Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (2)
  • 1980-1984  (2)
Material
  • Electronic Resource  (2)
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical and experimental pharmacology and physiology 11 (1984), S. 0 
    ISSN: 1440-1681
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: 1. The time of onset and dose threshold for ACTH induced hypertension was examined in conscious sheep.2. ACTH 1 μg/kg per day significantly raised blood pressure. The maximum rise occurred at 2 μg/kg per day.3. The rise in pressure was significant after 8 h of ACTH infusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 99-109 
    ISSN: 1573-4862
    Keywords: thermography ; infrared scanning ; calibration ; inverse problems ; cavity detection ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An approach for treating nondestructive testing as the solution of inverse problems in mathematical physics has been used for the detection of cavities. The approach is developed based on the use of an additional boundary condition of scanned temperature on the surface to solve for the cavity geometry. For the present study, the condition at the cavity side is taken to be that of a specified temperature, and the experiment is carried out to meet this condition. Two specimens are tested in this paper, a plane slab and a rectangular prism. In both bodies the cavity is rectangular in shape. For the testing of the plane slab, the method is able to detect the cavity wall with high accuracy, whereas the cavity depth error is larger (6%). The detection of the cavity position in the rectangular prism has an error ranging from −9.7 to 7.7%. Errors in the experiment are attributed to the uncertainties in the measurements of temperature and the Biot number. The former is read off from the analog data output of the infrared scanner. The latter is not measured separately, but is computed from the scanned data and thus becomes a portion of the total nondestructive testing output. A final note is also made in this paper to relate how the presented method can be used in actual practice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...