Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (21)
  • Polymer and Materials Science  (19)
  • Alternating ventilation  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 22 (1996), S. 813-817 
    ISSN: 1432-1238
    Keywords: Alternating ventilation ; Cardiac output ; Central venous pressure ; Intrathoracic pressure ; Lung volume ; Pericardial pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective We tested the hypothesis that mean thoracic expansion (and mean lung volume) is lower during alternating ventilation (AV), i.e. ventilation of both lungs with a phase shift of half a ventilatory cycle, compared to synchronous ventilation (SV) of both lungs. As a consequence, intrathoracic pressure will be lower, causing lower, central venous pressure and higher cardiac output. Design In eight anaesthetized and paralysed piglets, differential ventilation was established by fixation of an endobronchial tube in the left main bronchus. SV and AV were sequentially applied for four and three periods, respectively, of 10 minutes each. Minute ventilation was the same during AV and SV and adapted to normocapnia. Two series of observations were performed: series 1 with intact thorax and monitoring of oesophageal pressure; series 2 after perforation of the sternum, airtight closure of the thorax and monitoring of pericardial pressure. Results In both series, mean lung volume was 16±4% lower and central venous, oesophageal (series 1) and pericardial pressures (series 2) were 0.5±0.7 mmHg lower during AV compared to SV (allp〈0.001). In series 1, aortic pressure was 5 mmHg and cardiac output 8% higher (bothp〈0.001). In series 2, cardiac output was 5% higher during AV (p〈0.001), but aortic pressure did not change (p=0.07). Conclusion Our data verified the hypothesis. The lower oesophageal (series 1), pericardial (series 2) and central venous pressures during AV compared to SV could be explained by the smaller thoracic expansion due to the lower mean lung volume, which was attributed to compression of the opposite lung by the expansion of the inflated lung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 21 (1995), S. 1009-1015 
    ISSN: 1432-1238
    Keywords: Alternating ventilation ; Cardiac output ; Central venous pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective We tested whether alternating ventilation (AV) of each lung (i.e. with a phase difference of half a ventilatory cycle) would decrease central venous pressure and so increase cardiac output when compared with simultaneous ventilation (SV) of both lungs. Theory If, during AV, the inflated lung expands partly via compression of the opposite lung, mean lung volume will be smaller during AV than SV. As a consequence, mean intrathoracic pressure (as cited in the literature), and therefore, central venous pressure will be smaller. Design The experiments were performed in seven anaesthetized and paralyzed piglets using a double-piston ventilator. Minute ventilation was the same during AV and SV. Starting at SV, we alternated three times between AV and SV for periods of 10 min. Results During AV, central venous pressure was decreased by 0.7 mmHg and cardiac output was increased by 10±4.4% (mean, ±SD) compared with SV. AV also resulted in increased arterial pressure. During one-sided inflation with closed outlet of the opposite lung, a pressure rise occurred in the opposite lung, indicating compression. Conclusion The higher cardiac output during AV than SV can be explained by the fact that central venous pressure is lower during AV. This lower central venous pressure is very probably due to the lower mean intrathoracic pressure caused by compression of the opposite lung during unilateral inflation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A rat bone marrow cell culture was used to evaluate the osteogenic potential of amorphous and crystalline thin calcium phosphate (Ca/P) coatings. The coatings were deposited on titanium discs using a radiofrequency magnetron sputter procedure. Amorphous and crystalline plasma spray Ca/P coated and noncoated titanium discs served as reference material. The cellular behavior was analyzed with quantitative (attachment and proliferation rates) and qualitative (scanning electron microscopy) techniques. No significant differences were found in cell attachment and proliferation rates between the various materials. Scanning electron microscopy showed extracellular matrix formation after 18 days of culture on amorphous plasma-sprayed and the two types of magnetron sputtered coatings. Furthermore, no severe degradation of the magnetron sputtered coatings was observed. They even appeared to induce apatite formation. On basis of the results, we conclude that magnetron sputtering appears to be a promising method to manufacture bioactive ceramic coatings. © 1995 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 539-547 
    ISSN: 0021-9304
