Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 4324-4332 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The recurrent difficulties of rapidly localizing a small object in a large volume of highly scattering material such as brain and breast has been the "stumbling block'' of optical methods for tumor detection. Amplitude cancellation of in- and out-of-phase photon diffusion patterns, used in detection of small objects containing highly absorbing and fluorescing contrast agents provides real time, two- and three-dimensional localization of objects of mg size and picamole contents in models of human breast and brain tumors with positional accuracies of millimeters. A simple robust electronic circuit is described and tested to give a phase accuracy of ∼0.1°. An electro-optical scan rapidly detects small objects in a large volume that simulates the absorption/scattering characteristics of human head or breast. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Molecular and cellular biochemistry 174 (1997), S. 7-10 
    ISSN: 1573-4919
    Schlagwort(e): mitochondrial disorders ; oxygen utilization ; optic oximetry
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract The dynamics of oxygen delivery and utilization are examined in a variety of mitochondrial disorders during rest, exercise and post exercise. We used a non-invasive optical technique to measure the oxygen consumption in the exercising limb in normal subjects and 5 patients with cytochrome c oxidase deficiency. We also examined 6 patients with MELAS and MERRF syndrome. We measured near-infrared spectra of hemoglobin in the gastrocnemius muscle during treadmill exercise. Normal subjects demonstrated a sustained deoxygenation during exercise, indicating an efficient utilization of delivered oxygen. Patients with cytochrome c oxidase deficiency demonstrated consistent oxygenation during exercise indicating an under utilization of delivered oxygen. Patients with MELAS and MERRF syndrome showed similar under utilization of oxygen during exercise. Non-invasive tissue oximetry during exercise demonstrates specific abnormalities in a variety of mitochondrial disorders, indicating abnormal oxygen utilization, and will be a useful addition to the clinical investigation of such disorders. (Mol Cell Biochem 174: 7–10, 1997)
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Molecular and cellular biochemistry 184 (1998), S. 445-455 
    ISSN: 1573-4919
    Schlagwort(e): mitochondria ; transplantable tumors ; rat liver ; near-infrared spectroscopy ; light absorption ; light scattering
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract In this study, the detailed dependence of light scattering on tissue architecture and intracellular composition has been investigated. Firstly, we simulated the reduced scattering coefficient (μs′) of the rat liver using the Mie theory, the Rayleigh-Debye-Gans approximation and electron microscopy data. Then, the reduced scattering coefficient of isolated rat liver mitochondria, isolated hepatocytes and various rat tissues (i.e. perfused liver, brain, muscle, tumors) was measured at 780 nm by using time-resolved spectroscopy and a sample-substitution protocol. The comparison of the isolated mitochondria data with the isolated hepatocyte and whole liver measurements suggests that the mitochondrial compartment is the primary factor for light propagation in hepatic tissue, thus strengthening the relevance of the preliminary theoretical study. Nevertheless, the possibility that other intracellular components, such as peroxisomes and lysosomes, interfere with light propagation in rat liver is discussed. Finally, we demonstrate that light scattering in normal rat tissues and tumors is roughly proportional to the mitochondrial content, according to estimates of the mitochondrial protein content of the tissues.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Digestive diseases and sciences 40 (1995), S. 1045-1053 
    ISSN: 1573-2568
    Schlagwort(e): liver ; reperfusion ; free radicals ; hepatic injury ; transplantation ; ischemia
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract It has been proposed that xanthine oxidase-derived superoxide mediates reperfusion injury in the liver; however, there is a little direct evidence to support this hypothesis. In this paper we describe a model system to directly and noninvasively measure oxyradical formation and hepatic injury in isolated perfused rat liver. Using this sensitive chemiluminescent technique, we clearly demonstrate the theorized burst in oxygen radical production upon reperfusion of previously ischemic liver, without perturbing the system with chemical luminescence enhancers. This increase in chemiluminescence (CL) upon reperfusion was diminished by the free radical scavengers trolox and ascorbate, as well as N-2-mercaptoproprionyl-glycine (MPG), thereby confirming the oxyradical nature of this signal. Additionally, superoxide dismutase and the xanthine oxidase inhibitor allopurinol, but not catalase, attenuated the reperfusion effect, providing the most direct evidence so far that XOD derived superoxide anion is formed during liver reperfusion. Hepatic injury (AST release) did not appear to relate to increased CL, supporting the notion that the oxyradical flux may serve as a signal for other events leading to tissue injury. Further studies using this sensitive chemiluminescent technique should aid in delineating the detailed mechanism(s) of reperfusion injury.