Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (9)
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high precision atomic polarimeter system for the use in beam-foil spectroscopy experiments with a few keV/amu heavy-ion beams has been developed. The polarimeter measures the circular polarization of fluorescences from the beam ion in-flight after the beam–foil interaction. The present system has two identical such polarimeters in both sides of the beam axis to reduce the systematic errors such due to the fluctuations of beam current, background and so on. A successful use of an ultrathin carbon foil (1.5 μg/cm2), which was durable for several hours against a few hundred nA beam irradiation, enabled the beam–foil experiments with such low energy heavy-ion beams. A performance test of the polarimeter system was carried out in the tilted foil experiments with a 1.7 keV/amu 14N+ beam. The atomic polarization was observed for the transition 1s22s22p3p 1D→1s22s22p3p 1P, whose fluorescence wavelength is 399.5 nm, in the N+ ion (N II). The polarization was approximately −2% for the tilt angle of −40° and showed monotone increasing with increasing tilt angle up to +2% for +40°. The polarization at 0° was (0.002±0.25)%, which is highly consistent with the expected polarization of 0%. This result indicates the high reliability of the present polarimeter system. This is the first tilted-foil experiment at such low beam energy. The present experimental technique will be very useful for studies of the polarization mechanism of the beam–foil interaction. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1440-1797
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: IgA nephropathy (IgAN) is known to commonly cause of end-stage renal failure in Japan. The glomerular lesions of IgAN have histological variations. The determination of prognosis and therapeutic strategy should be carefully done by experts because morphological information from renal biopsies using ordinary optical microscopy is usually qualitative and subjective. Moreover, the histological items for the evaluation of glomerular lesions seems to be unsatisfactory for expression of the disease condition of IgAN. The beneficial properties of scanning acoustic microscopy (SAM) include not only observation of microstructure but also quantitative measurement of acoustic propagation speed (APS), indicating the tissue elasticity. In the present study we compared the APS of glomeruli with the pathological scores that were determined by ordinary light microscopy. We used stocked human renal biopsy specimens diagnosed as IgAN (n = 12) and normal/minimal changes (n = 5). All samples were taken by renal biopsy in Kagawa Medical University Hospital during 1997–2000 under informed consent of the patients. The obtained renal tissue were immersed in 10% formalin and embedded in paraffin. A fixed specimen was consecutively cut into 4 μm slices. One of the deparaffinized 4 μm-specimens was directly utilized for SAM without any staining, and the others were stained with haematoxylin-eosin and Masson Trichrome for counting cell number and evaluation of collagen accumulation. For the measurement of glomerular APS, the sample line was set on the equator of the glomerulus and then scanning of the X–Z axis was carried out to obtain the interference fringes that were analysed with a computer imaging software in order to calculate the APS. In light microscopic study, pathological scores were evaluated semiquantitatively by two independent investigators who were unaware of the sample number. Glomerular lesions were scored into five grades and glomerular cell number was also counted in individual glomerulus. The computer-assisted imaging analyser Win ROOF (Mitani, Fukui, Japan) was also used for the determination of glomerular collagen content in specimens stained by Masson Trichrome. A two-dimensional image (C-mode scanning) of SAM enabled imaging of glomerulus in renal biopsy specimen compatible with findings of ordinary light microscopy without staining dye. The glomerular APS in IgAN was significantly higher than in normal/minimal changes. This alteration of glomerular APS in IgAN was positively correlated to both semiquantitative pathological scores and glomerular collagen content determined by light microscopy. However, the cell number of glomelurus did not change between IgAN and normal/minimal change. As a result, we conclude that the glomerular lesion, especially matrix expansion in IgAN, was comparable with the absolute value among specimens. Therefore, it is suggested that SAM method is a novel and useful technique for quantitative evaluation of glomerular lesion in IgAN.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background A recent report provided evidence that a disintegrin and metalloprotease domain 33 (ADAM33), a member of the ADAM family, is a novel susceptibility gene in asthma linked to bronchial hyper-responsiveness. However, there has been no investigation of the genetic role of ADAM33 variants in nasal allergy.Objective The purpose of this study was to test the association between ADAM33 polymorphisms and Japanese cedar pollinosis (JCPsis), a most common seasonal allergic rhinitis in Japan.Methods We conducted a case–control association study among a Japanese population, involving 95 adult individuals with JCPsis and 95 normal healthy controls. A total of 22 single-nucleotide polymorphisms (SNPs) in ADAM33 were genotyped using PCR-based molecular methods.Results Six SNPs of ADAM33 gene, three in introns (7575G/A, 9073G/A and 12540C/T) and three in the coding region (10918G/C, 12433T/C and 12462C/T), were strongly associated with JCPsis (P=0.0002−0.022 for absolute allele frequencies) and most of the SNPs were in linkage disequilibrium with each other. A higher frequency of the common alleles of these SNPs was noted for the subjects with JCPsis in comparison with healthy controls. We also identified a haplotype associated with the disease susceptibility. In addition, associations were found between ADAM33 polymorphisms and various cedar pollinosis phenotypes including clinical severity, eosinophil counts in nasal secretion and allergen-specific IgE levels in sera, but not total serum IgE levels.Conclusion These results indicate that polymorphisms in the ADAM33 gene are associated with susceptibility to allergic rhinitis due to Japanese cedar pollen, but the functional relationship still needs clarification.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of materials science 19 (2000), S. 1303-1304 
    ISSN: 1573-4811
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1573-4811
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of materials science 19 (2000), S. 2223-2224 
    ISSN: 1573-4811
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 243 (2000), S. 657-659 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The solvent extraction behavior of radioiodine at tracer concentration was studied by varying the pH of the tracer solution in order to gain deeper insight into the anomalous behavior of radioiodine at low concentrations. The anomalous behavior of radioiodine was observed with all the tracer solutions because of the existence of radioiodine complex in the tracer solution. The observed anomalous behavior of radioiodine was consistently explained by the comprehensive extraction mechanism.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 243 (2000), S. 631-634 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The solvent extraction behavior of radioioine and astatine has been investigated under various conditions in order to compare the extraction behavior of astatine with radioiodine at tracer concentration. In this study, basic tracer solutions of astatine and radioiodine were extracted into the CS2 solution under various conditions. Astatine existed as a pure species in the tracer solution and formed cationic compound in the acidic solution which was also extracted into the organic solvent instantaneously. On the other hand, radioiodine existed as a complex in the tracer solution and was partly extracted into the organic solvent at tracer concentration. The observed different extraction behavior of astatine and radioiodine were consistently explained by the respective proposed extraction reaction schemes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Superconducting thin films of YBa2Cu3Ox (YBaCuO) and NdBa2Cu3Ox (NdBaCuO) were grown by mist microwave-plasma chemical vapor deposition (MPCVD) using a CeO2 buffer layer on a MgO (001) substrate. In this method, the CeO2 buffer layer was deposited on the MgO (001) substrate at 1173 K by MPCVD. YBaCuO and NdBaCuO films were then grown at 1073 K and 1223 K, respectively. The Tc (zero resistance) values of the YBaCuO and NdBaCuO films obtained with a CeO2 buffer layer were 90.1 K and 94.1 K, respectively, about 10 K higher than those without a CeO2 buffer layer. The surface roughness of the films was less than 5 nm in each case. The interface between the substrate and the grown layer was confirmed to be extremely sharp by Auger profile analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...