Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary. Ovarian arterial velocimetry, using real-time two-dimensional and pulsed Doppler ultrasound, was performed on 36 occasions in nine healthy women with regular menstrual cycles. The change in ovarian arterial compliance was based on the calculation of pulsatility index (PI). In the active ovary carrying a dominant follicle or corpus luteum, the PI in the early follicular phase (mean 6.97, SD 2.01) was significantly higher than that in the late follicular phase (mean 2.36, SD 0.31) (P〈0.001), and the PI in the early luteal phase (mean 0.68, SD 0.09) was significantly lower than that in the late follicular phase (P〈0.001). The PI in the late luteal phase (mean 0.93, SD 0.16) was significantly higher than that in the early luteal phase (P〈0.01). In the inactive ovary, no cyclical changes were seen in the values of PI. There was a significant difference between the values of PI in the active ovary and the inactive ovary in the late follicular, the early and the late luteal phases [2-36 (SD 0-31)] vs [6-29 (SD 1-02)], [0-68 (SD 0.09)] vs [6.18 (SD 1.33)], [0.93 (SD 0.16) vs [6-57 (SD 1.72)] (P〈0.001), respectively. Use of non-invasive Doppler ultrasound to study physiology of ovarian haemodynamics during the menstrual cycle is of great clinical relevance and paves the way for further investigations on sterility.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 5 (1972), S. 663-674 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 3 (1970), S. 472-473 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 3 (1970), S. 473-474 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 65 (1989), S. 2238-2242 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: Solid-phase-epitaxial (SPE) regrowth from selectively As+-implanted amorphous Si is analyzed by cross-sectional transmission electron microscopy. SPE regrowth in the (100) wafers proceeds into both vertical and lateral directions simultaneously. For (111) samples, SPE regrowth in the diagonal direction, i.e., 〈100〉 direction near the mask edge, is dominant. In addition to the end of range defects and projected range defects, in the SPE process, defects of a third type are generated just beneath the implantation mask edge. Differences in mask material which control the applied stress at the mask edge have little influence on edge defect generation. Substrate orientation and mask pattern direction play important roles in the edge defect formation mechanism.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 66 (1989), S. 1876-1878 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: B+-implanted Si layers preamorphized with 100-keV Ge+ implantation have been evaluated using Rutherford backscattering spectrometry and the van der Pauw technique. We suggest that the lower structural recovery, 98% of Si occupies substitutional sites, arises from the difference in tetrahedral covalent radii among Si, Ge, and B atoms. Electrical properties of dual Ge+/B+-implanted layers are discussed by a two-carrier model consisting of both electron and hole. The conversion temperature from the p- to the n-type varies from ∼15 to ∼ 125 °C with increasing electrical activation of the boron acceptor. The activation saturates at annealing temperatures above 800 °C. This restriction is due to the presence of the level and/or the defect induced in the preamorphization process.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 2566-2570 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The characteristics of microchannel plates (MCPs) for x-ray detection have been investigated with continuous x-ray energy variation using synchrotron radiation in the XUV and soft x-ray region (from 60 to 600 eV). The current response data have shown x-ray absorption fine structure (EXAFS or XANES) near the oxygen K absorption edge as well as a jump structure near the silicon L edge; these structures are explained by the surface composition of channel walls (SiO2). The data show that the surface layer of a microchannel is essential for x-ray detection by MCPs in this energy range. The precise current response curve has been completed for the wide x-ray energy range from 0.06 to 82 keV combined with the previously reported data [Kondoh et al., Rev. Sci. Instrum. 59, 252 (1988); Cho et al., ibid. 59, 2453 (1988); Yamaguchi et al., ibid. 60, 368, 2307 (1989)].
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Using undulator radiation from 2 to 8 keV, quantum efficiencies [QE(E)] of gold photocathodes, microchannel plates (MCP), and silicon surface barrier (SSB) detectors have been investigated. For the gold photocathodes, the detailed structure of QE(E) near the M absorption edges has been presented. Also, the secondary electron conversion efficiency of gold has been calculated using the mass absorption coefficient given by a relativistic Hartree–Slater model and by the semiempirical values of Henke et al., respectively. Extended x-ray absorption fine structure (EXAFS) has been observed in the secondary electron current of the gold photocathode as well as in the detection current responses of an MCP and of an SSB detector. Furthermore, the new findings adding to our recent paper1 have been summarized as follows: (i) EXAFS above the Si-K edge in the MCP response depends on photon incident angles, and (ii) a little upshift of the starting point energy of EXAFS in the MCP response is observed. These detailed characteristics and their interpretation are described in the following: (i) The current responses of the MCP are obtained as a function of the incident x-ray energy for θ=13° (the bias angle of the MCP), and 40° by using a gold-monitor current. Here, θ denotes the incident angle of the photons to the channel. The data for θ=40° show a smaller jump near the Si-K edge as compared with the data for θ=13°.This is explained as follows: The incident photons for θ=13° are irradiated to and absorbed in the MCP ingredient of SiO2, while photons for θ=40° are incident to the electrode region. (The depth of the electrode coating is more than 10 μm from the MCP surface, while the photons are absorbed at less than 8 μm from the surface for θ=40°.) Thus, the data for θ=40° strongly reflect the characteristics of the electrode, but not of SiO2. The data for several values of θ consistently indicate that the height of this jump becomes smaller with increasing θ. (ii) The observed upshift of the starting point energy of EXAFS in the MCP response presents a contrast to EXAFS in the SSB detector response, in which upshift is not observed. This upshift is ascribed to the molecular structure of SiO2 (the chemical shift); that is, some valence electrons are removed from the Si atoms due to the oxidation (i.e., SiO2). Thus, the screening effects of the valence electrons on the core electron-nucleus attraction are reduced. This results in the shift of binding energy towards the higher-energy side. On the other hand, EXAFS in the SSB detector response reflects the characteristics of Si.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 368-371 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The characteristics of microchannel plates (MCPs) for detection of x rays have been investigated using synchrotron radiation in the energy range from 1.8 to 8 keV. The current response curve of MCPs is measured with approximately continuous x-ray energy variation, which is added to the previous data [T. Kondoh et al., Rev. Sci. Instrum. 59, 252 (1988)]. It is confirmed that there is a minimum in the current response at the x-ray energy of about 4 keV. The precise current response curve has been completed for the wide x-ray energy range from 0.6 to 20 keV. A transition in the incident angle dependence of current response is found from the feature based on single cylindrical photocathode model for soft x rays to that based on multiple channel activation due to the penetration of x rays through channel walls for hard x rays. In the current response of MCPs the structure similar to that in EXAFS is observed near the Si K edge.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The quantum efficiency of gold photocathodes has been investigated by using synchrotron radiation from 2–8 keV; in particular its detailed structure near the M absorption edge region is obtained. The secondary electron conversion efficiency of gold has been calculated by using the mass absorption coefficient given by a relativistic Hartree-Slater model and by the semiempirical values of Henke et al., respectively. These data are compared with the published data at some discrete energies, and we add several new data points, especially for the gold M edge region (2–4 keV). X-ray absorption fine structure (EXAFS) has been observed in the secondary electron current of the gold photocathode as well as in the detection current responses of a microchannel plate and a silicon surface barrier detector.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...