Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 25.70Np  (1)
  • Body composition  (1)
  • Body water  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 18 (1992), S. 322-326 
    ISSN: 1432-1238
    Schlagwort(e): Body water ; Bioimpedance
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: To evaluate the relationship between changes in body bioelectrical impedance (BI) at 0.5, 50 and kHz and the changes in body weight, as an index of total body water changes, in acutely ill surgical patients during the rapid infusion of isotonic saline solution.Design: Prospective clinical study.Setting: Multidisciplinary surgical ICU in a university hospital.Patients: Twelve male patients treated for acute surgical illness (multiple trauman=5, major surgeryn=7). Selection criteria: stable cardiovascular parameters, normal cardiac function, signs of hypovolemia (CVP≤5 mmHg, urine ouput 〈1 ml/kg×h).Interventions: After baseline measurements, a 60 min fluid challenge test was performed with normal saline solution, 0.25 ml/kg.Measurements and results: Body weight (platform digital scale), total body impedance (four-surface electrode technique; measurements at 0.5, 50 and 100 kHz) and urine output. Fluid retention induced a progressive decrease in BI at 0.5, 50 and 100 kHz, but the changes were significant for BI 0.5 and BI 100 only, from 40 min after the beginning of the fluid therapy onwards. There was a significant negative correlation between changes in water retention and BI 0.5, with individual correlation coefficients ranging from −0.72 to 0.95 (p〈0.01–0.0001). The slopes of the regression lines indicated that for each kg of water change, there was a mean decrease in BI of 18 ohm, but a substantial inter-individual variability was noted.Conclusion: BI measured at low frequency can represent a valuable index of acute changes in body water in a group of surgical patients but not in a given individual
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European journal of pediatrics 152 (1993), S. 222-225 
    ISSN: 1432-1076
    Schlagwort(e): Body composition ; Anthropometry ; Bioelectrical impedance analysis ; Cystic fibrosis
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The nutritional status of cystic fibrosis (CF) patients has to be regularly evaluated and alimentary support instituted when indicated. Bio-electrical impedance analysis (BIA) is a recent method for determining body composition. The present study evaluates its use in CF patients without any clinical sign of malnutrition. Thirty-nine patients with CF and 39 healthy subjects aged 6–24 years were studied. Body density and midarm muscle circumference were determined by anthropometry and skinfold measurements. Fat-free mass was calculated taking into account the body density. Muscle mass was obtained from the urinary creatinine excretion rate. The resistance index was calculated by dividing the square of the subject's height by the body impedance. We show that fat-free mass, mid-arm muscle circumference and muscle mass are each linearly correlated to the resistance index and that the regression equations are similar for both CF patients and healthy subjects.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1434-601X
    Schlagwort(e): 25.70z ; 25.70Jj ; 25.70Np
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract The light charged particles emitted in the40Ar+68Zn reaction performed at 14.6, 19.6 and 35 MeV/nucleon have been studied inclusively. The energy spectra have been analysed in terms of preequilibrium emission, moving source and coalescence models. A complete coherence between the present data and those obtained separately from heavy fragment studies is achieved. These data are consistent with the onset of projectile fragmentation between 20 and 35 MeV/nucleon correlated with the formation of a highly excited region of the nuclear system inducing light particle emission. The other sources of light particles can be interpreted as statistical and sequential decay of the quasi projectile.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...