ISSN: 1432-1076
    Keywords: Low birth weight infants ; Breast feeding ; Iron status ; Ferritin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Iron status in 15 low birth weight infants, 1000–2499 g, on breast feeding was studied longitudinally for the first 6 months of age, and the findings compared to those of 30 low birth weight infants receiving a proprietary iron-fortified formula. The two groups received no iron supplement until they developed iron deficiency. The incidence of iron deficiency at 6 months was significantly greater in the breast-fed group than in the formula-fed group (86% v 33%). The breast-fed group had significantly lower serum ferritin and hemoglobin values after 4 months of age. The findings indicate that breast-fed low birth weight infants have a higher risk of developing iron deficiency and should receive iron supplementation from 2 months of age.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...