Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1432-1238
    Schlagwort(e): Key words PCO2 tonometry ; Measurement errors ; Intramucosal pH ; Blood gas analyzers ; Carbon dioxide
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: The choice of solution for gastrointestinal tonometry influences the PCO2 measurement bias, precision and the time required for equilibration. We compared saline with buffered solutions during in vitro tonometry, with respect to systematic and accidental measurement errors and equilibration time. Design: A prospective laboratory study. Measurements: Saline, phosphate, phosphate bicarbonate and succinylated gelatin solutions were equilibrated in a specialized blood gas tonometer at PCO2s of 2.7, 3.6, 4.5, 6.2 and 9.0 kPa, using calibration gases. Accidental errors were determined: the within-syringe decline of PCO2 and the effects of handling errors (five up and down movements of the plunger). The PCO2 build up in gastrointestinal tonometers was determined in 5000 ml saline baths with fixed PCO2 levels of 2.7 and 9.0 kPa. Results: The build up of PCO2 in phosphate bicarbonate and gelatin was about 4 and 2 times slower than in saline and phosphate, respectively, both for gas and gastrointestinal tonometers. The bias of the measured PCO2 at equilibrium was −15 % for saline, and between −1 and 3 % for phosphate, phosphate bicarbonate and gelatin. The precision was comparable among the solutions: 2 ± 1 % for saline, 2 ± 1 % for phosphate, 1 ± 0 % for phosphate bicarbonate and 1 ± 1 % for gelatin. The accidental errors were virtually absent with phosphate bicarbonate, intermediate with gelatin and largest with saline and phosphate. Conclusion: Phosphate bicarbonate buffer and succinylated gelatin allow accurate PCO2 measurements, but their equilibration is too slow for clinical application. The advantage of phosphate over saline solution is a smaller bias only. Thus, both saline and phosphate are currently the tonometer solutions of choice, provided that strictly anaerobic conditions are applied and the bias by the blood gas analyzer is known.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...