Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1975-1979  (11)
  • Analytical Chemistry and Spectroscopy  (10)
  • Auxin uptake  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Planta 142 (1978), S. 211-219 
    ISSN: 1432-2048
    Schlagwort(e): Auxin transport ; Auxin uptake ; Pisum
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie
    Notizen: Abstract 1. The uptake of indol-3-yl acetic acid ([1-14C]IAA, 0–2.0 μM) into light-grown pea stem segments was measured under various conditions to investigate the extent to which mechanisms of auxin transport in crown gall suspension culture cells (Rubery and Sheldrake, Planta 118, 101–121, 1974) are also found in a tissue capable of polar auxin transport. — 2. IAA uptake increased as the external pH was lowered. IAA uptake was less than that of benzoic acid (BA), naphthylacetic acid (NAA) or 2,4 dichlorophenoxyacetic acid (2,4D) under equivalent conditions. TIBA enhanced net IAA uptake through inhibition of efflux, and to a lesser extent, also increased uptake of NAA and 2,4D while it had no effect on BA uptake. — 3. Both DNP and, at higher concentrations, BA, reduced IAA uptake probably because of a reduction of cytoplasmic pH. However, low concentrations of both BA and DNP caused a slight enhancement of IAA net uptake, possibly through a reduction of carrier-mediated IAA efflux. In the presence of TIBA, the inhibitory effects of DNP and BA were more severe and there was no enhancement of uptake at low concentrations. — 4. Non-radioactive IAA (10 μM) reduced uptake of labelled IAA but further increases in concentration up to 1.0 mM produced first an inhibition (0–10 min) of labelled IAA uptake, followed by a stimulation at later times. Non-radioactive 2,4 D decreased, but was not observed to stimulate, uptake of labelled IAA. In the presence of TIBA labelled IAA uptake was inhibited by non-radioactive IAA regardless of its concentration. — 5. Sulphydryl reagents PCMB and PCMBS promoted or inhibited IAA uptake depending, respectively, on whether they penetrated or were excluded from the cells. The penetrant PCMB also reduced the promotion of labelled IAA uptake by TIBA or by high concentrations of added non-labelled IAA. — 6. Our findings are interpreted as being consistent with the diffusive entry of unionised IAA into cells together with some carrier-mediated uptake. Auxin efflux from the cells also appears to have a carrier-mediated contribution, at least part of which is inhibited by TIBA, and which has a capacity at least as great as that of the uptake carrier. The data indicate that pea stem segments contain cells whose mechanisms of trans-membrane auxin transport fit the model of polar auxin transport proposed from experiments with crown gall suspension cells, although differences, particularly of carrier specificity, are apparent between the two systems.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 4 (1977), S. 42-47 
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Quantitative analytical procedures for the analysis of phenylbutazone and tolbutamide levels in plasma have been developed which involve the addition of deuterium labeled internal standards to plasma followed by extraction and direct sample insertion into a mass spectrometer operating under chemical ionization conditions. Peak height ratios used to calculate plasma levels were determined by using either selected ion monitoring or repetitive scan data. The scan approach was used in a related procedure for the simultaneous determination of tolbutamide and two metabolites from urine. The accuracy, precision and sensitivity of the direct sample insertion approach to drug level measurement has been determined. Examples are given of data obtained in the course of pharmacokinetic studies in which this analytical approach appears to offer advantages in the analysis of multicomponent mixtures encountered in drug-drug interaction studies.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 5 (1976), S. 154-168 
    ISSN: 0049-8246
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: The bremsstrahlung spectrum from a thick specimen bombarded with 20 ke V electrons is studied with emphasis on the shape rather than the absolute intensity in the energy range 1-10 keV. Monte Carlo calculations are described in detail and used to compare the absorption corrections for characteristic and continuous (bremsstrahlung) radiation from a thick specimen and to determine the extent to which anisotropy modifies the intensity distribution of the continuum. The absorption corrections are found to differ by roughly 5% for f(χ) = 0.5 and 10% for f(χ) = 0.2, but it is shown that the ratio of the corrections can be predicted by using the ratio of two Philibert-type formulae. Anisotropy has little influence on the absorption correction but changes in atomic number or geometry may result in the intensity distribution being altered by typically 5-10% across the energy range 1-10keV. Numerical integration gives values for the generated brems-strahlung intensity which are used in constructing an expression to represent the functional form of the background. Although experimental spectra confirm this to be superior to the combination of Kramers' law and a characteristic absorption expression, several sources of error at low energies, including bremsstrahlung from the Be window, are pointed out and improvements suggested. In order to eliminate the principal uncertainty, that of the overall efficiency curve for a Si(Li) detector and pulse-processor, it is recommended that a stored spectrum be used as a ‘background standard’ for explicit background corrections. Errors are then reduced to the 0.1% absolute concentration level, which is suitable for quantitative analysis.