Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (34)
  • 1880-1889  (1)
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 91 (2002), S. 1417-1422 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The average value of the magnetocrystalline anisotropy field, Hk, is an important parameter for the characterization of magnetic recording media but is difficult to measure accurately due in part to the effect of interactions between the grains. In order to evaluate Hk we have studied two model CoCrPtTa magnetic films using a number of complementary techniques: high field ferromagnetic resonance (FMR) (35.0–45.0 kOe), low field (〈20 kOe) vector vibrating-sample magnetometry and torque magnetometry. The FMR measurements were performed at a number of discrete frequencies in the range 75–93 GHz using a new quasi-optical spectrometer developed at the University of St. Andrews. The values of Hk derived by FMR (10.8 kOe) are approximately 10% greater than those obtained from conventional magnetometry (9.6 kOe). This difference is believed to be due to the presence of intergranular exchange coupling which reduces the measured value of anisotropy when the applied field is not sufficiently large to completely align the magnetic moments. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 3016-3023 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A design for a high mass resolution scanning atom probe is described, which utilizes a two-conductor microelectrode held at 10–100 μm from the specimen. Field evaporation pulses are applied to the part of the counter-electrode closest to the specimen, while the output is maintained at ground. If the gap between the two conductors is small, field evaporated ions pass through the microelectrode while the pulse voltage is essentially constant, and thus the resultant spread in ion energies is small and the mass resolution in time-of-flight mass spectrometry is correspondingly improved. Initial results indicate improvements of 4–5 times over the mass resolution obtained with a simple counter electrode. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Clinical and experimental dermatology 28 (2003), S. 0 
    ISSN: 1365-2230
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Child 29 (2003), S. 0 
    ISSN: 1365-2214
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Psychology
    Notes: Background  Visual analogue scales (VAS) are used to assess the strength of perceptions of both children and adults in many clinical and research settings. Although the VAS has been shown by some authors to be reliable for use by children aged 5 years and older, others have proposed that young children, generally ≤ 7 years of age, may not have the conceptual ability to use a VAS.Objective  To identify demographic and cognitive variables that would maximize the accuracy of predicting children's abilities to use a VAS.Methods  Forty kindergarten children performed a seriation task, used a VAS to perform a calibration task and completed the Block Design and Vocabulary subtests of the Wechsler Preschool and Primary Scale of Intelligence – Revised (WPPSI-R). An estimated IQ was calculated from the WPPSI-R subtest scores. Socioeconomic status was assessed using the Hollingshead Four Factor Index of Social Status. Logistic regression was used to determine the best predictive models. Sensitivity, specificity, negative predictive value, positive predictive value and accuracy were calculated for statistically significant predictive models.Main outcome measure  Successful completion of the calibration study by the child.Results  Only 42% of the subjects could use a VAS. The subject's age (≥ 5.6 years), combined with estimated IQ (≥ 100), was the best predictor of a child's ability to use a VAS (88% accuracy).Conclusion  The majority of kindergarten children in our study could not complete a VAS accurately. Cognitive ability, combined with chronological age, was the best predictor of a child's accurate use of a VAS, as determined by logistic regression. Paediatric researchers may need to consider alternative rating scales to measure perceptions in children under 7 years of age.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Fluids 12 (2000), S. 597-602 
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Deposition of a spontaneously-spreading film on a clean water surface creates a front which propagates radially outward from the point of deposition. This rapidly spreading film was used as a tool to quickly change the boundary condition of a water surface from one which is shear-free, to a boundary condition which supports shear. Infrared images of a water surface experiencing evaporative convection were recorded as this film spread. These images were converted to surface temperature fields. The amount of turbulent structure present in these fields changes dramatically across the front. Ahead of the front, significant variations at large and small spatial scales are evident, while behind the front the small scale structures are eliminated. The time scale at which this damping occurs is short and has not been reported on heretofore. In addition to being relevant to free surface turbulence, these results demonstrate the utility of infrared imaging in the study of spreading films.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 78 (2001), S. 2143-2144 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Obliquely deposited metal films which are nearly continuous, displaying several unexpected solar optical properties. Transmittance intensity, spectral character, preferred direction of incidence, and polarization sensitivity, infer processes which effective-medium models based solely on "interior" properties cannot describe. Amplified transmittance through voids around 20 nm wide involving near surface excitations can explain the data. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 107 (2000), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 58 (2003), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 56 (2001), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We investigated the effect of Buscopan® 20 mg, given at the end of surgery, on analgesic requirements in 44 ASA I and II patients presenting as day cases for laparoscopic sterilisation using Filshie clips. Patients were randomly allocated to receive either intravenous Buscopan 20 mg or saline placebo at the end of surgery. There was no significant difference in pain scores, analgesic requirements or the incidence of nausea and vomiting between the two groups. We conclude that intravenous Buscopan 20 mg was not effective for pain relief following laparoscopic sterilisation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Anaesthesia 57 (2002), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Model customisation is used to adjust prognostic models by re-calibrating them to obtain more reliable mortality estimates. We used two methods for customising the Simplified Acute Physiology Score II model for 15 511 intensive care patients by altering the logit and the coefficients of the original equation. Both methods significantly improved model calibration, but customising the coefficients was slightly more effective. The Hosmer-Lemeshow χ2-value improved from 306.0 (p〈 0.001) before, to 14.5 (p 〈 0.07) and 23.3 (p 〈 0.06) after customisation of the coefficients and the logit, respectively. Discrimination was not affected. The standardised mortality ratio for the entire population declined from 1.16 (95% confidence interval: 1.13–1.20, p 〈 0.001) to 0.99 (95% confidence interval: 0.96–1.02, p 〈 0.22) after customisation of the coefficients. The uniformity-of-fit for patients grouped by operative status and comorbidities also improved, butremained imperfect for patients stratified by location before intensive care unit admission. Amalgamation of large, regional databases could provide the basis for the re-calibration of standard prognostic models, which could then be used as a national reference system to allow more reliable comparisons of the efficacy and quality of care based on severity adjusted outcome measures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...