Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 348 (1994), S. 240-245 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The synthesis, characterization and application of a new kind of conjugate as tracer for use in time-resolved fluoroimmunoassay of triazine herbicides is described. Bovine serum albumin (BSA) served as carrier molecule, to which a triazine herbicide derivative and the Eu(III)-chelate W8044-Eu were subsequently coupled. The conjugate was characterized after each synthesis step by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The total composition was 1 BSA : 5.2 (±0.7) haptens : 5.1 (±0.4) fluorophores as calculated from the MALDI-MS data. The conjugate was successfully applied in competitive fluoroimmunoassays with sequential or simultaneous incubation of herbicide and tracer. With the sequential assay, the lowest detection limit was 0.1 μg/l for terbutryn. Results of assays performed with microtiter strips were compared with those obtained with commercial micro affinity columns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 661-664 
    ISSN: 0935-6304
    Keywords: SPME ; AED ; metazachlor ; pesticides ; waste water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 346 (1993), S. 757-760 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of Eu(III)-chelates as labels in fluoroimmunoassays for haptens is demonstrated. Previously mainly applied in clinical diagnostics, they have successfully been used for the determination of triazine herbicides in waters. The detection limit obtained was 0.05 μg/l for terbutryn and 0.1 μg/l for atrazine in the most sensitive assay formats of those tested. Monoclonal antibodes have been used in a competitive type immunoassay with a modified hapten coated onto microtiter strips, performing fluorescence detection with a conventional time-resolved fluorometer. Results of competitive assays and replacement assays have been compared. Due to the antibodies' high cross-reactivity the assay is useful for the determination of the whole triazine group while showing no interferences with other herbicides.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...