Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (4)
  • 2003  (4)
Material
Years
  • 2000-2004  (4)
Year
  • 1
    Electronic Resource
    Electronic Resource
    [s.l.] : Macmillian Magazines Ltd.
    Nature 423 (2003), S. 965-968 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The effect of ‘colossal magnetoresistance’ (CMR) in hole-doped manganites—an abnormal decrease of resistivity when a magnetic field is applied—has attracted significant interest from researchers in the past decade. But the underlying mechanism for the CMR phenomenon is ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  In the present study, the compositional changes and knoop hardness of the cavity floor prepared by Er,Cr:YSGG laser irradiation was compared with that of the conventional bur cavity. Fifteen laser and 15 bur cavities were cross-sectioned, and subjected to atomic analysis by SEM-EDX and knoop hardness test. Statistical analyses were performed using the Mann–Whitney U-test; a value of P 〈 0·01 was considered significant. Surface characteristics of the prepared cavities were also investigated by light microscopy and scanning electron microscopy (SEM). The results showed that the quantities of Ca (Ca weight %) and P (P weight %) were increased significantly in the laser cavity floor but no significant differences were found between the Ca/P ratio and knoop hardness number of laser and bur cavities. The SEM observation revealed that the lased cavity surface was irregular and there was also the absence of a smear layer; the orifice of dentinal tubules was exposed. Er,Cr:YSGG laser device is considered as one of the most effective and safe devices for cavity preparation because of its many advantages. This includes easy delivery system, minimal thermal damage to the surrounding tissues, minimal thermal-induced changes of dental hard tissue compositions, and favourable surface characteristic.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science, Ltd
    Fatigue & fracture of engineering materials & structures 26 (2003), S. 0 
    ISSN: 1460-2695
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Murakami and Endo have used the 〈inlineGraphic alt="inline image" href="urn:x-wiley:8756758X:FFE0636:FFE_0636_m102" location="equation/FFE_0636_m102.gif"/〉 parameter to successfully predict the endurance limits and the threshold levels for components, which contain small defects or cracks. The present paper uses a modified linear–elastic fracture mechanics (LEFM) approach to examine the mechanistic basis for these correlations. The modifications include consideration of the endurance limit rather than the threshold level as a factor controlling fatigue crack growth in the very short crack growth range, consideration of elastic–plastic behaviour, and consideration of the role of crack closure in the wake of a newly formed crack. Predictions based upon the modified LEFM behaviour are found to be consistent with the earlier predictions of Murakami and Endo.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science, Ltd
    Fatigue & fracture of engineering materials & structures 26 (2003), S. 0 
    ISSN: 1460-2695
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: The fatigue crack growth behaviour of 0.47% carbon steel was studied under mode II and III loadings. Mode II fatigue crack growth tests were carried out using specially designed double cantilever (DC) type specimens in order to measure the mode II threshold stress intensity factor range, ΔKIIth. The relationship ΔKIIth 〉 ΔKIth caused crack branching from mode II to I after a crack reached the mode II threshold. Torsion fatigue tests on circumferentially cracked specimens were carried out to study the mechanisms of both mode III crack growth and of the formation of the factory-roof crack surface morphology. A change in microstructure occurred at a crack tip during crack growth in both mode II and mode III shear cracks. It is presumed that the crack growth mechanisms in mode II and in mode III are essentially the same. Detailed fractographic investigation showed that factory-roofs were formed by crack branching into mode I. Crack branching started from small semi-elliptical cracks nucleated by shear at the tip of the original circumferential crack.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...