    Keywords: in vivo ; soft-tissue reaction ; scanning electron microscopy ; confocal laser scanning microscopy ; three-dimensional reconstruction ; implant interface ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width of 2.0, 5.0, and 10.0 μm. All grooves had a depth of approximately 0.5 μm. SEM observation showed fibroblasts, erythrocytes, lymphocytes, macrophages, fibrin, and collagen on all implant surfaces after 3 and 7 days. After 42 and 84 days only little collagen, a small number of fibroblasts, but no inflammatory cells were seen on the implant surfaces. The fibroblasts were not oriented along the surface grooves on all textured surfaces. Three-dimensional reconstruction of CLSM images and LM images showed no significant differences between the thickness of the capsules surrounding the smooth and those surrounding the microgrooved implants. In contrast, LM did show a significantly lower number of inflammatory cells and a significantly higher number of blood vessels in the capsules surrounding the microgrooved implants. Differences between the 2.0, 5.0, and 10.0 μm grooved implants were not detected. Our results concerning the capsule thickness suggest that the depth of our grooves was not sufficient to facilitate mechanical interlocking, but the cause for the observed differences in inflammatory response and number of blood vessels remains unclear. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 539-547, 1997.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 60-67 
    ISSN: 0021-9304
    Keywords: heat treatment ; calcium phosphate ; coating ; sputter ; implant ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study evaluated the effect of rapid heating with infrared radiation on the physico-chemical and morphological properties of radio frequent (RF) magnetron-sputtered calcium phosphate (Ca-P) coatings. About 2.5 μm thick Ca-P coatings were deposited on titanium disks and cylinders. These specimens were left untreated or were heat treated by infrared radiation at 300, 400, 500, 600, and 700°C for 4, 7, 11, 17, and 24 s. Subsequently, the specimens were immersed in simulated body fluid (SBF) for 1 day, 1 week, and 5 weeks. X-ray diffraction measurements showed that heating at 500°C or higher resulted in an increase of coating crystallinity. In addition, FT-IR measurements revealed the appearance of OH peaks in the spectra of samples treated at 500-700°C. Electron probe microanalysis showed that after 5 weeks of immersion about 40-50% of the coatings heat treated at 500 and 600°C was maintained. The coatings heat treated at 700°C showed no dissolution at all. On the other hand, as-coated and 300°C treated films were dissolved within 1 day. Scanning electron microscopy of the samples showed that directly after heat treatment no apparent cracks were present in the coatings. On the basis of these findings, we conclude that rapid heating with infrared radiation around 600°C is the best heat treatment for RF magnetron-sputtered coatings. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 60-67, 1997.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0021-9304
    Keywords: surface topography ; plasma etching ; cellular orientation ; focal adhesion point ; in vitro ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: During this study, microtechnology and plasma etching were used to produce gratings 1.0 (TiD01), 2.0 (TiD02), 5.0 (TiD05), and 10.0 μm wide (TiD10) into commercially pure titanium wafers. After incubation of rat dermal fibroblast (RDFs) on these surfaces for 3 days, the cells were observed with scanning electron (SEM), transmission electron (TEM), and confocal laser scanning microscopy (CLSM). Results showed that the RDFs as a whole and their stress fibers oriented strictly parallel to the surface pattern on the TiD01 and TiD02 surfaces. On the TiD05 and TiD10 surfaces, this orientation was not observed. In addition, TEM and CLSM demonstrated that the focal adhesion points (FAP) were located mainly on the surface pattern ridges. TEM revealed that FAP were wrapped occasionally around the edges of the ridges. Only the RDFs on both the TiD05 and TiD10 surfaces protruded into the grooves and possessed FAP on the walls of the grooves. Attachment to the groove floor was observed only on the TiD10 textures. Comparison of these results with earlier observations on microtextured silicone rubber substrata suggests that material-specific properties do not influence the orientational effect of the surface texture on the observed RDF cellular behavior. The proliferation rate of the RDFs, however, seems to be much higher on titanium than on silicone rubber substrata. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 40, 425-433, 1998.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 39 (1998), S. 524-530 
    ISSN: 0021-9304
    Keywords: magnetron sputtering ; calcium phosphates ; hydroxyapatite ; carbonate apatite ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Radiofrequency magnetron sputter deposition was used to deposit Ca-P sputter coatings on titanium discs, and these coatings were implanted subcutaneously into the backs of rabbits. Half of the as-sputtered coatings were subjected to additional heat treatment for 2 h at 500°C. X-ray diffraction (XRD) demonstrated that annealing at 500°C changed the amorphous sputtered coating into an amorphous-crystalline apatite structure. Scanning electron microscopic (SEM) examination of the sputtered coatings showed excellent coverage of the substrate surface. Annealing of the 4-μm-thick coatings resulted in the appearence of small cracks. SEM demonstrated that until 4 weeks of implantation, all heat-treated coatings were present and all amorphous coatings were completely or mostly dissolved. Fourier transform infrared spectroscopy showed the formation of carbonate apatite (CO3-AP) on these specimens. Furthermore, XRD analysis showed that these CO3-AP precipitated coatings disappeared after 8 weeks of implantation. On the other hand, SEM inspection of these specimens revealed that the 4-μm heat-treated coating was still partially maintained and that small Ca-P crystals were present on the titanium substrate. On the basis of these results, we conclude that apparently 0.1 μm heat-treated Ca-P sputter coating is of sufficient thicknesses to stimulate carbonate apatite deposition under in vivo conditions. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 39, 524-530, 1998.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 42 (1998), S. 634-641 
