Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel: DFG Deutsche Nationallizenzen  (3)
  • 1990-1994  (3)
  • Chemical Engineering  (2)
  • Micropuncture
Datenquelle
  • Artikel: DFG Deutsche Nationallizenzen  (3)
Materialart
Erscheinungszeitraum
Jahr
  • 1
    ISSN: 1432-2013
    Schlagwort(e): Rat ; Renal function ; Micropuncture ; Blood gases ; Anaesthesia ; Thiopentone ; Thiobutabarbitone
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The thiobutabarbitone(TB, Inactin)-anaesthetised rat is an extremely widely used preparation for the study of renal function at the whole-organ and nephron levels. The recent withdrawal of TB from the market has made it essential to find an anaesthetic producing experimental conditions as similar as possible to TB to allow comparison of past and future data. Blood gas analysis, clearance and micropuncture studies were therefore performed in rats anaesthetised with TB or the related thiobarbiturate thiopentone (TP) (both 100 mg/ kg body weight) to establish whether the latter meets this requirement. Both barbiturates caused similar transient respiratory depression and acidosis. Mean values (TP versus TB) over the total 8-h observation period for glomerular filtration rate (0.94 versus 1.05 ml/min), urine flow (3.8 versus 4.4 μl/min) and K+ excretion (0.98 versus 1.18 μmol/min) were slightly lower (P〈0.05) in TP rats, whereas renal blood flow (6.26 versus 6.24 ml/min), filtration fraction (0.31 versus 0.34) and Na+ excretion (0.11 versus 0.098 μmol/min) did not differ. The single-nephron filtration rate (SNGFR) (42.1 versus 41.1 nl/min) and fractional reabsorption (42% versus 47%), both measured in the proximal tubule, did not differ, although in the TP group SNGFR rose with time (4.4%/h) whereas the fractional reabsorption did not change significantly; in the TB group SNGFR was constant but fractional reabsorption declined with time (1.5%/h). Fractional reabsorption up to the distal convoluted tubule declined with time, this was more pronounced in the TP group. SNGFR measured at this site did not differ between TP and TB (30.3 versus 30.1 nl/min) but increased with time with TP (2.7%/h). Although renal function under TP is somewhat less stable than under TB, the differences are minor and, given that the latter is also characterised by non-steady-state conditions, it is concluded that TP is a reasonable replacement for TB.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 39 (1993), S. 1335-1341 
    ISSN: 0001-1541
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Equations introduced here identify measurement biases and process leaks, when gross errors exist in measured process variables and the variance-covariance matrix of the measurements, Σ, is unknown. Σ is estimated by the sample variance, S, using process data.For an unknown Σ, the global test statistic is the well-known Hotelling T2 statistic. Its power function has a noncentral F-distribution. For component tests used for specific identification of measurement biases and nodal leaks, two tests are presented with Σ unknown. The first test is independent of the number of component tests, k, and is given by a statistic with an F-distribution. The second test depends on k and has a student t-distribution. The power functions for both component tests are provided. Process examples and a Monte Carlo simulation study presented demonstrate the use and performance of these statistical equations in identifying biases and process leaks.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 38 (1992), S. 563-572 
    ISSN: 0001-1541
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: A new approach to gross error detection provides unbiased estimates and 100(1-α)% simultaneous confidence intervals of process variables when biased process measurements and process leaks exist. Presented in this article are estimation equations for process variables, as well as equations that help identify biased measurements and process leaks. These equations include the power function for a global test, and two types of α-level component tests and their power functions. Important strengths and weaknesses of this approach are compared to those of the serial compensation strategy, in particular, by varying the significance level (α), the variance-covariance matrix (Σ), the size of measurement bias (δ), the number of biased variables, and the sample size (N). Accuracy of δ estimation and performance in detecting the presence of process leaks (γ) are also evaluated and compared. The proposed approach has unique features that can provide a basis for improving the reconciliation of variables in process operations.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...