Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 6 (1996), S. 67-67 
    ISSN: 1432-1068
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European spine journal 9 (2000), S. 75-79 
    ISSN: 1432-0932
    Keywords: Key words Aspergillosis ; Spondylodiscitis ; Debridement ; Spinal fusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Four cases of aspergillus spondylodiscitis were treated with operative debridement and fusion. In this rarely encountered mycotic infection of the spine in immunocompromised patients rapid destruction of the intervertebral disc and vertebral bodies can occur. In advanced cases antimycotic drug therapy is thought to be ineffective and a forcing indication for surgery exists when the destruction is progressive and spinal cord compression is imminent or manifest. Spinal instrumentation can be of help in maintaining or restoring spinal stability and maintaining spinal alignment. ¶In our four patients the aspergillus spondylodiscitis was successfully eradicated and fusion achieved. In two of three patients with a neurologic deficit, this deficit disappeared. Two patients died within 6 months after the operative treatment, due to complications related to the underlying illness. One patient was left with a subtotal paraplegia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 99 (1981), S. 137-141 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung 150 Gentamycin-PMMA-Kugeln wurden implantiert (+ 160 mg Gentamicin i.v. preop.) in eine 73jährige Frau, die an einer starken Einschränkung der Nierenfunktionen litt. Relativ häufig wurden die Plasma-Konzentrationen vom Gentamycin und die renalen Funktionen bestimmt. Die Konzentration von Gentamycin im Plasma erreichte einen Plateauwert von 3 μg/ml. Es trat keine Akkumulation von Gentamycin im Plasma auf.
    Notes: Summary 150 Gentamicin-PMMA-beads were implanted (+ 160 mg gentamicin i.v. preop.) in a woman aged 73 years and with severely impaired kidney function. Frequent determination of gentamicin plasma concentrations and renal functions were possible. The plasma concentration reached a plateau at approx. 3 μg/ml. No accumulation of gentamicin in plasma occurred.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...