Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (2)
  • 1995-1999  (2)
Source
  • Articles: DFG German National Licenses  (2)
Material
Years
Year
  • 1
    ISSN: 1432-2161
    Keywords: Key words Magnetic resonance imaging ; Ultrasonography ; Achilles tendon ; Tendinosis ; Partial rupture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. To compare information gained by ultrasonography and magnetic resonance imaging (MRI) in chronic achilles tendinopathy with regard to the nature and severity of the lesion. Design. Imaging of both achilles tendons with ultrasonography and MRI was performed prior to unilateral surgery. Operative findings and histological biopsies together served as a reference. Patients. Twenty-seven patients (22 men, 5 women; mean age 44 years; 21 athletes) suffering from chronic achilles tendinopathy participated in the study. Eighteen patients had unilateral and 9 had bilateral symptoms. Results and conclusions. Surgical findings included 4 partial ruptures, 21 degenerative lesions and 2 macroscopically normal cases. Microscopy revealed tendinosis (degeneration) in all tendon biopsies, including cases with a partial rupture, but only slight changes in the paratendinous tissues (paratenon). Ultrasonography was positive in 21 of 26 and MRI in 26 of 27 cases. Severe intratendinous abnormalities and a sagittal tendon diameter 〉10 mm suggested a partial rupture. In tendons with a false negative result histopathological changes were mild and a tendency towards a better clinical outcome was noted in the sonographic cases. Assessment of the paratenon was unreliable with both methods. Ultrasonography and MRI give similar information and may have their greatest potential as prognostic instruments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-1421
    Keywords: Gold ; hematite surface ; surface complexation ; adsorption ; potentiometric titration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Geosciences
    Notes: Abstract The acid/base properties of the hematite/water interface and surfacecomplexation with gold has been studied by potentiometric titrations in thefour component system H+ – ≡FeOH –AuCl 4 - – Cl-. Equilibrium measurementswere performed in NaCl media at 298.2 K. In the evaluation of equilibriummodel from experimental data the constant capacitance model was applied. Theacid/base properties were investigated in 0.1 M NaCl in the range 2.6 ≤pH ≤ 7.4. The resulting intrinsic constants for protonation anddeprotonation of hydroxyl groups at the surface were logβ 1,1,0,0(int) s = 7.10 ± 0.06 andlog β -1,1,0,0(int) s = - 7.80 ±0.06. The density of proton active surface sites was 2.85nm-2 and the specific capacitance 2.5 C V-1 m-2. In the investigation of surface complexation of gold, thepotentiometric titrations were performed in the range 2.0 ≤ pH ≤ 10.2.Titration data was supplemented with analysis of Au in the aqueous phase byatomic absorbance spectrometry. The equilibrium model proposed consists ofthe following monodentate surface complexes: ≡FeOHAuCl3(log β 0,1,1,-1 s = 1.45 ± 0.03),≡FeOHAuCl2OH (logβ -1,1,1,-2 s = -3.89 ± 0.02), ≡FeOHAu(OH)3 (logβ -3,1,1,-4 s = -21.94 ± 0.05). Aslightly better fit could be obtained by assuming formation of a bidentatecomplex with the composition(≡FeO)2Au(OH)H2O. However, based onstructural arguments this complex was rejected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...