    ISSN: 0021-9304
    Keywords: biocompatibility ; subcutaneous implant ; implant surface ; microgrooves ; in vivo ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We investigated the behavior of microgrooved implants in soft tissue using polystyrene implantable disks, either smooth or microgrooved (1-10 μm) on both sides. The implants were placed subcutaneously in a goat for 1, 4, or 12 weeks. Light and transmission electron microscopy showed that fibrous capsule formation around the implants was fairly uniform. After 1 week the implants were covered with a fibrous capsule about 80 μm thick. The collagen matrix was loose, and many inflammatory cells were present. After 4 weeks the matrix was more dense and contained many newly formed blood vessels. At the implant surface a layer of inflammatory cells about 10 μm thick had accumulated. Finally, after 12 weeks the matrix had densified. One cellular layer of inflammatory cells was present at the implant surface. We carried out histomorphometric measurements of capsule thickness, inflammatory layer thickness, and the number of blood vessels. Capsule thickness appeared not to decrease with time. Further, these measurements showed that there were no differences in tissue reaction between smooth and microgrooved implants. On the basis of our observations, we suggest that 1 μm deep and 1-10 μm wide microgrooves do not influence tissue response around polystyrene implants in soft tissue. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 42, 634-641, 1998.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 511-518 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To evaluate the effect of surface treatment and surface microtexture on cellular behavior, smooth and microtextured silicone substrata were produced. The microtextured substrata possessed parallel surface grooves with a width and spacing of 2.0 (SilD02), 5.0 (SilD05), and 10 μm (SilD10). The groove depth was approximately 0.5 μm. Subsequently, these substrata were either left untreated (NT) or treated by ultraviolet irradiation (UV), radiofrequency glow discharge treatment (RFGD), or both (UVRFGD). After characterization of the substrata, rat dermal fibroblasts (RDF) were cultured on the UV, RFGD, and UVRFGD treated surfaces for 1, 3, 5, and 7 days. Comparison between the NT and UV substrata revealed that UV treatment did not influence the contact angles and surface energies of surfaces with a similar surface topography. However, the contact angles of the RFGD and UVRFGD substrata were significantly smaller than those of the UV and NT substrata. The dimension of the surface microevents did not influence the wettability characteristics. Cell culture experiments revealed that RDF cell growth on UV-treated surfaces was lower than on the RFGD and UVRFGD substrata. SEM examination demonstrated that the parallel surface grooves on the SilD02 and SilD05 substrata were able to induce stronger cell orientation and alignment than the events on SilD10 surfaces. By combining all of our findings, the most important conclusion was that physicochemical parameters such as wettability and surface free energy influence cell growth but play no measurable role in the shape and orientation of cells on microtextured surfaces. © 1995 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Various studies already have shown that the occurrence of oral implant failure is higher in the maxilla than in the mandible. To learn whether Ca-P coatings can improve the success rate of oral implants in the maxilla, three different plasma-sprayed, Ca-P-coated, self-tapping Brånemark® implants were inserted in the trabecular bone of the maxilla. Before the insertion of the implants, the two first upper premolars of 16 goats were bilaterally extracted. Four months later, each animal received four types of implants: three different Ca-P-coated types and one uncoated. After an endosseous period of 6 months, the implants were provided with permucosal abutments. Four months later the animals were killed. At the end of the experiment, it appeared that 10 of the 16 installed noncoated implants had failed while of the 48 Ca-P-coated implants, only 6 had failed. All successful implants were retrieved and prepared for histomorphometrical evaluation of the bone and gingiva response. The Ca-P-coated implants showed a significantly greater percentage of bone in contact with the implant surface compared with the uncoated implants. The length of the epithelium was not significantly different for the coated compared to the uncoated implants, but the connective tissue was significantly thicker for the noncoated implants than for the Ca-P-coated implants. Also, measurements revealed that all coatings showed reduction in thickness. On the basis of these findings, we concluded that the application of Ca-P coatings (1) improves the bone-implant reaction, although all coatings reduced in thickness, and (2) is of benefit during the healing period in less mineralized trabecular bone. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...