Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (7)
  • Chemical Engineering  (4)
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 38 (1992), S. 1593-1608 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A huge amount of data is collected by computer monitoring systems in the chemical process industry. Such tools as principal component analysis and partial least squares have been shown to be very effective in compressing this large volume of noisy correlated data into a subspace of much lower dimension than the original data set. Because most of what is eliminated is the collinearity of the original variables and the noise, the bulk of the information contained in the original data set is retained. The resulting low dimensional representation of the data set has been shown to be of great utility for process analysis and monitoring, as well as in selecting variables for control. These types of models can also be used directly in control system design. One way of approaching this is to use the loading matrices as compensators on the plant. Some advantages of using this approach as part of the overall control system design include automatic decoupling and efficient loop pairing, as well as natural handling of nonsquare systems and poorly conditioned systems.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 6 (1979), S. 187-190 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Quantification of low levels of psychotropic drugs (10-7 to 10-9 g ml-1) in small volumes of plasma requires sensitive and accurate methods. Validation of these methods is best achieved by comparing results obtained using several techniques. In this study, amphetamine levels in plasma were measured using gas chromatography mass spectrometry and radioimmunoassay. Correlation of the results obtained by the two methods was found to be positive and high (R = 0.9822). The average coefficient of variation between assays for gas chromatography mass spectrometry was 5.8% and for radioimmunoassay was 12.3%, while the average coefficient of variation within assays for gas chromatography mass spectrometry was 4.9% and for radioimmunoassay 6.9%. Although gas chromatography mass spectrometry was 1.9 times more sensitive than radioimmunoassay, for most purposes, the convenience of the radioimmunoassay method outweighs the technical superiority of gas chromatography mass spectrometry.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Brookfield, Conn. : Wiley-Blackwell
    Journal of Vinyl and Additive Technology 1 (1995), S. 241-249 
    ISSN: 0193-7197
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Semiempirical Molecular Orbital Calculations (MNDO AM1) support kinetic results concerning the molecular mechanism of thermal degradation of PVC and show that under special conditions radical and ionic mechanisms are also possible. The degradation of poly(vinyl chloride) is a complex chain dehydrochlorination that consists of an initiation process to generate an active intermediate followed by chain reactions that generate additional active intermediates with progressively increased numbers of double bonds. Each intermediate partitions between an intermediate with one more double bond and a stable conjugated polyene with the same number of double bonds. At low and moderate temperatures thermal degradation of PVC in an inert atmosphere is a succession of molecular concerted reactions. The initiation process is a 1,2-elimination through a four center transition state requiring a synperiplanar conformation. There are two main chain reactions: the first is a 1,4-elimination from allylic chlorine atoms and methylenes cis to a double bond through a transition state of six centers; the second is a 1,3-rearrangement of hydrogen atoms catalyzed by hydrogen chloride. The chain reaction is interrupted when a relatively stable trans double bond is formed and no hydrogen chloride is present to catalyze trans-cis isomerization or 1,3-rearrangement. Macro carbocations formed by heterolysis of carbon-halogen bonds in the presence of strong Lewis acids react much faster than does the original PVC in concerted elimination by 1,2-syn or 1,4-cis mechanisms, promoting a so-called catastrophic, very fast degradation. Macro radicals formed by thermal homolysis, irradiation or reaction with promoters can also promote very fast hydrogen chloride elimination because of a special mechanism consisting of a 1,2-rearrangement of a chlorine atom followed by a concerted 1,3-elimination through a five center transition state.
