Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (1)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 21 (1988), S. 330-339 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A new multipurpose X-ray small-angle scattering camera system consisting of a rotating-anode X-ray generator, a double-focusing collimator and a two-dimensional position-sensitive detector has been developed at the High-Intensity X-ray Laboratory of Kyoto University. The overall camera length is 6 m, and the sample-to-detector distance can be varied in 0.5 m increments up to 3 m to cover scattering angles ranging from 0.001 to 0.18 rad. The collimator consists of a pair of crossed-plane total-reflection mirrors of 40 cm in length. The mirrors, which are mechanically bent to form cylindrical surfaces, provide point collimation free of collimation error. General-purpose sample holders equipped with a programmable temperature controller are provided for both transmission and scattering measurements; the temperature is maintained within ± 0.1 K in the range of 223–573 K. A cryostat for measurements down to 20 K, a dynamic sample deformation apparatus, and a temperature-jump equipment are also available. The multi-wire delay-line position-sensitive proportional counter has an active area of 128 × 128 mm with a spatial resolution of 0.5 × 1.0 mm. The data acquisition is controlled by a real-time front-end processor through a CAMAC interface. The data are recorded in a dual-port histogramming memory of 32 bit × 1 Mwords, which enables direct access to the data from the main computer for real-time monitoring and analysis. The performance of the camera is demonstrated with some selected examples: diffraction patterns from carp lateral line nerve myelin and chicken-tendon collagen fibrils, a Guinier plot of the scattering from polystyrene in dilute solution, and time-resolved measurements of polypropylene during the annealing process.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...