Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Machine vision and applications 8 (1995), S. 79-84 
    ISSN: 1432-1769
    Keywords: Slit-ray projection ; Position-sensitive device ; 3D range data ; High-speed range finders
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Notes: Abstract A new system for high-speed and continuous 3D measurement is presented. It is based on the slit-ray projection method. The key component is the image plane constructed by a position-sensitive device (PSD) array that is horizontally un segmented and linear, but vertically numbered. All PSD row elements are attached to their respective analog signal processors. The analog signals are multiplexed and digitized by multiplexers and A/D converters at appropriate sampling intervals and stored in memory. By virtue of this configuration of the image plane, basis data for 3D measurement are acquired during only one scan of the slit ray at high speed in the form of memory addresses and data. Moreover, if we use large capacity and/or dual port memories, we can continuously obtain 3D range data for as many scenes as needed. The trial system has been implemented with a newly designed 128-channel PSD array and has verified our method, enabling us to obtain successive 3D range data at video rates with an error within±0.3%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1741-0444
    Keywords: Fetal magnetocardiogram ; Atrial flutter ; Atrial fibrillation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Two cases of fetal tachycardia are reported: atrial flutter and fibrillation. The waveforms from each case were detected by fetal magnetocardiograms (FMCGs) using a 64-channel superconducting quantum interference device (SQUID) system. Because the magnitude of supraventricular arrhythmia signals is very weak, two subtraction methods were used to detect the fetal MCG waveforms: subtraction of the maternal MCG signal, and subtraction of the fetal QRS complex signal. It was found that atrial-flutter waveforms showed a cyclic pattern and that atrial-fibrillation waveforms showed f-waves with a random atrial rhythm. Fast Fourier transform analysis determined the main frequency of the atrial flutter to be about 7 Hz, and the frequency distribution of atrial fibrillation consisted of small, broad peaks. To visualise the current pattern, current-arrow maps, which simplify the observation of pseudo-current patterns in fetal hearts, of the averaged atrial flutter and fibrillation waveforms were produced. The map of the atrial flutter had a circular pattern, indicating a re-entry circuit, and the map of the atrial fibrillation indicated one wavelet, which was produced by a micro-re-entry circuit. It is thus concluded that an FMCG can detect supraventricular arrhythmia, which can be characterised by re-entry circuits, in fetuses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...