Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (24)
  • intestinal permeability  (3)
  • 1
    ISSN: 1573-904X
    Keywords: Caco-2 ; unstirred water layer ; intestinal permeability ; steroids ; cell culture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Caco-2 monolayers grown on Transwell polycarbonate membranes have been characterized as a valuable tool in drug transport studies. Despite the clear advantages of this system, the lack of stirring may create an unstirred water layer (UWL) whose resistance may limit the transcellular transport of lipophilic molecules. The objective of this study was to evaluate a novel diffusion cell where the transport buffer is mixed by gas lift and to determine the mixing flow rate needed to reduce the thickness (h) of the UWL adjacent to cell monolayers. The transport of the leakage marker, mannitol, remained at least 15-fold lower than the flux of testosterone, indicating that the stirring flow rates used did not affect the integrity of the monolayers. The permeability (P) of testosterone (log PC 3.13) across monolayers mounted on this diffusion cell was 4.07, 10.90, and 14.18 × 10−5 cm/sec at flow rates of 0, 15, and 40 ml/min, respectively, and the apparent UWLs were calculated to be 1966, 733, and 564µm. P and h in the stagnant Transwell were 3.08 × 10−5 cm/sec and 2597 µm, respectively. On the other hand, h was significantly smaller in the unstirred, cell-free membranes than in their cell-containing counterparts. P was correlated with lipophilicity and, in the case of the more lipophilic compounds, with the mixing flow rate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 5 (1988), S. 372-376 
    ISSN: 1573-904X
    Keywords: In vitro apparatus ; diffusion cell ; intestinal permeability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A new diffusion cell, derived from the Ussing chamber, was developed for the measurement of tissue permeability. This cell incorporates the attributes of using a single material and laminar flow across the tissue surface. In addition, the design allows the cell to be manufactured in a wide range of sizes to allow optimization of surface area to volume for a variety of tissues. The apparatus is applicable to the evaluation of transport of compounds through mucosal/epithelial barriers, i.e., gastrointestinal tissue. Active transport, permeability enhancers, enzymatic degradation, and absorption in various tissue sections can be explored. Preliminary data are consistent with the expected effects of molecular size and partition coefficient of a transported molecule on permeability in epithelial tissue. In addition, active transport of D-glucose and inhibition by phloridzin and ouabain can be demonstrated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 9 (1992), S. 1580-1586 
    ISSN: 1573-904X
    Keywords: intestinal permeability ; partition coefficient ; jejunum ; colon ; species differences
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The in vitro permeability of a series of both hydrophilic and lipophilic compounds, as defined by the octanol/water partition coefficient, was measured in four segments of rabbit, monkey, and dog intestine using a side-by-side diffusion cell. A linear relationship was established for tissue resistance to hydrophilic compound diffusion in jejunum and colon among rabbit, monkey, and dog. The results suggest that rabbit jejunum is twice as permeable as monkey and dog jejunum. The colonic tissues of monkey, rabbit, and dog demonstrate similar permeabilities. Measuring the permeabilities of different tissues with compounds of similar physicochemical properties allows comparison of tissue restriction to transport. Thus, in vitro permeability measurements may be used to investigate physiological differences of various intestinal tissue segments that influence tissue permeability. Investigating the permeability of different intestinal segments from various species could allow the identification of an appropriate in vitro intestinal permeability model that will lead to the prediction of intestinal absorption in humans, eliminating the need for extensive and often misleading in vivo animal testing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 102-103 
    ISSN: 0935-6304
    Keywords: HPLC ; Capillary electrophoresis (CE) ; Laser desorption mass spectrometry ; Synthetic peptides ; Purity determination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 753-755 
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; Nitrosamines ; Subambient temperature ; syn and anti isomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The separation of a selected group of naturally occurring, heterocyclic nitrosoamino acids was achieved by capillary zone electrophoresis and the resolution of the syn and anti conformers improved as the temperature was lowered to 5 °C. The double peaks observed for each nitrosoamino acid are probably caused by the slow kinetics of conformational isomerism. The experimental setup consisted of a P/ACE 5510 electrophoresis system, a 57 cm polyacrylamidecoated capillary, and a 10 mM phosphate buffer, pH 7.2, containing 2 mM of 3-(N-N-dimethylmyristylammonio)propanesulfonate (DMMAPS) and 0.1% Tween 20. Our study shows that (a) the lower the temperature, the greater the resolution and the longer the migration times; and (b) different nitrosoamino acid conformers were resolved at different temperatures because of differences in the rate of isomerization. For example, the conformers of N-nitrosothiazolidine-4-carboxylic acid were partially resolved at 30 °C while those of N-nitrosoproline were well resolved at the same temperature.