Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (8)
  • 1960-1964  (6)
Material
Years
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 52 (1980), S. 1292-1296 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 203 (1964), S. 20-33 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A simple titrimetric ultramicro method allows the determination of carbon in not easily volatile organic compounds using sample weights of 10–30 μg. Comparable quantities of S, P, N, Cl, Br, I do not interfere. The standard deviation of the method is ± 0,08 μg C. Sulphur-free substances are burnt at 1000°C in pure oxygen, sulphur containing substances at 550°C in presence of an Ag-Mn-PbCrO4 catalyst. The combustion is carried out with an electrically heated Pt-spiral in a slow stream of oxygen. The carbon dioxide is absorbed in 0.01 M Ba(OH)2 solution. Complete absorbance is attained by using a special stirrer. The excess of Ba2+ ions is photometrically back-titrated with a 0.01 M EDTA solution and phthalein purple as indicator.
    Notes: Zusammenfassung Eine einfache titrimetrische Ultramikromethode gestattet die Bestimmung des Kohlenstoffs schwerflüchtiger organischer Substanzen (10–30 μg) nach Lösungsteilung. Schwefel, Phosphor, Stickstoff, Chlor, Brom und Jod stören nicht, wenn sie in der gleichen Größenordnung wie der Kohlenstoff vorliegen. Die Standardabweichung der Methode beträgt ±0,08 μg Kohlenstoff. Schwefelhaltige Substanzen werden bei 550°C mit einem Ag-Mn-Bleichromatkatalysator, alle anderen Verbindungsklassen in einem reinen Sauerstoffstrom bei über 1000°C verbrannt. Gezündet wird mit einer elektrisch heizbaren Platinspirale. Zur Bestimmung wird das Kohlendioxid in 0,01 m Bariumhydroxidlösung unter Zuhilfenahme eines hochtourigen Glockenrührers absorbiert und der Überschuß der Bariumionen in 60% dioxanhaltiger Lösung gegen Phthaleinpurpur komplexometrisch zurücktitriert. Die Endpunktsanzeige wurde photometrisch vorgenommen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 205 (1964), S. 40-50 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary For the determination of nitrogen in ultramicro amounts of nonvolatile organic compounds 5–20 μg of the substance are measured by taking an aliquot of a solution of known strength. This aliquot is filled into a small quartz tube, the solvent is evaporated by blowing with filtered air, and the remaining substance is pyrolyzed in streaming hydrogen at 〉1000°C. Thereafter the nitrogen is converted to ammonia by an iron catalyst at 400°C, and the ammonia is titrated iodometrically with biamperometrical indication. The standard deviation of the method is ±0,016 μg N. Quantities of S, F, Cl, Br and J comparable to the amount of nitrogen do not interfere.
    Notes: Zusammenfassung Zur Ultramikrobestimmung von Stickstoff in schwerflüchtigen organischen Verbindungen werden 5–20 μg Substanz durch Lösungsteilung abgemessen und nach der Entfernung des Lösungsmittels bei 〉1000°C im Wasserstoffstrom pyrolysiert. Der Stickstoff wird anschließend durch einen Eisenkontakt bei 400°C quantitativ in Ammoniak überführt, das jodometrisch mit biamperometrischer Endpunktsanzeige titriert wird. Die Standardabweichung des Verfahrens beträgt ±0,016 μg N. Die Bestimmung wird durch Schwefel und Halogene nicht gestört.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 205 (1964), S. 29-40 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary For the determination of chlorine in ultramicro amounts of nonvolatile organic compounds 1–10μg of the substance are measured by taking an aliquot of a solution of known strength. This aliquot is filled into a small quartz tube, the solvent is evaporated by blowing with a stream of filtered air, and the remaining substance is burnt in a stream of oxygen at 1000–1100° C. The HCl formed is absorbed in glacial acetic acid and titrated by help of differential electrolytic potentiometry. The relative standard deviation is ±1,5%. Quantities of N, P, S and F comparable to the amount of chlorine do not interfere. For the determination of chlorine in substances containing bromine and iodine silver electrodes are to be used.
    Notes: Zusammenfassung Zur Ultramikrobestimmung schwerfüchtiger organischer Stoffe werden 1–10 μg Substanz durch Lösungsteilung abgemessen und nach Entfernung des Lösungsmittels im Sauerstoffstrom bei 1000–1100°C verbrannt. Der gebildete Chlorwasserstoff wird in einer Vorlage in Eisessig absorbiert und argentometrisch titriert. Die Endpunktsanzeige erfolgt durch differentielle elektrolytische Potentiometrie mit AgCl-Elektroden. Die relative Standardabweichung beträgt 1,5%. Stickstoff-, P-, S- und F-Mengen in der Größenordnung des Chlorgehaltes verursachen keine Störungen. Bei brom- bzw. jodhaltigen Verbindungen müssen reine Silberelektroden verwendet werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 317 (1984), S. 1-4 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung PIXE ist aus dem Stadium der Methodenentwicklung in das Stadium der praktischen Anwendung als elementanalytische Methode mit hoher Nachweisstärke hineingewachsen. Bestimmungen bis in den ng- und pg-Bereich, insbesondere bei geringen Probenmengen, sind mit dieser spektroskopischen Methode möglich. PIXE weist spezifische Vorteile für Problemlösungen bei der Routineanalytik von (a) Luftstaubproben und (b) Spurenelementverteilungen in Festkörpern und biologischen Präparaten auf. Die technischen Möglichkeiten für den analytischen Einsatz einiger bestehender PIXE-Einrichtungen sowie deren wichtigste Arbeitsgebiete und ihre analytischen Kapazitäten sind zusammengestellt.
