Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (60)
Material
  • Electronic Resource  (60)
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 40 (1999), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Many of the chemicals in common use possess, to some degree, a capacity to cause skin sensitization. Consequently, it is important to conduct a thorough and accurate risk assessment when it can be anticipated that such chemicals are likely to come into contact with human skin. Such risk assessments must consider the nature and extent of dermal exposure together with the sensitizing potency of the chemical. Whilst the exposure elements of the risk assessment process are often well understood, or can at least be reasonably predicted on the basis of the proposed usage of the chemical, the determination of skin sensitizing potency may be problematic. In this paper, we describe an approach to the determination of relative potency of 3 isothiazolinone biocides. Initially, the local lymph node assay (LLNA) provides an estimate of relative sensitizing potency. Where appropriate, this can be followed by confirmatory testing in the human repeat insult patch test (HRIPT). The data generated reveal that (chloro)methyl isothiazolinone (CMI) is a significantly stronger sensitizer than either methyl trimethylene isothiazolinone (MTI) or benzisothiazolinone (BIT). Furthermore, both the LLNA and the HRIPT data show consistently that BIT is a somewhat weaker skin sensitizer than MTI. As an important additional component of the safety evaluation, the ability of these sensitizing isothiazolinones to cross-react has been considered; the data indicate that the more weakly sensitizing isothiazolinones do not elicit allergic reactions in subjects sensitized to MCI. The implications for use of these biocides in various product types are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The potential antagonistic effects of Ca2+, Cu2+, Fe2+, Mg2+, Mn2+ and Zn2+ on contact allergy to Co2+ and Ni2+ were studied. The immune response was characterized by the Co2+ or Ni2+ mediated cellular [methyl-3H]thymidine uptake in peripheral blood mononuclear cell (PBMC) cultures from 6 subjects contact-allergic to Co2+ and Ni2+ and 6 non-allergic control individuals. Results from the in vitro experiments were further evaluated with Co2+-sensitized guinea pigs according to the modified Freund's complete adjuvant test. Ni2+ and Co2+ (10–50 μM) significantly increased the lymphocyte proliferation in PBMC cultures from contact-allergic subjects in comparison with those from control individuals. Pretreatment of the PBMCs with Ca2+, Fe2+, Mg2+ (10–100 μM) or Mn2+ (1–10 μM) did not influence, while Zn2+ (100 μM) enhanced, and Cu2+ (5 and 10 μM) markedly reduced the Ni2+ and Co2+ mediated cellular [methyl-3H]thymidine uptake. The inhibition of the Ni2+- and Co2+-induced cell proliferation by Cu2+ in vitro was probably related to toxicity, since the viability of the cells was significantly reduced by applied combinations of Ni2+ or Co2+ with Cu2+. Topical pretreatment of Co2+-sensitized guinea pigs with maximum non-irritating doses of CuCl2· 2H2O (0.8%) did not affect the challenge testing to CoCl2· 6H2O (0.1 and 0.3%). In conclusion, our combined in vitro and in vivo results indicate that Ca2+, Cu2+, Fe2+, Mg2+, Mn2+ and Zn2+ are not able to antagonise the formation of Ni2+ and Co2+ antigens.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 39 (1998), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 37 (1997), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 6 (1980), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 5 (1979), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 30 (1994), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A cross-sectional study on 353 routine office workers was performed in order to investigate relationships between skin diseases, signs or reported symptoms and work at visual display terminals. Skin diseases and signs were ascertained by dermatological examination. Skin symptoms as well as details of VDT work and other work conditions were obtained from a questionnaire. Measurements of the physical environment were made at each work place. The results were subjected to a multivariate analysis, There was a tendency for increased occurrence of seborrhoeic eczema, nonspecific erythema and symptoms among VDT compared to non-VDT users. Organizational conditions during VDT work, such as a perceived high work pace or work load, and inability to take rest breaks, were found to be associated with reported skin symptoms and nonspecific erythema. A low relative humidity was associated with a diagnosis of seborrhoeic eczema. No associations were found in this study between current field levels of electric or magnetic fields and skin diseases, signs or reported symptoms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 27 (1992), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 25 (1991), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In an attempt to define the optimal test concentration for isothiazolinones. 200 and 100 ppm of 5-chloro-2-methyl-4 isothiazolin-3-one 2-methyl-4-isothiazolin 3-one (MCI/MI) in aq. Solution were tested simultaneously in 918 consecutive eczema patients. 3.4% were positive to 200 ppm and 1.7% to 100 ppm. Indicating that up to 50% of the cases might have been missed. Among the 33 cases with positive reactions, 21 showed stronger reactions to 200 than to 100 ppm, while 9 had reactions of the same strength. Use testes were carried out in 7 cases, of which 2 were positive. MCI/MI plus other allergens), the outcome of the use tests and the optimal test concentration. Our present strategy is to use 200 ppm as an indicator and then to carry out serial dilution and use tests in each “positive” case.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 19 (1988), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: 30 patients who had experienced contact urticaria after exposure to gloves, contraceptives, balloons or dental cofferdams went through a detailed examination including interviews on: exposure to rubber: local and distant symptoms; provocation test; skin prick tests with (among other substance) latex extracts from the rubber tree Hevea brasiliensis patch testing. IgE and RAST analyses, 23 patients (77%) reported additional symptoms from distant organs. 13 belonged to medical occupations: 23 were classified as atopics based on history; 21 had raised IgE-values: 25 were RAST-positive to the extracts from Hevea brasiliensis, 13 had a pre-existing hand dermatitis, of whom 6 were patch test positive to standard allergens. Skin prick tests with extracts from Hevea brasiliensis were the most sensitive diagnostic tool, while the RAST analysis was positive in 25/30 cases. These test and analyses including RAST were negative in 40 control subjects. Provocation tests are of great value, but difficult to standardize. Several patients reported severe reactions at medical and dental examination/treatment situation(surgical gloves, dental cofferdams), and the risk of life-threatening anaphylactic reactions is emphasized.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...