Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of organic chemistry 31 (1966), S. 1534-1538 
    ISSN: 1520-6904
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 10 (1971), S. 2759-2763 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1436-2449
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Five samples of Poly (vinylidene fluoride) with a molecular weight from 45,000 to 260,000 were analyzed by means of FT-IR spectroscopy in order to study the influence of molecular weight $$\left( {\bar Mv} \right)$$ on the crystallization process. The spectra of films obtained from methylethylketone solutions revealed the prevalence of form II (α) in the case of lower $$\bar Mv$$ and of form III (γ) in the higher molecular weight samples. The amount of form III was found to increase as the Mv decreased and as annealing temperatures increased. The deconvolution technique of vibrational spectra allowed detection of small amounts of other forms accompanying the prevailing one.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 94 (1988), S. 139-141 
    ISSN: 1436-5073
    Keywords: FT-IR microspectrometry ; leukemia ; lymphocytes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The infrared spectra of single human normal and leukemic lymphocytes have been obtained by means of the microscope-FT-IR system. Substantial differences between the two kinds of cells have been observed at level of the O-P-O vibrations of the DNA and of the proteic components. This determination opens up the possibility in determining the early stages of leukemia, in following the course of patients under therapy, and in evaluation of the residual neoplastic disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1436-2449
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Summary Terephthalate copolyesters containing ethylene glycol and either tetramethylene, TMG, or hexamethylene, HMG, glycol and p-oxybenzoate, OB, units were investigated by DSC and IR spectroscopy for the relationship between composition and thermal transitions. Copolymers containing more than 30 mole% OB units showed melt birefringence indicative of thermotropic liquid crystalline behaviour. The IR results were applied quantitatively by plotting optical densities as a function of temperature over the melting range of the copolyesters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0006-3525
    Keywords: fourier transform ir spectroscopy ; protein conformations ; cytochrome C ; Langmuir-Blodgett film ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A qualitative and quantitative analysis of the conformation of Langmuir-Blodgett (LB) dried films of cytochrome C on silicon wafers was performed by Fourier transform ir (FTIR) spectroscopy. A deconvolution procedure was applied to the amide I band analysis, in order to determine the percentage of the different secondary structures. Qualitative analysis was performed by examining difference spectra.Films obtained by spreading protein solutions at pH 7.4 and 1, dried at 25 and 100°C, on silicon wafers were also examined in order to detect spectral components associated with denatured protein domains, and to compare them with cytochrome C LB films.FTIR spectroscopy showed that the following important changes characterise LB film spectra: (a) the α-helix component is higher (its percentage is 57 and 54%) than the one estimated in dried film obtained by spreading the solutions at pH 7.4 on a silicon substrate (43%), (b) there is an increase in the intensity of bands attributed to protonated carboxy group bands, involved and not involved in the formation of hydrogen bonds, and a decrease in those attributed to deprotonated carboxy groups, (c) the intensity of several bands attributed to aromatic amino acids and aliphatic chains increases, and (d) bands due to O(SINGLEBOND)H stretching vibrations of crystallization water are present.These conformational changes could be induced by protein-protein interaction caused by the close packing of molecules that occurs during LB film formation; it cannot be excluded that they may be accompanied by partial changes in the tertiary structure of the protein. A preferential orientation of protein molecules in LB films is also a possibility. © 1997 John Wiley & Sons, Inc. Biopoly 42: 227-237, 1997
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 409-421 
    ISSN: 0886-9383