    Notes: Summary PIXE has advanced from the stage of methods development to the stage of its practical application as an analytical method offering high power of detection. Elements can be detected down to the level of the ng- and pg-traces, particularly from small mass samples. Specific advantages of this method are encountered when applied to the solution of problems in routine analysis of (a) particulate aerosols and (b) local distributions of trace elements in solid materials and biological tissue sections. A compilation is made of some of the existing PIXE facilities, their technical capabilities, their main fields of application and their analytical capacities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 317 (1984), S. 620-621 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 190 (1962), S. 161-185 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Durch Kombination einer Anzahl von Ausschüttelverfahren werden 35 Kationen voneinander getrennt und durch Farbreaktionen nachgewiesen. Dabei liegen die Grenzkonzentrationen für die einzelnen Nachweise zwischen 0,2 und 3 μg/ml Lösung und die Grenzverhältnisse günstiger als 1∶1000. Der Trennungsgang ist einfach und schnell in der Durchführung und besonders für mikroanalytische und spurenanalytische Aufgaben geeignet. Die gegebenen Arbeitsvorschriften wurden an Hand umfangreicher Untersuchungen erprobt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 194 (1963), S. 20-44 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Zur Bestimmung kleinster Mengen F-, S- und P-haltiger organischer Stoffe wurden Aufschluß- und Bestimmungsverfahren für die drei Elemente entwickelt, die zur Durchführung von Elementaranalysen mit Substanzmengen unter 10 μg geeignet sind. Die Aufschlüsse werden durch Verbrennung der Substanz in der Sauerstoffflasche und durch Oxydation mit Salpetersäure und Perchlorsäure im offenen Gefäß durchgeführt. Fluorid wird im Bereich von 0,5–2,5 μg oder darüber spektralphoto-metrisch nach der Zr-Eriochromcyaninmethode und bei Mengen im Bereich von 0,1–1 μg nach einem Ausbleichverfahren, das die Extrahierbarkeit von Zr-Morinat mit Methylisobutylketon ausnutzt, bestimmt. Kleinste Schwefelmengen werden nach Überführung in Sulfat zu Schwefelwasserstoff reduziert und mit einer Cd-Lösung titriert. Als Indicator dient in Tetrachlorkohlenstoff gelöstes Dithizon. Phosphormengen zwischen 0,05 und 1 μg P werden nach dem Zinzadze-Verfahren bestimmt, wobei der gebildete Molybdänblaukomplex mit Methylisobutylketon ausgeschüttelt und die organische Phase bei 780 nm photometriert wird.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 200 (1964), S. 20-37 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Three methods were developed for the determination of amounts 〈1 μg of iodine in not easily volatile organic substances. The argentometric titration in a two-phase system with diphenylthiocarbazone permitted the determination of 1 μg of I with a standard deviation of ±4 ng. The advantage of this method lies in its simple and rapid manipulation. Nearly the same sensitivity is obtained by a little more complicated iodometric titration with amperometric indication. 129,4 ng of iodide can be determined with a standard deviation of ±2,3 ng, when using 0,0001 n solutions, and 1,90 μg of I− with a standard deviation of 21 ng using 0,001 n solutions. A standard deviation of ±8 ng is obtained for the photometric determination of iodine by the crystal violet-iodine chloride method. These three procedures described above show that the combustion in the oxygen flask can be carried out even with amounts smaller than one microgram without any interference. Addition of picric acid to the paper holding the substance is recommended to increase the combustion temperature and to burn completely less easily combustible compounds. The absolute error resulting from this digestion method is less than 2 ng.
    Notes: Zusammenfassung Für die Bestimmung von Jodmengen 〈1 μg in schwerflüchtigen organischen Substanzen wurden 3 Verfahren entwickelt. Durch argentometrische Zweiphasentitration mit Dithizon als Indicator ließ sich 1 μg J mit einer Standardabweichung von ±4 ng bestimmen. Der Vorteil dieses Verfahrens liegt in seiner einfachen und schnellen Durchführung. Etwa die gleiche Empfindlichkeit weist die etwas umständlichere jodometrische Titration mit amperometrischer Endpunktsanzeige auf. Mit 0,0001 n Lösungen wurden 129,4 ng Jodid (Standardabweichung ±2,3 ng) und mit 0,001 n Lösungen 1,901 μg (Standardabweichung ±21 ng) bestimmt. Nicht ganz so genau ist die photometrische Jodbestimmung über das Kristallviolett-jodchlorid (Standardabweichung ±8 ng). Mit Hilfe dieser 3 Verfahren konnte gezeigt werden, daß die Verbrennung in der Sauerstoffflasche mittels Papierträger auch mit Substanzmengen kleiner als 1 μg störungsfrei verläuft. Für schlecht verbrennbare Substanzen wird ein Zusatz von Pikrinsäure zur Erhöhung der Verbrennungstemperatur empfohlen. Der absolute Fehler, der sich durch die Aufschlußmethode ergab, war kleiner als 2 ng.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...