Abstract Intracavity second-harmonic generation of continuous-wave chemical oxygen-iodine laser emission has been studied. A chemical oxygen-iodine laser with a maximum fundamental-wave output power of about 10 W in a concentric cavity was used. Experiments were performed for three types of optical cavities using an 1 cm LBO crystal. Second-harmonic output of 12.4 W, 6.2 W, and 5.2 W, effective extraction efficiencies of 155.0% 65.9%. and 55.3%, and single-pass conversion efficiencies of 0.615%, 0.685%, and 0.655% were obtained for the respective cavities. A comparison of these results of coupling by frequency doubling with the results of fundamental-wave output coupling of this system is also presented.