    Keywords: Deconvolution ; FT-IR spectroscopy ; Protein conformations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In a variety of spectroscopic techniques the fundamental problem exists of determination of the individual spectral components, intrinsically overlapped in the measured spectrum. This is a typical deconvolution problem and several methods and techniques have been proposed for its solution in the technical literature, but suggestions of new approaches are still of interest. A new deconvolution procedure is presented here based on the use of the conjugate gradient minimization algorithm with the addition of sutiable constraints directly obtained by the application to the measured spectrum of the second-derivative operator or more sophisticated resolution enhancement procedures. Since in the examined case deconvolution essentially requires the minimization of a non-convex function, the use of such constraints is extremely important to supply suitable input parameters to the conjugate gradient algorithm to avoid obtaining minimum points which have no physical meaning. In our case each spectral compoent used for deconvolution has been assumed to have a Gaussian analytical definition fully identified by three parameters (amplitude, central frequency, spectral bandwidth), so that the input values required to start the deconvolution process are the number M of Gaussian components and 3M suitable initial approximations of the parameters above. It is shown that all this information can be obtained from the measured data. The deconvolution procedure was implemented by a FORTRAN Microsoft Version 5.1 program and experimental results relative to spectroscopic data obtained by FT-IR analysis of human serum albumin are reported. The results are discussed and compared with data obtained by the use of other techniques.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The secondary structure of human fibrin from normal donors and from bovine and suilline plasma was studied by Fourier transform ir spectroscopy and a quantitative analysis of its secondary structure was suggested. For this purpose, a previously experimented spectrum deconvolution procedure based on the use of the Conjugate Gradient Minimisation Algorithm with the addition of suitable constraints was applied to the analysis of conformation-sensitive amide bands. This procedure was applied to amide I and III analysis of bovine and suilline fibrin, obtained industrially, and to amide III analysis of human fibrin clots. The analysis of both amide I and III in the first case was useful in order to test the reliability of the method. We found bovine, suilline, and human fibrin to contain about 30% α-helix (amide I and III components at 1653 cm-1, and 1312 and 1284 cm-1, respectively), 40% β-sheets (amide I and III components at 1625 and 1231 cm-1, respectively) and 30% turns (amide I and III components at 1696, 1680, 1675 cm-1, and 1249 cm-1, respectively). The precision of the quantitative determination depends on the amount of these structures in the protein. Particularly, the coefficient of variation is 〈 10% for percentage values of amide I and III components 〉 15 and 5%, respectively. The good agreement of our quantitative data, obtained separately by amide I and amide III analysis, and consistent with a previous fibrinogen (from commercial sources) study that reports only information about fibrin β-sheet content obtained by factor analysis, leads us to believe that the amounts of secondary structures found (α-helix, β-sheets, and turns) are accurate. © 1997 John Wiley & Sons, Inc. Biopoly 41: 545-553, 1997.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new deconvolution procedure was applied to the analysis of Fourier transform in spectra of human serum albumin secondary structure in the native state and in states denatured by heat and acid treatment. The deconvolution method is based on the use of the Conjugate Gradient Minimization Algorithm, with the addition of suitable constraints directly obtained by the application to the measured spectrum of the second derivative operator. This method computes central band frequency, bandwidth, and amplitude of the different spectral components of conformation-sensitive amide bands. In the specific case, it was applied to analysis of the amide I band, and the quantitative determination of the different secondary structures (α-helix, β-sheet, β-turns, and random) was attempted for all the samples examined.The precision of the quantitative determination depends on the amounts of these structures present in the protein. The coefficient of variation is 〈10% for values of amide I component 〉15%. The accuracy was tested by comparing, by means of linear regression, the results obtained for human serum albumin, hemoglobin, α-chymotrypsin, and cytochrome c, using our method, with those obtained by x-ray crystallography and CD; the results obtained by other vibrational spectroscopic approaches were also compared. The fit standard error between x-ray and ir secondary structure values estimated by our method is 2.5% for α-helix, 7.16% for β structures, and 5.1% for other structures (turns and random coils).Quantitative results are given for the secondary structures (α-helix, turns, and β-strands) present in the native state (turns and β-strands up to now unknown in aqueous solution), together with the percentages of these structures and additional ones (random coils and β-sheets) formed during denaturization. © 1996 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...