Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Zoomorphology 32 (1937), S. 276-288 
    ISSN: 1432-234X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Internist 41 (2000), S. 205-207 
    ISSN: 1432-1289
    Keywords: Schlüsselwörter HCC ; Perkutane Ethanolinjektion ; Kryotherapie ; Review
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zum Thema Die Prognose des häufig von einer Leberzirrhose begleiteten hepatozellulären Karzinoms (HCC) ist ungünstig. Da nur ein geringer Prozentsatz der Patienten durch Resektion oder Transplantation therapierbar ist, fällt in Ermangelung einer potenten Chemotherapie den lokal destruierenden Verfahren eine wichtige Rolle bei der Behandlung zu. Die perkutane Ethanolinjektion (PEI) erzeugt durch die intratumorale Injektion von Ethanol eine Gewebsnekrose. Das Verfahren der Kryotherapie führt durch Einfrieren und Auftauen zur Gewebsdestruktion. Bei entsprechender Selektion kann durch beide Verfahren eine komplette Tumordestruktion mit Langzeitüberleben erreicht werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Der Internist 41 (2000), S. 198-204 
    ISSN: 1432-1289
    Keywords: Schlüsselwörter HCC ; Chemoembolisation ; Radiofrequenzablation ; Laser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zum Thema Die transarterielle Chemoembolisation (TACE) wie auch die Thermoablationen sind Methoden, die bei der palliativen Therapie des hepatozellulären Karzinoms (HCC) zum Einsatz kommen. Während die TACE auf einer Zellzerstörung durch die Kombination von Zytostatika und Gefäßokklusion basiert, wird mit der Thermoablation eine hitzeinduzierte Gewebenekrose bei Temperaturen um ca. 60°C erreicht. Der Artikel beschäftigt sich mit den technischen Aspekten und klinischen Indikationen der TACE, der Lasertherapie und der Radiofrequenz(RF)-Ablation. Insbesondere für die letzteren Methoden erscheint eine adäquate Bildgebung zur Steuerung und Überwachung der Therapie indiziert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 232 (1970), S. 256-267 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Time differentialγγ-angular correlation measurements have been performed to determine the electric interaction of the 2.3 MeVI=5− state of120Sn in different polycristalline antimony compounds. A calibration of the field gradient was achieved by Mößbauerexperiments with the 23.8 keVI=3/2+ state in119Sn using identical sources. From the ratio of the measured electric interactions the ratio of the quadrupole moments is deduced as: $$\left| {\frac{{Q(2.3{\mathbf{ }}MeV level,{\mathbf{ }}I = 5^ - ,^{120} Sn)}}{{Q(2.8{\mathbf{ }}keV level,{\mathbf{ }}I = {3 \mathord{\left/ {\vphantom {3 2}} \right. \kern-\nulldelimiterspace} 2}^ + ,^{119} Sn)}}} \right| = 2.86(15)$$ . Using 0.06 (2) b for the quadrupole moment of the 23.8 keV level in119Sn one gets for the quadrupole moment of the 2.3 MeV level in120Sn ¦Q(2.3 MeV level,I=5−,120Sn)¦=0.021 (8) b.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The interference of photoeffect and internal conversion following nuclear resonance absorption of 26 keVE1 γ quanta in161Dy has been measured in Mössbauer transmission experiments and by direct detection of re-emitted conversion electrons in a parallel-plate avalanche counter. The ratio of the amplitudes of the interference terms in transmission and scattering experiments was found to be in agreement with the theory. An angular distribution of the interference effect has been observed in the scattering experiments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 259 (1973), S. 323-332 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Mössbauer experiments on57Fe on the giant moment system Ni75-x Fe x Ga25 were performed. For various Fe concentrationsx the hyperfine fields, the isomeric shift, and the quadrupole splitting were measured. A saturation hyperfine field of 223 (2) kOe at the Fe atom substituting a Ga site and of 200 (2) kOe at the Fe atom substituting a Ni site were found.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 248 (1971), S. 370-374 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract TheL-shell conversion coefficient of the 26 keV Mössbauer transition in161Dy has been determined to be αL=2.4 −0.2 +0.3 by coincidence techniques using high resolution Ge(Li) and Si(Li) detectors. With theoretical values for theM- andN-shells the total conversion coefficient is calculated to be αtot=2.9 −0.2 +0.3 .
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Intensivmedizin und Notfallmedizin 37 (2000), S. S063 
    ISSN: 1435-1420
    Keywords: Key words Pulmonary magnetic resonance imaging – 3 dimensional magnetic resonance angiography – pulmonary embolism – contrast enhanced magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary  The purpose of this article is to describe the role of 3 dimensional (3D), breathhold, contrast enhanced magnetic resonance angiography (MRA) in the diagnosis of acute pulmonary embolism. In a volunteer study, two MRA techniques were adopted. One of which enabled acquisition of the pulmonary vasculature in 18 s. The other technique was coupled with a higher spatial resolution, leading to a scan time of 23 s. Additionally, the impact of breathing motion on vessel delineation was assessed. The breathheld 23 second scans revealed excellent image quality and near complete visualization of central and segmental, as well as 81% of subsegmental, pulmonary arteries. Imaging time can be shortened to 18 seconds with only marginal loss in visualization performance (p〈0.05). Respiratory motion was found to cause significant worsening of image quality and vessel detectability. To maintain relevance in a clinical setting, imaging time can be minimized at the cost of a reduction in spatial resolution. According to data available from patient studies, the sensitivity, specificity, positive and negative predictive values of 3D MRA in comparison to conventional angiography amounts to 100, 95, 87, and 100%, respectively. However, breathhold duration and spatial resolution need further optimization if 3D MRA should replace conventional angiography as the gold standard in the future. Conclusion: The preliminary experience suggest that gadolinium-enhanced, three dimensional, breathhold, magnetic resonance angiography shows promise as a safe, rapid, accurate and cost-effective imaging technique for the diagnosis of pulmonary embolism. In combination with its ability to perform deep venous studies and the potential aspect of MR-perfusion studies of the lung parenchyma, pulmonary MRA might in the future turn out to be the “one stop shop” for diagnosing pulmonary embolism.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Journal of pest science 15 (1939), S. 125-128 
    ISSN: 1612-4766
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Journal of pest science 15 (1939), S. 49-51 
    ISSN: 1612-4766
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...