Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • faeces  (2)
  • 3D range data  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Machine vision and applications 8 (1995), S. 79-84 
    ISSN: 1432-1769
    Keywords: Slit-ray projection ; Position-sensitive device ; 3D range data ; High-speed range finders
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Notes: Abstract A new system for high-speed and continuous 3D measurement is presented. It is based on the slit-ray projection method. The key component is the image plane constructed by a position-sensitive device (PSD) array that is horizontally un segmented and linear, but vertically numbered. All PSD row elements are attached to their respective analog signal processors. The analog signals are multiplexed and digitized by multiplexers and A/D converters at appropriate sampling intervals and stored in memory. By virtue of this configuration of the image plane, basis data for 3D measurement are acquired during only one scan of the slit ray at high speed in the form of memory addresses and data. Moreover, if we use large capacity and/or dual port memories, we can continuously obtain 3D range data for as many scenes as needed. The trial system has been implemented with a newly designed 128-channel PSD array and has verified our method, enabling us to obtain successive 3D range data at video rates with an error within±0.3%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-7446
    Keywords: diagnosis ; dog ; faeces ; latex agglutination ; occult blood ; serology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A reversed passive latex agglutination test (RPLA) using anti-canine haemoglobin (Hb) antibody was developed for detecting bleeding in the lower digestive organs in dogs, and its applicability as a simple test for faecal occult blood was assessed. In Ouchterlony's gel immunodiffusion test, the anti-canine Hb antibody used to sensitize the latex reacted with canine Hb but not with Hbs, plasmas or meat extracts from pigs, goats, sheep, cattle, horses or chickens, or with fish extracts. Using latex sensitized with 50 µg/mg of anti-canine Hb IgG antibody, the lowest limit of detection for canine Hb was 21 µg/ml, and the latex reacted negatively with all test specimens other than canine Hb. In an in vitro experiment with a mixture of canine faeces and erythrocytes, the antigenicity of the Hb was found to undergo only very slight changes even when the specimens were allowed to stand for 12 h at room temperature. Hb could not be detected by RPLA in any of four successive faecal samples from three experimental dogs after infusion of autologous blood (5, 3 or 1 ml) into the stomach. In 3 other experimental dogs given an infusion of autologous blood (5, 3 or 1 ml) into the ascending colon, the presence of Hb was confirmed by RPLA in all four successive faecal samples obtained from those which received 5 or 3 ml of blood and in all except that obtained following the first defecation from the animal which had received 1 ml of blood.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Veterinary research communications 22 (1998), S. 193-201 
    ISSN: 1573-7446
    Keywords: diagnosis ; dog ; ELISA ; faeces ; latex agglutination ; occult blood ; serology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Faecal haemoglobin (Hb) concentrations in apparently healthy experimental Beagle dogs and in dogs of various breeds kept in private households or at breeders were measured by reversed passive latex agglutination (RPLA) and enzyme-linked immunosorbent assay (ELISA) in an effort to define the physiological concentrations of faecal Hb in the dog. In 88% (53) of 60 experimental Beagle dogs (30 males and 30 females), the RPLA titres were 1:2 and 1:8 and the faecal Hb concentrations ranged from 40.0 to 431.5 (mean 184.1±92.6) μg/g faeces by ELISA. No significant difference was found in Hb levels or RPLA titres between males and females. Seven dogs (12%) had significantly greater RPLA titres and Hb concentrations by ELISA than the remaining dogs. In 84% (45) of the 53 dogs kept in private households or at breeders, the RPLA titres were 〉1:1 to 1:8 and the faecal Hb concentrations ranged from 7.1 to 456.7 (mean 137.5±128.7) μg/g faeces in ELISA. Eight of these dogs (15.1% of 53 dogs) had significantly greater RPLA titres and Hb concentrations by ELISA than the remaining dogs. There were no significant differences between the Beagles and dogs kept in private households or at breeders. In conclusion, in 98 (86.7% of 113) dogs the physiological concentrations of RPLA titres were 〉1:1 to 1:8 and the faecal Hb concentrations were 143.5–185.1 μg/g (95% confidence level). Approximately 13.3% of apparently healthy dogs had higher faecal Hb concentrations, suggesting the presence of subclinical haemorrhages. Four dogs suffering from colorectal cancer also had high faecal Hb concentrations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...