Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Miniaturized HPLC ; Post-Column Extraction Detection ; Segmented-Flow Open-Tubular Reactors ; Membrane Phase Separator ; Anti-Cancer Drugs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract An on-line, post-column, extraction system suitable for use with miniaturized HPLC (0.7–1 mm i.d. columns) is described. The system consists of a 30° angle segmenting tee, a PTFE extraction coil of variable length and a membrane phase separator. The internal volume of the phase separator is less than 1 μl. The total variance contribution of the system is between 1 and 6 sec2. The determination of the anti-cancer drugs VP 16 and VM 26 in urine by means of reversed-phase HPLC and fluorescence detection, using both on-column preconcentration and the present miniaturized post-column extraction system is presented as an application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 11-14 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Fluorescence ; Ion-pair extraction ; Amines ; Post-column reaction ; Auto-analyser ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detection system is described which is based on fluorescent ion-pair formation between tertiary amine drugs and dimethoxyanthracene sulphonate. A dynamic micro-extraction principle is then used to isolate the ion-pairs from the excess reagent. The band broadening of this extraction detector was kept below 20% using standard auto-analyser equipment. With the enhanced selectivity and sensitivity of this approach it was possible to analyse chloropheniramine in urine at ppb concentrations using a pre-column clean-up trace enrichment step.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Coupled LC-GC ; Retention gap ; LC trace enrichment ; Aqueous samples ; Organic pollutants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Trace enrichment for the GC analysis of a series of chlorinated pesticides and polychlorinated biphenyls (PCBs) in aqueous samples has been achieved through a simple on-line technique involving sorption on an LC micro-precolumn followed by direct elution into a gas chromatograph with hexane. A 5-m retention gap coupled to the capillary GC column served as the recipient of a relatively large sample volume (ca. 100 μl) introduced into the GC. Partially concurrent solvent evaporation during sample introduction allowed a large sample capacity. Recoveries of more than 95% were observed for the majority of the compounds studied. Using 1.0 ml aqueous samples, detection limits of less than 1 ppt were found. The applicability of the developed method was demonstrated for a river water sample.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...