Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 92 (1990), S. 6408-6419 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The rotational spectra of H2S⋅CO2 and two deuterated forms have been observed using a pulsed-beam Fourier-transform microwave spectrometer. For each of the three complexes we assign a-type and c-type transitions which are split into a "weak'' and a "strong'' intensity component. The analysis based on that previously used for the (H2O)2 complex and modified for application to H2S⋅CO2, allowed us to assign internal rotation, inversion tunneling states of the H2S and CO2 units in the complex. The following rotational constants were determined for the ground tunneling state of each species: for H2S⋅CO2, A=11 048.0(26) MHz, B=2147.786(4) MHz, and C=1806.468(4) MHz; for HDS⋅CO2, A=10 769(35) MHz, B=2107.26(24) MHz, and C=1775.83(24) MHz; and for D2S⋅CO2, A=10 356.2(28) MHz, B=2065.376(8) MHz, and C=1746.122(8) MHz. The electric dipole moments were determined for the H2S⋅CO2 and D2S⋅CO2 species, resulting in the values μa=0.410(14) D and μc=0.822(10) D for the H2S⋅CO2 species. The structure of the complex has the CO2 and the S atom of H2S in a T-shaped configuration. The H2S plane is nearly orthogonal to the CO2–S plane with an angle of about 92° and the H2S⋅CO2 center-of-mass separation Rc.m. is 3.498(3) A(ring).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 3694-3699 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We present hardware and software details of the pulsed molecular beam microwave Fourier transform (MB-MWFT) spectrometer used in the Kiel microwave group. We emphasize an automatic scanning facility which greatly increases the efficiency of MB-MWFT spectroscopy for the measurement of unassigned spectra.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 102 (1995), S. 8693-8703 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Expressions are derived for the nuclear quadrupole splittings in the E3 and E4 (para–para) states of (NH3)2 and it is shown that these can be matched with the standard expressions for rigid rotors with two identical quadrupolar nuclei. The matching is exact only when the off-diagonal Coriolis coupling is neglected. However, the selection rules for rotational transitions are just opposite to those for the rigid rotor. Hyperfine splittings are measured for the J=2←1 transitions in the E3 and E4 states with ||K||=1; the quadrupole coupling constants χaa=0.1509(83) MHz and χbb−χcc=2.8365(83) MHz are extracted from these measurements by the use of the above mentioned correspondence with the rigid rotor expressions. The corresponding results are also calculated, with and without the Coriolis coupling, from the six-dimensional vibration–rotation–tunneling (VRT) wave functions of (NH3)2, which were previously obtained by Olthof et al. [E.H.T. Olthof, A. van der Avoird, and P.E.S. Wormer, J. Chem. Phys. 101, 8430 (1994)]. From the comparison of χaa with the measured value it follows that the semiempirical potential and the resulting VRT states of Olthof et al. are very accurate along the interchange (cursive-thetaA,cursive-thetaB) coordinate. From χbb−χcc it follows that this potential is probably too soft in the dihedral angle γ¯=γA−γB, which causes the torsional amplitude to be larger than derived from the experiment. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 112 (1990), S. 8193-8195 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1238
    Keywords: Key words Work of breathing ; Pressure ; time product ; Breathing pattern ; Continuous positive airway pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To analyze work of breathing (WOB) imposed by the respirators EVITA-2, EVITA-4 (Drägerwerk, Lübeck, Germany) and SV 300 (Siemens-Elema, Sweden) as well as inspiratory flow response and expiratory flow resistance during continuous positive airway pressure (CPAP). Design: Five study conditions on a lung model (CPAP at 0, 5, and 10 mbar, CPAP 5 mbar plus pressure support 2 mbar with both EVITA models, and CPAP 5 mbar with decreasing levels of flow and pressure trigger sensitivity with the SV 300) and three randomized study conditions in nine patients recovering from open heart surgery (condition A: EVITA-2, CPAP 5 mbar; condition B: SV 300, CPAP 5 mbar, flow trigger; condition C: SV 300, pressure trigger − 4 mbar). Setting: University hospital intensive care unit and laboratory of pulmonary physiology. Measurements and results: At each study condition we measured WOB, pressure–time product (PTP), WOB and PTP imposed (WOBimposed and PTPimposed), tidal volume, minute ventilation, respiratory rate, inspiratory trigger time, trigger pressure, trigger PTP, duration of inspiration, mean and peak inspiratory flow, and the delay from the onset of inspiration to peak inspiratory flow. Since the SV 300 automatically generates an additional pressure support of 2 cm H2O PTP, WOB, WOBimposed, and PTPimposed were higher with the EVITA-2 and EVITA-4 regardless of the trigger sensitivity set on the SV 300. The difference was neutralized with both types of EVITA ventilator by adding 2 mbar of pressure support during CPAP in order to achieve comparable conditions. Inspiratory flow response was faster with both EVITA models, expiratory flow resistance was higher with the SV 300. Decrements of trigger sensitivity with the SV 300 accelerated the flow response. Conclusions: Under similar conditions, no difference in WOBimposed was observed, although inspiratory flow response and expiratory flow resistance differed substantially between the three ventilators tested. Trigger sensitivity plays a minor role in determining PTP and WOB but has major influence on flow.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 25 (1999), S. 240-240 
    ISSN: 1432-1238
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-2153
    Keywords: Key words:Shock tube experiments, Formation of molecules, Microwave absorption technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics , Technology
    Notes: Abstract. The paper describes experimental investigations in a shock tube concerning the formation of new molecules using He as a driver gas and a mixture of Kr, CH $_4$ and NH $_3$ as driven gas, where Kr serves as diluant. By microwave absorption technique it was possible to detect HCN, CH $_2$ O and CH $_3$ NH $_2$ as reaction products. Obviously, these molecules were formed in the plasma behind the shock wave. In addition, the “swan bands” of C $_2$ have been observed with optical methods.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 8 (1994), S. 366-370 
    ISSN: 1432-2218
    Keywords: Laparoscopy ; Abdominal gunshot wounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The role of laparoscopy in the selective management of gunshot wounds (GSW) of the abdomen was prospectively investigated in 38 patients. All the patients were hemodynamically stable and had equivocal evidence of intraabdominal penetration. Laparoscopy was performed in the operating room under anesthesia. The site of penetration was in the thoracoabdominal area in 13, epigastrium in 7, and lower quadrants in 18. Twenty-three (60.5%) had nonpenetration on laparoscopy and a laparotomy was avoided. The remaining patients had injuries to the liver (4 patients), spleen (two patients), diaphragm (3 patients), hemoperitoneum or retroperitoneal hematoma (6 patients), and hollow viscus injuries (5 patients). Laparoscopy was also helpful in determining the need for laparotomy vs thoracotomy in lower chest wounds. The negative laparoscopy group (no penetration) had a significantly lower hospital stay compared to hemodynamically stable patients who had negative laparotomy without laparoscopy for nonpenetrating GSW. There were no complications related to laparoscopy. Laparoscopy is a useful modality in the evaluation of hemodynamically stable patients with abdominal missile wounds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 349 (1994), S. 272-276 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A pulsed molecular beam Fourier transform microwave spectrometer especially designed for the quantitative analysis of polar pollutants in air is presented. This very fast method has a sensitivity in the ppm range and can be applied to a wide variety of substances. Details of the apparatus and the results of some performance tests are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...