Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 56 (1984), S. 1194-1196 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 9 (1982), S. 347-353 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A quantitative method is described for the determination of formaldehyde in biological tissues by stable isotope dilution using gas chromatography/mass spectrometry. (13C2H2)Formaldehyde is used as the isotopic diluet. After tissue homogenization, derivatization is carried out in situ with pentafluorophenylhydrazine, followed by extraction and analysis using selected ion monitoring. The sensitivity of the technique is higher than that of conventional methods of formaldehyde analysis, enabling endogenous formaldehyde to be quantitatively analyzed in tissues, even in samples as small as 20 mg wet weight. The effects of exposure to airborne formaldehyde or to airborne methyl chloride on the formaldehyde concentrations of several tissues of Fischer-344 rats are reported.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 6 (1979), S. 169-172 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A quantitative method is reported for the determination of n-hexane, 2-hexanone and 2,5-hexanedione in biological tissues by stable isotope dilution using gas chromatography mass spectrometry. n-[2H14]Hexane, 2-[2H5]hexanone and 2,5-[2H10]hexanedione are used as the isotopic diluents. After tissue homogenization and extraction of the three compounds in the presence of the deuterated internal standards, analysis is carried out in a single gas chromatographic injection by selected ion monitoring. Principal advantages of the technique are the ease of sample handling, rapidity of analysis and low limits of detection. The methodology is used to determine the organ distribution, pharmacokinetics and metabolism of n-hexane to 2-hexanone and 2,5-hexanedione in rats following inhalation exposure.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 22 (1987), S. 132-139 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The reaction of benzoyl ion with ammonia in multiple-collision conditions in the second quadrupole assembly of a triple quadrupole mass spectrometer at (laboratory) ion kinetic energies from 0 to 20 eV produced the even-electron ions [C6H5]+, [C6H5NH3·(NH3)m]+ (m = 0, 1) and [C6H5CONH3·(NH3)n]+ (n = 0, 1, 2, 3) and the odd-electron ions [C6H4NH3·(NH3)p]+· (p = 0, 1). Thermochemical information could not be obtained under multiple-collision conditions: both exothermic and endothermic reactions were observed, with no translational-energy onset measurable for the endothermic processes, nor decrease in the yield of the exothermic processes at high energies. The behaviour of cluster-ion intensities as pressure varied was qualitatively as expected. There are pressure and energy regions where spectra change little; if this feature were to be general, it would point to some utility for these conditions in qualitative analysis.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 413-415 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The ion-molecule reaction between six hexachlorobiphenyl positive molecular ions and ammonia in a triplequadrupole instrument to yield [M + NH3 - HCl]+. ions gives products whose abundances differ by at least an order of magnitude under uniform conditions. This reaction offers a way of distinguishing many isomers by a reaction that is different from the other demonstrated route, the loss of HCl from [M + O - Cl]- ions.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...