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Journal of clinical monitoring and computing 11 (1995), S. 109-117 
    ISSN: 1573-2614
    Schlagwort(e): Oximetry ; near-infrared ; spectroscopy ; infant ; pediatric ; optical path length
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Informatik , Medizin
    Notizen: Abstract Background. Near-infrared spectroscopy (NIRS) is an emerging technique for noninvasive, bedside monitoring of cerebral oxygenation and blood flow. Traditionally, it has relied on the Beer's Law relationship in which the concentration of light-absorbing oxygen-carrying pigments is proportional to their light absorbance, and inversely proportional to an optical path length (a measure of the distance traveled by photons passing through the tissue). In practice, NIRS has been based upon assumptions that mean transcranial optical path length, the average optical path length for a given patient, is constant among patients and independent of the wavelength of light used.Objective. The objective of our study was to measure mean optical transcranial path length in infants as a step in allowing quantitation of cerebral oxygenation.Methods. We measured mean transcranial optical path length in 34 infants, aged 1 day to 3 years, using amplitude-modulated phase-shift spectroscopy at 754 nm and 816 nm. Optical transcranial path lengths (mean±SEM) were 8.6±0.9 cm, 11.1±0.9 cm, and 11.3±0.9 cm at 754 nm, and 8.8±0.9 cm, 11.2±0.8 cm, and 11.1±0.9 cm at 816 nm, using emitter-detector separations of 1.8, 2.5, and 3.0 cm, respectively. Optical path length increased as emitter-detector separation, head circumference, or age increased. Variance in the ratio of mean optical path lengths at the two different wavelengths exceeded that accounted for by variation in repeated measures alone (p〈0.001), suggesting that optical path length is also not independent of wavelength.Conclusions. NIRS instrument emitter-detector geometry, subject age, head size, and wavelength used each influence optical path length. Quantitative NIRS measurements in clinical use may require concurrent measurement of both absorbance and optical path length at each wavelength, or use of newer measures that are not based upon Beer's Law assumptions.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 1573-9686
    Schlagwort(e): Near infrared (NIR) spectroscopy ; Localization ; Imaging ; Absorber ; Fluorescent absorber ; Time resolved spectroscopy (TRS) ; Tumor detection ; Fluorescent ; Scattering media ; Spectra
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: Abstract Frequency response analysis via pulse testing for engineering systems and near infrared (NIR) time resolved spectroscopy (TRS) for biological system characterization involve identical principles: the system of interest is disturbed by an input pulse and the output response is observed. Since a sharp pulse, such as the Dirac delta function, contains the information of multimodulation frequencies (theoretically from 0 to ∞ in frequency) a narrow pulse TRS input can produce a wide range frequency response for identifying any system of interest. Currently used NIR-TRS spectral analyses either fit the spectra with a known theoretical solution or use photon mean time-of-flight. Transforming the system time domain representation to the frequency domain generates five system parameters that can be valuable for process identification utility: steady state gain, time constant, system order, and magnitude ratio and phase shift over a wide frequency range. Optical contrast agents or fluorescent agents can be used to enhance the capability of optical instruments in detecting biological heterogeneities. In this article, magnitude ratio, phase shift, and other system parameters derived from the transfer function of systems with both a fluorescent absorber and a regular absorber are correlated with the position of the absorber. This technique is important in that ultimately it can be used to enhance optical medical imaging. © 1998 Biomedical Engineering Society. PAC98: 8764Je, 0757Ty
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...