    Additional Material: 4 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Brookfield, Conn. : Wiley-Blackwell
    Journal of Vinyl and Additive Technology 12 (1990), S. 136-141 
    ISSN: 0193-7197
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Process Engineering, Biotechnology, Nutrition Technology
    Notes: During the past decade, advances in both hardware and software have made NMR spectroscopy an enormously powerful analytical technique. In this paper, the author presents examples of the use of NMR in support of vinyl stabilizer research; he also covers representative practical applications of proton, carbon, phosphorus, and tin NMR.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Brookfield, Conn. : Wiley-Blackwell
    Journal of Vinyl and Additive Technology 1 (1995), S. 233-240 
    ISSN: 0193-7197
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The kinetics of the thermal degradation of solid powdered poly(vinyl chloride) (PVC) under nitrogen was studied by thermogravimetry, rate of hydrogen chloride evolution, and rate of polyene sequence formation. These results are accommodated by a chain mechanism involving initiation by random dehydrochlorination at normal monomer residues of PVC, and a series of intermediates, each leaking to a stable conjugated polyene sequence. Structural irregularities such as allylic and tertiary chlorine are responsible for a fast initiation process at the very beginning of the degradation. Mean rate constants and activation parameters for random initiation, propagation, and termination reactions of the PVC degradation chain were calculated by simulation. Activation enthalpy/entropy correlations for the experimental data available for dehydrochlorination of chloroalkanes and chloroalkenes in the gas and in the liquid phase or nonpolar solvents and elementary reactions of PVC degradation show that initiation is an HCl elimination through a transition state of four centers requiring a synperiplanar conformation of the 〉CH-CCl〈 group, whereas propagation is a dehydrochlorination through a transition state of six centers requiring a cis configuration of the double bond.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Metabolism of 1,1,1,2,2-pentafluorohexane with liver microsomes from phenobarbital-treated rats gave only one metabolite, namely, the 5-hydroxy derivative. Under similar conditions 1,1-difluorocyclohexane was metabolized to give mainly the 3- and 4-hydroxy derivatives in the ratio 1:∼5.5 The structures of these metabolites were established by chemical ionization (CI) and/or electron impact (EI) mass spectrometry and confirmed by synthesis in the case of 1,1-difluorocyclohexan-4-ol. Oxidation of 1,1-difluorocyclohexane with lead tetrakis(trifluoroacetate) also gave, inter alia, the 3- and 4-hydroxy derivatives. In saturated hydrocarbons complete replacement of hydrogen by fluorine at one particular carbon will not only block microsomal hydroxylation thereat but will also inhibit hydroxylation at neighbouring hydrogen-bearing carbons, (α almost completely, β markedly, γ slightly).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1988), S. 211-213 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of octafluorotoluene (OFT) as a versatile gas chromatographic/mass spectrometric derivatizing agent for steroids containing alcoholic, phenolic or α,β-unsaturated keto functions, is described. Two distinct derivatizing schemes can be utilized, involving (method 1) a phase-transfer reaction, employing a two-phase system of CH2Cl2 and N NaOH with n-Bu4NHSO4 as catalyst (suitable for alcoholic and phenolic steroids) and (method 2) a reaction conducted in anhydrous dimethylformamide at 155°C with CsF as base (appropriate for α,β-unsaturated keto steroids). Perfluorotolyl (PFT) ethers and/or enol ethers have thus been generated. The electron impact spectra display abundant high-mass molecular ions where derivatization has occurred at a phenolic or enolic function. An extraction, derivatization and gas chromatographic/mass spectrometric scheme has been devised involving method 2 for the analysis of steroids in human plasma. A preliminary quantitative investigation of the levels of testosterone in plasma has been carried out employing these methods. The anomalously high level found is explained in terms of the presence in plasma of lipid-soluble derivatives of testosterone (probably fatty acid esters) which generate the testosterone bis-OFT derivative under the reaction conditions employed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method using particle beam liquid chromatography/mass spectrometry was developed for the confirmation of oxytetracycline, tetracycline and chlortetracycline residues in bovine milk. This method is one of the first to apply particle beam technology to the confirmation of animal drug residues in food products for regulatory purposes. The milk is centrifuged, using molecular weight cut-off filters to remove components of 25 000 daltons and above from the milk. The filtrate is passed through a C-18 sample preparation cartridge which retains the tetracyclines. After the columns are washed with water, the tetracyclines are eluted with 0.1 M oxalic acid in methanol and concentrated. The compounds are separated on a Novapak C-18 column with a methanol-oxalic acid-acetonitrile mobile phase. Negative chemical ionization with selective ion monitoring is used to identify the tetracyclines. The procedure was used to confirm the presence of each tetracycline at 100 ng ml-1 in fortified and incurred milk samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Mass spectra of mercapturic acid conjugates of two xenobiotic products of lipid peroxidation (trans-4-hydroxy-2-hexenal and trans-4-hydroxy-2-nonenal) as well as conjugates of 1,3-dichloropropene, styrene oxide, 1,2-naphthalene oxide and α-chlorotoluene were obtained using fast atom bombardment or negative chemical ionization. Fragmentation pathways were investigated using linked scan and mass-analyzed ion kinetic energy spectrometric techniques. Characteristics of the spectra obtained using different ionization and sample introduction techniques are compared. Deprotonated molecular ions of mercapturic acids gave simple daughter ion spectra, with the dominant mode of decomposition involving cleavage of C—S bonds giving a characteristic neutral loss of 129 Da Screening for mercapturates in urine samples was performed using neutral loss scanning and yielded limits of detection in the low nanogram per milliliter range. Quantitative analysis of the S-benzyl mercapturic acid at 1 p.p.b. in urine has been demonstrated using combined gas chromatography/electron capture mass spectrometry with d3-S-benzyl mercapturic acid as internal standard.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 8 (1981), S. 503-505 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Three physiologically important disaturated lecithins have been analyzed quantitatively as the acetate derivatives using a solids inlet probe and ammonia chemical ionization. Concentration independent response factors have been determined over a tenfold range that brackets human plasma levels. The results obtained serve as an independent corroboration of gas chromatographic analyses.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...