Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (1)
  • 1975-1979  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 14 (2000), S. 134-136 
    ISSN: 1432-2218
    Keywords: Key words: Hyperhidrosis — Repeat sympathectomy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Patients undergoing an unsuccessful sympathectomy experience dryness on one hand and excessive sweating on the other. This is embarrassing for the patients, and resolution of both a previous failed sympathectomy and recurrent hyperhidrosis is important. Methods: From September 1995 to January 1998, 24 patients (11 men and 13 women; mean age, 28.2 years) underwent repeat transthoracic sympathectomy (TES). The repeat TES was performed with patients under general anesthesia using either a standard single-lumen endotracheal tube (12 patients) or a double-lumen endotracheal tube (12 patients). Ablation of T2 and T3 ganglia and any Kuntz fiber was performed in treating patients with palmar hyperhidrosis, and a similar procedure was performed on T3 and T4 ganglia for patients with axillary hyperhidrosis. Results: The reasons for failure of the previous TES were pleural adhesion (14/24), intact T2 ganglion (5/24), aberrant venous arch drainage to the superior vena cava (2/24), incomplete interruption of sympathectic nerve (2/24), and possible reinnervation (1/24). The mean operation time was 28 min (range, 18–72 min). In all, 23 patients had a satisfactory result, without recurrence of palmar or axillary hyperhidrosis. The mean follow-up time was 22 months (range, 5–30 months). The average hospital stay was 1.8 days. There was no surgical mortality. Conclusion: Repeat TES is a safe and effective method for treating both an unsuccessful sympathectomy and recurrent palmar or axillary hyperhidrosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 18 (1976), S. 1557-1572 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Tower cycling fermentors for the production of single-cell protein from volatile substrates were studied. The mass transfer, mixing and circulation patterns, and residence time distribution (RTD) curves were investigated in these vessels. This study suggests that the tower cycling fermentors for volatile substrates fermentation may improve product yields and at the same time reduce the power consumption, thereby resulting in a significant increase in operating cost savings and capital profits. The results of this research further indicate a future potential for commercial scale tower cycling fermentors.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...