  • 1
    ISSN: 1432-0428
    Keywords: 32–33 splet-proinsulin ; Total cholesterol ; high density lipoprotein cholisterol ; plasminogen activator inhibitor ; Blood pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Standard radioimmunoassay for insulin may substantially overestimate levels of insulin because of cross-reaction with other insulin-like molecules. We have measured concentrations of insulin, intact proinsulin and 32–33 split proinsulin using two-site monoclonal antibody based immunoradiometric assays, and of insulin by a standard radioimmunoassay (“immunoreactive insulin”) in 51 Type 2 (noninsulin-dependent) diabetic subjects in the fasting state. The relationships of these concentrations were sought with those of total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol, triglyceride, plasminogen activator inhibitor, blood pressure, and indices of body fat distribution. Significant relationships were apparent between concentrations of “immunoreactive insulin” as measured by standard radioimmunoassay and triglyceride (r s=0.42, p〈0.001), total cholesterol (r s=0.25, p=0.038), high density lipoprotein cholesterol (r s=−0.30, p=0.018) and body mass index (r s=0.30, p=0.017), but only the relationships with triglyceride (r s=0.36, p=0.006) and body mass index (r s=0.26, p=0.034) remained significant when concentrations of immunoradiometrically measured insulin were employed. Concentrations of 32—33 split proinsulin, which comprises the major insulin-like molecule in these subjects, correlated positively with triglyceride (r s=0.33, p=0.009), total cholesterol (r s=0.23, p=0.050), and plasminogen activator inhibitor (r s=0.26, p=0.049), and negatively with high density lipoprotein cholesterol (r s=−0.29, p=0.021). Concentrations of “immunoreactive insulin” and immunoradiometric assay insulin showed significant positive correlaion with both systolic (r s=0.24, p=0.044 and r s=0.29, p=0.020 respectively), and diastolic blood pressure (r s=0.48, p〈0.001 and n=0.42, p=0.001 respectively), while those of intact proinsulin and 32–33 split proinsulin correlated only with diastolic blood pressure (r s=0.33, p=0.009 and r s=0.31, p=0.014 respectively). Using multiple regression analysis, and including age, sex, race and body mass index in the analyses, concentrations of intact proinsulin and 32–33 split proinsulin, but not immunoradiometric assay insulin, were significantly related to diastolic blood pressure. When all three molecules were incorporated into a single model, only 32–33 split proinsulin was related to diastolic blood pressure (F-change=6.91, [5,43 degrees of freedom]; p=0.012). Thus, high concentrations of insulin-like molecules are associated with changes in recognised cardiovascular risk factor in patients with Type 2 (non-insulin-dependent) diabetes mellitus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Diabetologia 33 (1990), S. 631-634 
    ISSN: 1432-0428
    Keywords: Acute phase insulin response ; first phase insulin response ; intravenous glucose tolerance test ; reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary To determine the reproducibility of the first phase insulin response to intravenous glucose, ten normal subjects underwent two intravenous glucose tolerance tests separated by at least two weeks. Intravenous dextrose (0.3 g/kg) was administered over 2 min by continuous infusion and arterialised-venous samples were taken from a retrogradely cannulated hand vein in the opposite arm. Within subjects, median coefficient of variation for the 3 min insulin was 4.0% (range 1.2–24.3%) and median coefficient of variation for the 0–10 min area was 6.7% (range 1.7–18.8%). These coefficients of variation are close to those of the assay itself (〈 10%). Despite this, between subject responses varied by greater than sixfold. In conclusion, contrary to previous reports the intravenous glucose tolerance test is highly reproducible. This makes it a very valuable tool for further studies of the pathogenesis of diabetes.
    Type of Medium: Electronic Resource