Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1211
    Keywords: Key words Inflammatory bowel ; Crohn's ; Ulcerative colitis ; Interleukin-4 receptor ; Association
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract  Genetic linkage analysis in families with multiple cases of inflammatory bowel disease (IBD) has mapped a gene which confers susceptibility to IBD to the pericentromeric region of chromosome 16 (IBD1). The linked region includes the interleukin(IL)-4 receptor gene (IL4R). Since IL-4 regulation and expression are abnormal in IBD, the IL4R gene is thus both a positional and functional candidate for IBD1. We screened the gene for single-nucleotide polymorphisms (SNPs) by fluorescent chemical cleavage analysis, and tested a subset of known and novel SNPs for allelic association with IBD in 355 families, which included 435 cases of Crohn's disease and 329 cases of ulcerative colitis. No association was observed between a haplotype of four SNPs (val50ile, gln576arg, A3044G, G3289A) and either the Crohn's disease or ulcerative colitis phenotypes using the transmission disequilibrium test. There was also no evidence for association when the four markers were analyzed individually. The results indicate that these variants are not significant genetic determinants of IBD, and that the IL4R gene is unlikely to be IBD1. Linkage disequilibrium analyses showed that the val50ile and gln576arg variants are in complete equilibrium with each other, although they are separated by only about 21 kilobases of genomic DNA. This suggests that a very dense SNP map may be required to exclude or detect disease associations with some candidate genes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 1227-1233 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A combined magnetic sector-time-of-flight instrument has been constructed and used with both continuous (liquid secondary ion mass spectrometry and electrospray ionization) and pulsed (matrix-assisted laser desorption/ionization) ion sources. The design includes provision for both low- and high-energy gas collision induced decompositions and orthogonal acceleration of the product ions into the time-of-flight mass analyser. Tandem mass spectra may be acquired for singly and multiply charged precursor ions and reliable mass measurements are easily obtained. Product-ion mass spectra are quite reproducible regardless of any instability in the precursor ion beam intensity.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...