Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (3)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 983-986 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We made an inventory of krypton spectra over the wavelength range 3700–6000 Å for the development of fusion plasma diagnostics. The measurements were performed using a prism spectrometer on the Lawrence Livermore National Laboratory low energy electron beam ion trap (EBIT II). With the electron energy from 150 to 17 000 eV, we recorded low ionization stages together with a number of magnetic dipole transitions from higher charge states. In total, we observed over 80 lines, of which about 70% of the lines have not been listed in the literature. This measurement established a baseline for future extension using spectrometers with very high resolution. As an example, we present the Kr spectra from 3770 to 3900 Å measured with a transmission grating spectrometer that has a resolving power of about 15 000. Among the 41 lines observed, only six lines have been listed in the databases. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 508-512 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A powerful and versatile, simple to use multiparameter data acquisition system has been implemented for use in spectroscopy. In its standard configuration, the system can acquire signal from 16 time-to-digital converter channels, 16 analog-to-digital converter channels, and 12 scaler inputs. The system was put to use on the electron beam ion trap experiment to record the output from four position-sensitive proportional counters in two soft x-ray spectrometers together with the signal from an x-ray pulse height analyzer. Also recorded are the electron beam energy and the pulse height distribution of the proportional counters. All data are recorded as a function of time. Because the relevant parameters are recorded simultaneously, software gates instead of hardware gates are used to select the data of interest. This has led to a substantial cost saving over earlier data acquisition systems. Data are stored in binary or in ascii format for system-independent processing. The operation of the system is demonstrated in a measurement of the M-shell soft x-ray spectrum of gold. We used the system to record the 3–4 and 3–5 transitions of gold (Au44+–Au51+) excited with a simulated Maxwellian with electron temperature of 2.5 keV. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We have mounted 1 μm thick aluminized polyimide windows onto the position sensitive proportional counters employed by the wide-band flat crystal spectrometers at the Lawrence Livermore National Laboratory electron beam ion trap experiment. The aluminized polyimide, supported by thin wires across the short axis of the window, is used to isolate the detection chamber of the proportional counters, which operate at a pressure of 760 Torr, from the vacuum chamber of the spectrometer. The windows are modified versions of those developed for the proportional counters which were used during ground calibration of the Chandra X-ray Observatory. The transmission properties of these windows are, therefore, well known. The increased transmission efficiency of the polyimide windows relative to the 4 μm thick polypropylene window material previously employed by our proportional counters has extended the useful range of the spectrometer from roughly 20 to 30 Å at energies below the carbon edge, as well as increasing detection efficiency at wavelengths beyond the carbon edge. Using an octadecyl hydrogen maleate crystal with 2d=63.5 Å, we demonstrate the increased wavelength coverage by measuring the resonance, intercombination, and forbidden lines in helium-like N VII in two different density regimes. The thin polyimide windows have also increased the efficiency of the spectrometers entire wavelength range. To demonstrate the increased efficiency we compare the Fe XVII spectrum in the 15–17 Å band measured with the 1 μm aluminized polyimide windows to the 4 μm aluminized polypropylene windows. The comparison shows an average increase in efficiency of ∼40%. The polyimide windows have a significantly lower leak rate than the polypropylene windows making it possible to achieve approximately an order of magnitude lower pressure in the spectrometer vacuum chamber which reduces the gas load on the trap region. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...