Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (8)
  • 1990  (8)
  • 1
    ISSN: 1744-313X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Biology , Medicine
    Notes: Rearrangements of immunoglobulin genes are mediated by highly conserved heptamer and nonamer recombinational signal sequence. Using a protein-blotting procedure, a heptamer and nonamer recombinational signal sequence-specific DNA-binding protein(s) was examined in the nuclear extracts from lymphoid and nonlymphoid cell lines. Nuclear extracts were subjected to SDS-polyacrylamide gel electrophoresis, and transferred by electroblotting to nitrocellulose filters. Then the filters were hybridized to *P-labelled synthetic double-stranded heptamer-23bp-nonamer or nonamer- l2bp-heptamer recombinational signal sequence probes. A relatively large amount of a DNA-binding protein(s) of M, 115,000 for both probes was detected in the nuclear extracts from immature B and immature T cell lines. No DNA-binding proteins were detected in a myeloma cell line. Interestingly, this DNA-binding protein(s) might be able to recognize both heptamer and nonamer. Recombinational signal sequence-specific DNA-binding activity of the protein(s) and the presence of the protein(s) in a stage-specific manner strongly suggest that the protein(s) of M, 115,000 detected here may play an important role in the recombination of Ig and TCR genes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A broadband reflectometric system in O-mode operation has been developed for the density profile determination, MHD and turbulent fluctuation measurement, and evaluation of the particle diffusion coefficient in the JT-60 tokamak. For the profile determination, full Ka-Q band frequencies of BWOs have been swept in 750 μs, in order to minimize the effect of Doppler shift due to the fluctuation of reflection layers. The heterodyne fixed-frequency reflectometer has unveiled its effectiveness to probe MHD activities, diagnosing the m=1 tearing mode oscillations. It has also enabled the observation of the dramatic suppression of edge plasma density fluctuations at the L to H-mode transition in the LHCD limiter plasma. Furthermore, the propagation delay of density pulses has been observed by different fixed-frequency channels during a series of sawteeth, from which the particle diffusion coefficient was evaluated, with a newly proposed method applicable to fully diffusive plasmas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 3524-3527 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A broadband reflectometric system in O-mode operation has been developed for the density profile determination, MHD and turbulent fluctuation measurement, and evaluation of the particle diffusion coefficient in the JT-60 tokamak. For the profile determination, full Ka-Q band frequencies of BWOs have been swept in 750 μs, in order to minimize the effect of doppler shift due to the fluctuation of reflection layers. The heterodyne fixed-frequency reflectometer has unveiled its effectiveness to probe MHD activities, diagnosing the m=1 tearing mode oscillations. It has also enabled the observation of the dramatic suppression of edge plasma density fluctuations at the L- to H-mode transition in the LHCD limiter plasma. Furthermore, the propagation delay of density pulses has been observed by different fixed-frequency channels during a series of sawteeth, from which the particle diffusion coefficient was evaluated, with a newly proposed method applicable to fully diffusive plasmas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 56 (1990), S. 1445-1447 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Polycrystalline silicon has been grown by ArF excimer laser (193 nm) induced dissociation of Si2H6 adsorbed on a quartz substrate cooled to −69 °C. Silicon atomic layer growth has also been achieved by controlling the Si2H6 adsorbed layer thickness. It is found that the chemical reactivity of the first one monolayer of Si2H6 in contact with the growing Si surface is extremely high compared to that of the second or third Si2H6 layer. The effective photodissociation reaction rate at 193 nm for the first Si2H6 layer is estimated to be more than 40 times faster than that of an isolated Si2H6 molecule. Such high reactivity of the first monolayer is a possible mechanism of the self-limiting process in the atomic layer growth.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 46 (1990), S. 970-972 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 46 (1990), S. 1193-1195 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 46 (1990), S. 1195-1197 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 28 (1990), S. 317-324 
    ISSN: 1741-0444
    Keywords: Automatic calibration ; Eye movement ; Infra-red light ; Line-of-sight displacement ; Photoelectric limb tracking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent reinforced plastic goggle affording a wide view and excellent safety. A small case is provided for the eye-movement detecting circuit and the camera controller unit etc. Its weight is only 1·2 kg and one can easily participate in sports activities while wearing it. Eye-movement data are transmitted with the VHF video signal. The receiver, which analyses the eye movements and processes the TV image, is also compact and easy to carry. The calibration is automatic and completed within 1 min with a high degree of accuracy. By showing the tennis player's line of vision as an example, we were able to obtain good results with application in broadcasting programmes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...