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 312-316 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The stoichiometry of a noncovalent, hydrogen-bonded supramolecular complex, hub(M)3·RCA3, was characterized using electrospray ionization from chloroform. The intact (1:3) complex was observed in the negative-ion mode as a Cl--bound species using Ph4PCl as the source of the charge donor. Collisionally and thermally induced dissociation of the (1:3) complex resulted in the simultaneous loss of all the three RCA units, indicating a cooperative binding of RCA units in the (1:3) complex. These results suggest that the attachment of small, organic-soluble ions may be a useful technique for mass spectrometric characterization of neutral supramolecular complexes that are stable or soluble only in non-polar organic solvents.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 171-174 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic chromatography (MEKC) ; Micelle-aqueous partition coefficients ; Hydrophobic solutes ; Polyacrylamide-coated columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A micellar electrokinetic chromatography method is presented for the determination of the partition coefficient for the distribution of nonpolar and moderately polar solutes between the micelle and the aqueous phases in aqueous micellar solutions. In comparison with the literature the method is, theoretically and experimentally, the most straightforward for this application. An equation is derived for the determination of the partition coefficient in a coated fused silica capillary, with neglible electroosmotic flow, from simple measurements of the migration times of solutes and a marker for micelle migration. The advantages and limitations of this method are discussed. The method is tested by using sodium dodecylsulfate (SDS) surfactant and naphthalene, benzene, toluene, and phenol solutes. Micellar electrokinetic chromatography in coated columns isideally suited for the separation of hydrophobic solutes in aqueous samples.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0935-6304
    Keywords: Chlorobiphenyl congeners ; Aroclors ; DB-XLB phase ; HP-5/HT-5 serial coupled phases ; GC-ECD ; GC-MS-SIM ; GC-Ion Trap MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Three HRGC systems (1: 30m DB-XLB capillary with MS-SIM detection; 2: 60m DB-XLB capillary with full-scan, ion-trap MS detection; and 3: Parallel dual-column DB-17 and series-coupled HP5/HT5 with ECD detection) were used to completely characterize multiple lots of 8 different-numbered Aroclor mixtures by quantitative calibration against 9 solutions containing primary standards of all 209 PCB congeners. Despite lower absolute sensitivity and more Aroclor congener coelutions than the dual-column ECD system, the MS systems enabled measurement of more congeners per Aroclor since their greater linear response range did not require dilution of samples and standards. Pairs of different lots of Aroclors 1248 and 1254 displayed markedly different proportions of congeners, and the 1254 pair displayed strong differences in the extent of ortho-chlorine substitution. The tables of congener weight percent distributions among Aroclors are more comprehensive and quantitatively precise than those of prior publications. However, the limitations of single-level calibration precluded measurement of all congeners to the ±10% accuracy desirable for establishing these Aroclors as secondary standards for comprehensive, quantitative congener-specific PCB analysis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 373-378 
    ISSN: 0935-6304
    Keywords: Electrophoresis ; electrophoretic mobilities ; CZE ; MEKC ; peptides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A computer model is presented for the prediction of the electrophoretic mobilities of peptides from physical constants derived from their amino acid sequences. The model assumes that the electrophoretic mobility can be represented by a product of four functions according to the relation:  lcomp= l(L)w(W)q(Q)c(CC), where L (a length parameter) is represented by the number of amino acid residues of the peptide, W (a width parameter) is represented by the average residue mass, Q = the charge of the peptide, and CC = the position of the center of charge relative to the center of mass. The model was used to calculate the electrophoretic mobilities of peptides in a 50 mM phosphate buffer at pH 2.5. Sixty-four test peptides ranging in size from 2 to 39 amino acid residues were used for this study. The calculated mobilities show excellent correlation with experimental measurements with a correlation coefficient greater than 0.98.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 533-540 
    ISSN: 0935-6304
    Keywords: Chlorobiphenyl congeners ; Aroclor 1254 ; DB-XLB phase ; GC-MS-SIM ; PCB 126 ; toxic equivalency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Complete PCB congener distributions in a panel of Aroclor mixtures were previously obtained by combining data from several HRGC systems. In that study quantitation of minor components may have been unreliable due to single level calibration against high levels of individual congener standards. Two lots of Aroclor 1254 had markedly different congener distributions. In this study, the design and performance of a congener-specific PCB analysis method employing GC-MS-SIM detection of congeners separated on a DB-XLB capillary column are discussed. Quantitation is carried out against a 6-level inclusive standard curve of a mixture of 144 congeners found in Aroclors. A separate procedure to measure trace levels of PCB 126 in Aroclors using the same system, combined with levels initially acquired for other congeners, facilitates estimation of TEQ values (Toxic Equivalencies of the PCB mixtures to 2,3,7,8-TCDD). PCB congener profiles of 15 Aroclor 1254 mixtures are presented. These profiles show that the less common, high TEQ variety of Aroclor 1254 was manufactured by an atypical, two-stage chlorination process that was apparently used during the final 1% of Aroclor 1254 production (ca. 1974-1976).
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...