Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (3)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 2 (1988), S. 244-245 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1988), S. 415-417 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Measurements of the dissociative ionization cross-sections of CO, CO2, NO and N2O molecules for electrons from 20 up to 1000 eV were performed. Total collection of ions was achieved by using a specially constructed cycloidal mass spectrometer, an ion source without slit and a collector with large area. In that open ion source the effusion molecular beam formed by a capillary was crossed by the electron beam. Owing to such parameters of the mass spectrometer the mass discrimination effects were reduced. At the ionization of CO molecules, the ions CO+, C+, O+ and CO2+ were registered; at CO2, the ions CO2+, CO+, O+, C+ and CO22+; at NO, the ions NO+, N+, O+ and NO2+; at N2O, the ions N2O+, NO+, N2, O+, O+, (N+, N2+ 2) and N2O2+. The relative values of the partial cross-sections were normalized to the absolute total ionization cross-sections obtained by Rapp and Englander-Golden.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1988), S. 455-456 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper shows the results of the experiment on gas dynamic transport of helium from outside through the skin to the lungs of man in conditions of changing temperature and humidity of surroundings. The apparatus includes: an elastic bag in which the whole subject can be saturated by helium; a heating and refrigerating system; a respiratory system; an introduction system to the mass spectrometer; and a mass spectrometer with an ion detector of high sensitivity. The temperature of the surroundings varied from 24°C up to 44°C and humidity varied from 50% up to 95%. The temperature of skin varied from 25°C up to 37°C. Also the temperature oscillations of the period from 1 to 3 min were generated. In effect, those oscillations corresponded with the oscillations of He concentration in the expired air. At the higher level of humidity of the surroundings, a higher concentration of helium in the expired air was observed. At 100% He concentration in the bag, the minimal He concentration in the expired air was 40 ppm and maximal 110 ppm. In the opinion of the authors the thermoregulation system in the body of the subject played a significant role in the observed process of gas transport.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...