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 0030-493X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The kinetics of formation of [C3H5]+[M — CH3]+, [C3H4]+·[M — CH4]+· and [C2H4]+·[M — C2H4]+· from but-1-ene, cis- and trans-but-2-ene, 2-methylpropene, cyclobutane and methylcyclopropance following field ionisation have been determined as a function of time 20 (or 30) picoseconds to 1 nanosecond and at two points in the microsecond time-frame. The results are consistent with the supposition that at the shortest accessible times (20 to 30 picoseconds) the structure of the [C4H8]+· molecular ion qualitatively resembles that of its neutral precursor, but suggest that prior to decomposition within nanoseconds the various molecular ions (excepting cyclobutane where the processes are slower) attain a common structure or mixture of structures. Reaction pathways of the presumed known ion structures are delineated from the nature of decompostion at the shortest times.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 13 (1978), S. 386-388 
    ISSN: 0030-493X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The internal energies of [C3H7]+ ions contributing to the metastable peak [C3H7]+ → [C3H5]+ + H2 are higher (by perhaps 〉 100 kJ mol-1) than those of the ion contributing to the threshold current in appearance energy measurements on [C3H5]+. The measured appearance energy may lead to an underestimation of the activation energy, i.e. negative ‘kinetic shift’, due to quantum, mechanical tunnelling. The distribution of energy released in the decomposition can be explained on the basis that much of the reverse activation energy and a statistical proportion of the excess energy is released as translation.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 10 (1975), S. 1171-1173 
    ISSN: 0030-493X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The observation of doubly charged ions in field ionization with blade or wire emitters does not in itself indicate that high excitation energies (≥ 17 eV) are accessible through gas phase ionization with such emitters.
    Zusätzliches Material: 1 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1979), S. 337-340 
    ISSN: 0030-493X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The partition of reverse activation energy in hydrogen rearrangements is considered in terms of atomic motions composing the transition state reaction coordinate. It is shown how this approach predicts that, in general, elimination of H2 from any small ion (as defined in the paper) is likely to be characterized by partition of significant proportions of any reverse activation energy as translational energy of the products. Hydrogen rearrangements in large ions leading to fragments of comparable mass are much less likely to partition reverse activation energy into product translation.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 11 (1976), S. 440-442 
    ISSN: 0030-493X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Graphs are presented which can be used to correct metastable peak widths for both instrumental broadening and translational energy spread of the parent ion.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 11 (1976), S. 835-837 
    ISSN: 0030-493X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: It is suggested that division of the rates of molecular ion decomposition by the measured mass-resolved molecular ion current be adopted as the standard method of normalizing these data obtained through the field ionization kinetics technique.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 6 (1977), S. 94-103 
    ISSN: 0049-8246
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: Pile-up rejection is commonly achieved through use of an auxiliary inspection channel with short time constants but low energy events can be missed because of electronic noise. A formula is derived to predict the detection efficiency of such a channel and the effect of adjusting the discriminator threshold or changing the time constants is demonstrated. When pulses are missed, spectrum distortion and counting losses are greater than would be predicted from the specified pulse pair resolution time so it is important to optimize the inspector adjustment. A mathematical analysis leads to formulae which can be used to correct for residual counting losses and sum peaks, and the relationship between empirical parameters obtained for these formulae and time constants in the electronics is demonstrated. The present state of the art in noise performance dictates that 1 μs is about the best resolution time that can be achieved for 1 ke V pulses. For further improvements, a fast beam switching technique could be used which would improve pulse pair resolution by a factor of three or more and thus afford adequate protection for the very low energy pulses that would be encountered with thin-window or windowless solid-state detectors.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...