Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • thermal diffusivity  (2)
  • angiotensin converting enzyme inhibitor  (1)
Material
Years
Year
  • 1
    ISSN: 1432-1041
    Keywords: Enalapril ; Hypertension ; angiotensin converting enzyme inhibitor ; glucose tolerance ; insulin sensitivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The effect of enalapril, an angiotensin converting enzyme inhibitor, on glucose tolerance and serum insulin response to a glucose load has been evaluated in 8 non-obese patients (3 women and 5 men) with untreated essential hypertension (WHO Stage I or II) and without insulin resistance. Following a 2-month run-in control period, each patient received oral enalapril 10 mg once daily for 6 months, and an intravenous glucose tolerance test (IVGTT) was performed at the end of the run-in control and active treatment periods. Treatment with enalapril significantly lowered both the systolic and diastolic blood pressures. The response of plasma glucose to the IVGTT, glucose disappearance rate (k-value) and area under the serum insulin concentration time curve were comparable between the two phases. The results suggest that long-term treatment with enalapril has no effect on glucose tolerance in non-obese, non-insulin-resistant patients with mild-to-moderate essential hypertension.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 15 (1994), S. 317-341 
    ISSN: 1572-9567
    Keywords: high temperature ; laser pulse method ; thermal diffusivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A high-temperature laser-pulse apparatus for the measurement of thermal diffusivity in the temperature range from 1500 to 2500 K has been designed. constructed, and tested at the National Institute of Standards and Technology. A curve-fitting method is introduced by which the entire experimental temperature history curve is fitted with the theoretical curve under the boundary condition of radiative heat losses. The new apparatus and the curve-fitting method permit thermal diffusivity measurements with an uncertainty of not more than 3%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 15 (1994), S. 343-364 
    ISSN: 1572-9567
    Keywords: graphite ; high temperatures ; laser-pulse method ; reference material ; thermal diffusivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The thermal diffusivity of POCO AXM-5Q1 graphite was measured in the temperature range 1500 to 2500 K utilizing the laser-pulse technique. The uncertainty of the values is estimated to be no more than 3%. The measured values are compared with the results of other investigators.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...