Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 24 (1983), S. 213-215 
    ISSN: 1432-1920
    Keywords: Iohexol ; Cranial computed tomography ; Contrast enhancement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The commonly used contrast medium metrizoate (isopaque Cerebral®) or the new nonionic iohexol were injected intravenously for enhancement of cranial CT in a randomized double blind study. Each group consisted of 105 patients. No serious reactions occurred. Ten patients receiving metrizoate had minor reactions of mainly allergic type, whereas only one patient receiving iohexol reacted. No differences in enhancement efficiency could be observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 24 (1983), S. 201-204 
    ISSN: 1432-1920
    Keywords: Iohexol ; Cerebral angiography ; Contrast media
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The new non-ionic contrast medium iohexol was compared with Amipaque in selective cerebral angiography in a double blind study in 60 patients. There were no adverse reactions or reports of discomfort during the examinations or in the 24 h follow-up period. No differences were observed with regard to image quality or cerebral circulation time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-7373
    Keywords: astrocytoma ; 201thallium SPECT ; MRI ; MR spectroscopy ; chemotherapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Purpose To compare chemotherapy treatment monitoring in astrocytoma by 201thallium single photon emission computed tomography (SPECT) and photon magnetic resonance spectroscopy (1H-MRS) with magnetic resonance imaging (MRI), and to evaluate the influence of morphological tumor changes on cerebral 201thallium uptake and metabolic changes in 1H-MRS. Materials and methods Six patients with highly malignant astrocytomas were followed with quantitative 201thallium SPECT, MRI, and 1H-MRS during chemotherapy. Maximum follow-up included six examinations per patient by either method during 18 months. Criteria were set for: (1) regression (≥ 25% tumor reduction), (2) status quo (〈 25% reduction and 〈 25% increase), and (3) progression of disease (≥ 25% tumor increase). Results were compared with the clinical state of disease. Changes of tumor volume, contrast enhancement, necrosis, hemorrhage and edema on MRI were compared to changes in 201thallium uptake volumes and 1H-MRS metabolite ratios. Results Six patients were followed with a total of twenty-four examinations with 201thallium SPECT, MRI and 1H-MRS, respectively, between February 1997 and October 1998. Five patients developed clinical progression of disease, 4 out of 5 cases showed SPECT progression, 4 out of 5 cases MRI progression, and 1 out of 2 interpretable cases 1H-MRS progression at final assessment before clinical deterioration. During the phase of clinically stable disease; (A) the criterion for regression or status quo was met in 10 out of 13 assessments with SPECT, 11 out of 13 with MRI, and 8 out of 9 interpretable 1H-MRS; (B) the criterion for progression was met in 3 out of 13 with SPECT, 2 out of 13 with MRI, and 1 out of 9 interpretable 1H-MRS. The accuracy of SPECT, MRI, and 1H-MRS in identifying changes of tumor burden concordant with patients' clinical course was 78%, 83%, and 82%, respectively. SPECT regression was associated with MRI decrease of tumor size, contrast enhancement, edema and hemorrhage. SPECT progression was associated with MRI increase of the same parameters and the increase of necrosis. 1H-MRS regression was associated with decrease of edema. 1H-MRS progression was associated with increase of tumor size, hemorrhage, and increase or decrease of contrast enhancement. Conclusions Both 201thallium SPECT and 1H-MRS evaluation showed sensitivity for detection of astrocytoma progression. We did not find a higher accuracy of SPECT or MRS than of MRI in astrocytoma chemotherapy monitoring. Treatment induced MRI changes were associated with 201thallium uptake variations. 1H-MRS was difficult to apply for astrocytoma treatment monitoring. Improvements regarding size of measurement area such as multivoxel MRS and fat suppression pulses appeared desirable, and also the use of functional techniques with superior resolution such as dual isotope SPECT. However, our results suggest that 201thallium SPECT and 1H-MRS can provide additional information to MRI for chemotherapy efficacy evaluation in selected cases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