Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (3)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 89 (2001), S. 7139-7141 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: With better than 1% control of alloy composition, binary alloy films CoxNi1−x/Cu(100) with x≤10% were prepared for the study of the spin-reorientation transition at variations of composition, thickness, and temperature. Only the films with a Co concentration less than 10% reveal the spin-reorientation with the film thickness. The critical thickness for the spin-reorientation transition was shifted drastically from 7.5 to 17.5 monolayers for a Co concentration variation from 0% to 8%. These findings indicate a strong influence of the composition on the magnetoelastic anisotropy. A kind of temperature-driven spin-reorientation from in-plane to perpendicular with increasing temperature was also found. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 89 (2001), S. 7153-7155 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The magnetic and structural properties were investigated for the 2 ML Co/Cu(100) films grown at various temperatures from 125 to 350 K. By precisely controlling the film thickness, the influence of thickness on Curie temperature (TC) due to the finite size effect can be excluded. The Curie temperature of the 2 ML Co keeps almost invariant for the growth temperature (Tg) below 250 K, and drops drastically at Tg higher than 275 K. For Tg=340 K, TC dropped to 170 K which is only about half of 325 K for Tg=125 K. Accompanied with the increase of TC for the films grown at lower temperatures, the remanent Kerr signal as well as coercivity were enhanced. According to a simple theoretical estimation, the change of TC due to the variation of the magnetization and anisotropy was found to be consistent with the experimental results. The enhancement in TC or magnetization and anisotropy with various Tg should be traced back to the presence of island growth in the films grown at lower temperatures. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We conducted a double-blind, randomised, placebo-controlled study evaluating the efficacy of prophylactic metaraminol for preventing propofol-induced hypotension. Thirty patients aged 55–75 years undergoing general anaesthesia were randomly allocated to receive either metaraminol 0.5 mg or saline before administration of fentanyl 1 µg.kg−1 and propofol 2 mg.kg−1. Induction of anaesthesia was associated with a decrease in mean and systolic arterial pressure in both groups (p = 0.0001). However, there was no significant difference between the two groups. These results show that prophylactic use of metaraminol 0.5 mg does not prevent the decrease in blood pressure following fentanyl and propofol induction in older patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...