Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1955-1959  (5)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 45 (1957), S. 784-795 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A study was made of the triple salts of the type: NaMe(II)(UO2)3(CH3COO)9· The triple salts of Me=Ca, Cd, Ma, Fe(II), Co, Ni, Cu were described. The salts of nickel and cobalt, which are most suitable for analytical purposes were used for the quantitative determination of sodium. The gravimetric determination using the nickel salt shows an error of 0.8%, that using the cobalt salt 0.5%. The salts were subjected to a complexometric titration. The errors are less than 1%. The effect of foreign ions, especially the alkali metals, and of other divalent metals was studied. This error likewise is below 1%.
    Abstract: Résumé Recherches sur les sels triples du type NaMe(II)(UO2)3(CH3COO)9 et description des sels dans lesquels Me=Ca, Cd, Mn, Fe(II), Co, Ni, Cu. Les sels de Ni et Co, les plus appropriés pour des applications analytiques, sont utilisés pour le dosage du sodium. Le dosage gravimétrique sous forme de sel de nickel comporte une erreur de 0,8% tandis que cette dernière n'est que de 0,5% pour le sel de cobalt. Les sels soumis à un titrage complexométrique ne donnent lieu qu'à des erreurs inférieures à 1%. L'influence des ions étrangers, celle des métaux alcalins en particulier et celle d'autres métaux bivalents, a été également étudiée; elle conduit à une erreur inférieure à 1 %.
    Notes: Zusammenfassung Es werden die Tripelsalze vom Typus NaMe(II) (UO2)3(CH3COO)9 untersucht. Die Tripelsalze mit Me=Ca, Cd, Mn, Fe(II), Co, Ni, Cu werden beschrieben. Die für analytische Zwecke am besten geeigneten Salze des Ni und Co werden zur quantitativen Natriumbestimmung herangezogen. Die gravimetrische Bestimmung als Nickelsalz zeigt einen Fehler von 0,8%, die des Kobalts einen Fehler von 0,5%. Die Salze werden einer komplexometrischen Titration zugeführt. Die Fehler liegen unter 1%. Der Einfluß von Fremdionen, besonders der Alkalimetalle und anderer zweiwertiger Metalle, wird untersucht. Dieser Fehler liegt ebenfalls unter 1%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 144 (1955), S. 113-115 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Mehrere einfache Monoazofarbstoffe erwiesen sich als empfindliche qualitative Magnesiumreagenzien. Die Reaktionen werden auf der Tüpfelplatte ausgeführt, die Anwesenheit kleiner Mengen Magnesium wird durch einen Farbumschlag der Lösung erkannt. Bei größeren Mengen Magnesium fällt ein durch Farbstoffadsorption gefärbter Magnesiumhydroxydniederschlag aus. Die Reaktionen werden durch die anderen Erdalkalien nicht gestört. Die kleinste nachweisbare Menge Magnesium ergab sich zu 0,1 μg, die höchste erreichbare Verdünnungsgrenze betrug 1∶1500000.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 144 (1955), S. 264-272 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Es wurden weitere Azofarbstoffe in bezug auf ihre Eignung zum Magnesiumnachweis untersucht. Man erreichte eine Identifizierungsgrenze von 0,1 μg Mg und eine Grenze der Verdünnung von 1 ∶ 1500000. Wahrscheinlich ist eine bestimmte Molekülstruktur für den Farbumschlag verantwortlich.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 147 (1955), S. 321-326 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Es wird ein neues, in der Empfindlichkeit dem Diphenylcarbazid ähnliches Reagens auf Chromat beschrieben. Die mit dem Colorimeter nach Dr. B. Lange erreichbare Empfindlichkeit beträgt 0,1 μg Cr/ml. Die Farbintensität der orangegelben Lösung gehorcht in einem Bereich von 0,1–1,0 μg Chrom/ml dem Lambert-Beerschen Gesetz. Der Einfluß von verschiedenen Säuren und Salzen auf die Reaktion wurde untersucht.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 160 (1958), S. 1-6 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Es wird eine Methode zur komplexometrischen Bestimmung von Natrium, Kalium und deren Summe beschrieben. Mit Hilfe eines Ionenaustauschers in der Mg-Form werden die Alkalimetalle quantitativ und stöchiometrisch gegen Magnesium ausgetauscht, welches dann mit Eriochromschwarz T als Indicator komplexometrisch bestimmt werden kann. Das Verfahren ist im Makro-, Halbmikro- und bei Beachtung bestimmter Vorsichtsmaßregeln auch im Mikromaßstab anwendbar. Bei Vorliegen von Natrium und Kalium nebeneinander wird deren Summe bestimmt. Durch Hinzuziehen der Kaliumbestimmung mit Tetraphenyloborat ist eine Natrium-Kalium-Trennung möglich. Das Resultat liegt nach 30 min vor; die reine Arbeitszeit beträgt etwa 10 min. Dies läßt die Methode zur Schnellbestimmung geeigneter erscheinen, als die vor kurzem beschriebene Natriumbestimmung durch Ionenaustausch gegen Kalium3. Die Methode zeichnet sich durch hohe Genauigkeit aus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...