Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 74 (1999), S. 1278-1280 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We demonstrate the alteration of spontaneous emissions in semiconductor microcavity triodes, in which the carriers are injected by current into a single quantum well (QW) active region and the emission wavelength was varied by the voltage applied to the QW through the quantum confined Stark effect. The clear changes in the emission spectra and radiation patterns with the change of the voltage manifest that the spontaneous emission is well modified by the microcavity under the control of the applied voltage. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The current study was designed to determine the anaesthetic induction time required for tracheal intubation (TimeEI) with equipotent inspired concentrations of 5% sevoflurane and 2.5% halothane in oxygen. TimeEI that prevents 50% and 95% of patients from coughing and gross purposeful muscular movements after intubation was defined as TimeEI50 and TimeEI95, respectively. Thirty-six patients aged 1–7 years were enrolled in the study. Anaesthesia was induced via mask and when TimeEI attained a predetermined value, intubation was performed using an uncuffed tube. Each TimeEI at which tracheal intubation was attempted was predetermined according to the up-and-down method. When intubation was accomplished without gross purposeful muscular movements, it was considered a smooth intubation. Determination with this method revealed that TimeEI50 and TimeEI95 for the sevoflurane/halothane groups were 147/214 s and 194/255 s, respectively. In conclusion, it is possible to determine TimeEI using an inspired sevoflurane concentration of 5% and halothane 2.5% in oxygen. The technique with 5% sevoflurane seems more practical for paediatric anaesthesia induction in busy clinical situations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral pathology & medicine 26 (1997), S. 0 
    ISSN: 1600-0714
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A case of extravasation mucocele showing an unusual intraluminal globular organization of the mucous content is described. The cystic lesion was obtained from the lower lip of a 10-year-old Japanese girl and presented as a painless swelling of 1 year duration. Histologically. the cyst cavity was filled with round globules and encapsulated by a granulation tissue wall devoid of a lining epithelium. To our knowledge, this peculiar histological pattern has not been previously described in an oral mucocele. Clinicopathological features of ‘myxoglobulosis of the appendix’, a morphological variant of appendiceal mucocele, appear to be related to the present case.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 26 (1999), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this article is to review the literature concerning the ideal chewing pattern for best chewing performance. We conclude that at this time there is not one ideal chewing pattern which can be used clinically or in research to assess the health of the mastication apparatus nor to predict chewing performance. It is clear that human masticatory behaviour is one of the most complex human behaviours. Chewing is under the control of the central pattern generator located in the brain stem but is influenced by dental and temporomandibular joint morphology. The most important portion of the chewing cycle is the area entering and leaving the intercuspal position where gliding contacts occur. Maximal chewing capability will likely occur when the chewing pattern follows the dental anatomy unique to the individual. The chewing cycle appears to increase the lateral component of its movement when increased chewing efficiency is required. These situations include increased hardness or the size of bolus, the position of the bolus and the results of the proceeding chewing stroke. The chewing pattern for any one cycle is influenced by a number of factors, thus it is not surprising that the question of the ideal chewing pattern remains unresolved.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 23 (1996), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary A new system for measuring threedimensional deformation has been developed. The main components of the system are a fixed TV camera and vertically scanning projectors. The advantages of the system are: (1) since there is no mechanical contact between the object and the sensing unit, hardness and form of the object do not have to be considered; (2) the system does not need any precise geometry except for the reproducibility of the vertical scanning stage; (3) the time required for one measurement is extremely short; and (4) the system is not expensive. From the basic experiments for testing accuracy, this system has about ± 30 μm range deviation against 1000 μm deformation of the object. The system has been applied to investigate the influence of various impression procedures for a removable partial denture on the displacement of the simulated soft mucosal tissue. It is revealed that deformation forms are expressed precisely. Our results suggest that this measurement system is quite useful for research in dentistry and that it could be widely applied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 24 (1968), S. 960-966 
