Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1434-6052
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We present results on charged current inclusive neutrino and antineutrino scattering in the neutrino energy range 30–200 GeV. The results include a) total cross-sections; b)y distributions; c) structure functions; and d) scaling violations observed in the structure functions. The results, as well as their comparison with the results of electron and muon inclusive scattering, are in agreement with the expectations of the quark parton model and QCD.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 345 (1977), S. 607-608 
    ISSN: 1435-2451
    Keywords: Osteosynthesis ; radiation exposure ; Osteosynthesen ; Strahlenbelastung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: ZusammenfaBung Bei 30 von verschiedenen Operateuren durchgeführten groBen Osteosynthesen wurde die Strahlenbelastung (Ganzkörper- und Teilkörperbestrahlung) mittels Fotoluminiscenzdosimetern gemeBen. Die ermittelten Belastungswerte für das Personal sind so geringfügig, daB sie vernachläBigt werden können. Ebenfalls die Strahlenbelastung des Operateurs bezüglich der Gonaden. Kritische Werte dagegen bei der Strahlenbelastung der Augen und Hände werden bei längeren Einschaltzeiten bei häufigen Osteosynthesen erreicht. Aus diesem Grunde muB ausdrücklich vor zu häufiger Anwendung und Einschaltung auch des Bildverstärkers gewarnt werden.
    Notes: Summary During major osteosynthesis operations performed by 30 different surgeons, the average amount of radiation exposure (whole and partial body) was measured using a photoluminescence dosimeter. The values determined for whole and partial body exposure, as well as for the gonads, were so slight that they could be ignored. However, critical values of radiation exposure of eyes and hands were reached due to prolonged exposure during frequent osteosyntheses. For this reason, frequent use and switching on of the video amplifier should be guarded against.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...