Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 19 (1994), S. 6-7 
    ISSN: 1432-0509
    Keywords: Esophagus, stricture ; Esophagitis, drug-induced
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A 37-year-old man experienced acute odynophagia after ingesting a single tablet of Motrin (ibuprofen, 800 mg). Because the pill was swallowed without water, a transient delay in its passage through the esophagus resulted in localized mucosal inflammation and a druginduced stricture.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 19 (1994), S. 295-297 
    ISSN: 1432-0509
    Keywords: Stomach ; inflammation ; Antral deformity ; drug-induced ; Gastropathy ; NSAID complication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We have occasionally encountered patients on nonsteroidal antiinflammatory drugs (NSAIDs) in whom double contrast barium studies revealed persistent flattening and stiffening of the distal greater curvature of the stomach. We therefore performed a study to determine the frequency of this finding in patients with NSAID-related gastropathy. Twenty-one cases of erosive gastritis, gastric ulcers, and/or gastric scarring associated with a known history of NSAID use were reviewed by two radiologists who made a joint decision regarding the presence or absence of greater curvature antral flattening. This finding was seen radiographically in five of the 21 patients (24%). Four of the five patients with antral flattening had associated erosions or ulcers in the gastric antrum. The remaining patient had antral flattening as an isolated finding. Our experience suggests that flattening of the greater curvature of the distal antrum, particularly if associated with erosive gastritis or gastric ulcers, is a useful radiologic sign of NSAID-related gastropathy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Biological cybernetics 65 (1991), S. 459-467 
    ISSN: 1432-0770
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Computer Science , Physics
    Notes: Abstract Simulated neural impulse trains were generated by a digital realization of the integrate-and-fire model. The variability in these impulse trains had as its origin a random noise of specified distribution. Three different distributions were used: the normal (Gaussian) distribution (no skew, normokurtic), a first-order gamma distribution (positive skew, leptokurtic), and a uniform distribution (no skew, platykurtic). Despite these differences in the distribution of the variability, the distributions of the intervals between impulses were nearly indistinguishable. These inter-impulse distributions were better fit with a hyperbolic gamma distribution than a hyperbolic normal distribution, although one might expect a better approximation for normally distributed inverse intervals. Consideration of why the inter-impulse distribution is independent of the distribution of the causative noise suggests two putative interval distributions that do not depend on the assumed noise distribution: the log normal distribution, which is predicated on the assumption that long intervals occur with the joint probability of small input values, and the random walk equation, which is the diffusion equation applied to a random walk model of the impulse generating process. Either of these equations provides a more satisfactory fit to the simulated impulse trains than the hyperbolic normal or hyperbolic gamma distributions. These equations also provide better fits to impulse trains derived from the maintained discharges of ganglion cells in the retinae of cats or goldfish. It is noted that both equations are free from the constraint that the coefficient of variation (CV) have a maximum of unity. The concluding discussion argues against the random walk equation because it embodies a constraint that is not valid, and because it implies specific parameters that may be spurious.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Biological cybernetics 65 (1991), S. 469-477 
    ISSN: 1432-0770
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Computer Science , Physics
    Notes: Abstract Previous studies of the variability of firing of retinal ganglion cells have led to apparently contradictory conclusions. To a first approximation, maintained discharges derive their variability from a noise source that is linearly added to the signal setting the mean firing rate. On the other hand, the variability of responses to abrupt changes in lighting seems to result from a nonlinear interaction between signal and noise. In both the cat and the goldfish retinae, the variance of rate is a fractional power function of the mean response amplitude (impulses/s). The exponent of that power function depends on the duration of the period in which the response is sampled after each transition in luminance; longer durations have a larger exponent. These results are difficult to explain with any simple model. The variability of the maintained discharges also deviates from the predictions of simple additivity. We propose a model for the variability of responses to abrupt changes in lighting that incorporates variability of the form observed for maintained discharges. The parameters of our model that provide the best fits to the variability of responses also provide a reasonable fit to the variability of maintained discharges. Thus, a single explanation can account for the variability of maintained discharges and responses of ganglion cells.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 36 (1979), S. 275-283 
    ISSN: 1432-1106
    Keywords: Spatial orientation ; Visual direction ; Motor control ; Tonic vibration reflex ; Myesthetic illusions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Some aspects of the manner in which the central nervous system uses sensory information for the guidance of eye and arm movements were investigated. When subjects experience apparent motion of their restrained forearm, induced by vibration of their biceps muscle in the dark, they are able to pursue with their eyes at least part of this “motion” and to point with their nonvibrated limb to the apparent location of the vibrated arm. The presence of a small target light on the vibrated hand limits the extent of illusory change in limb position and results in illusory motion of the target light in the same direction as the arm motion. When asked to indicate the spatial position of the light or hand, subjects still point with their nonvibrated arm to the apparent locations. Although visual pursuit of the illusory motion of the forearm can still be elicited in the presence of the target light on the hand, the subjects' eyes remain steadily fixating the stationary target light when they are instructed to track its illusory motion. These findings demonstrate that sensory and motor factors affecting the perception of visual direction and the guidance of arm and eye movements can be differentially employed at several levels of central nervous control.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Psychology 44 (1993), S. 525-558 
    ISSN: 0066-4308
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Psychology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Environment and Resources 17 (1992), S. 405-435 
    ISSN: 1056-3466
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 2338-2342 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high-throughput von Hámos-type Bragg crystal spectrometer is described that is operated with the Livermore electron beam ion trap. The spectrometer is employed to measure high-resolution x-ray spectra from highly charged heliumlike and neonlike ions. Data from heliumlike Ti20+ and Fe24+ and from neonlike Au69+ are presented to demonstrate the utility of the new instrument.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An electron-beam ion trap (EBIT) has just been completed in the Clarendon Laboratory, Oxford. The design is similar to the devices installed at the Lawrence Livermore National Laboratory. It is intended that the Oxford EBIT will be used for x-ray and UV spectroscopy of hydrogenic and helium-like ions, laser resonance spectroscopy of hydrogenic ions and measurements of dielectronic recombination cross sections, in order to test current understanding of simple highly charged ions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Neuroscience 13 (1990), S. 195-225 
    ISSN: 0147-006X
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...