    ISSN: 1600-5740
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 21 (1966), S. 350-358 
    ISSN: 0001-5520
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1572-8838
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Notes: Abstract Polyaniline (PANI)-poly (p-styrenesulfonic acid) (PSS) composite was prepared by thermal post-polymerization of PANI-p-styrenesulfonic acid (SSA) composite. A PANI–SSA composite was prepared by mixing PANI/N-methyl-2-pyrrolidinone solution with SSA aqueous solution. The PANI–SSA composite film was prepared by casting the composite onto an ITO glass plate. The cast film was converted to PANI-PSS film by heating at 100°C for 3h (post-polymerization process). The PANI–PSS modified ITO electrode showed electrochemical responses based on the redox reaction of PANI–PSS composite in the organic electrolyte solution, for example, propylene carbonate containing 1moldm−3 LiClO4. The PANI–PSS composite was a cation -doping polymer composite. The composite was also modified on a porous carbon material (Reticulated Vitreous CarbonTM, RVC, Energy Research and Generation, Inc.). The PANI–PSS modified RVC electrode showed similar electrochemical behaviour as the PANI–PSS modified ITO electrode. Model secondary lithium cells, Li|1moldm−3 LiClO4-propylene carbonate|PANI–PSS modified RVC electrode, were constructed and charge–discharge cycling tests were carried out. The cell showed about 60% coulombic efficiency under high current density cycling conditions (3.8Ag−1, per gram of PANI–PSS modified RVC electrode).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Cellular and molecular life sciences 24 (1968), S. 1079-1080 
    ISSN: 1420-9071
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Zusammenfassung Eine neue Methode der Peptidsynthese, z.B. von Carnosin, GlySer, GlyGly, LeuTyr und GlyPhe mit Ionenaustauschharzen als Katalysatoren wird beschrieben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Anatomy and embryology 199 (1999), S. 519-527 
    ISSN: 1432-0568
    Keywords: Key words Morphology ; Embryo culture ; Lipid droplet ; Development
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  The ultrastructure of bovine morulae and blastocysts developed from in vitro-matured and -fertilized oocytes in a serum-supplemented medium was compared with that of morulae and blastocysts collected non-surgically from superovulated cows. In the in vivo-derived morulae, two characteristic cells types could be identified by the electron-density of their cytoplasm and by their ultrastructural features. One type appeared light in color with low electron-dense cytoplasm. These cells were located in the peripheral layer of the cluster of blastomeres, possessed numerous cellular organelles such as mitochondria and Golgi apparatus and had microvilli projecting into the perivitelline space. The other cell type was distinguished by cytoplasm that stained more densely than that of the lighter-appearing cells. The darker-appearing cells generally possessed fewer organelles than the lighter cells, but many lysosome-like structures were present in the cytoplasm. The in vitro-developed morulae also contained two types of cells similar to those observed in the in vivo morulae. However, most of the in vitro-developed cells possessed numerous lipid droplets and contained fewer lysosome-like structures than the cells of the in vivo-derived morulae. The blastocysts, both in vivo and in vitro, showed a clear differentiation of trophoblast cells and inner cell mass (ICM)-cells. In the in vivo-derived blastocyst, the apical membrane of trophoblast cells was covered with large, numerous microvilli and well-developed junctional complexes were observed. Lipid droplets were present in the cytoplasm of trophoblast and ICM-cells but were not abundant. In vitro-developed blastocysts showed less well-developed junctional complexes between trophoblast cells, less well-developed apical microvilli on the trophoblast cells, and contained large numbers of lipid droplets. This accumulation of lipid droplets was higher in the trophoblast cells than in the ICM-cells. The zonae pellucidae of in vitro-developed embryos were thinner than that of the in vivo-derived embryos. This study demonstrates conspicuous differences in the ultrastructural features between the in vivo-derived and in vitro-developed embryos, suggesting that the ultrastructure may reflect the various physiological anomalies observed in previous studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...