Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 55 (1994), S. 249-252 
    ISSN: 1432-0827
    Keywords: Bone mass ; Ethnicities ; Hawaiian ; Filipino ; Japanese ; White
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Our study compares the bone mass of Hawaiian, Filipino, Japanese, and white women living in Oahu, Hawaii. Eligible women ranged in age from 25 to 34; all had bone mass measurements at the spine, calcaneus, and proximal and distal radius. Their average bone mineral density (BMD) remained stable with age at all four bone sites, indicating that the age range 25–34 may represent the peak bone mass. Bone mass varied, however, between ethnicities; differences in BMD up to 11% were observed. The Hawaiian women had the greatest BMD, and whites had the second greatest BMD at the spine and calcaneus. The Japanese most frequently had the lowest BMD. Differences in body size partly explained the differences; most ethnic differences were reduced or eliminated after adjusting for height and weight. At the spine, the ethnic differences for BMD were also apparent with BMC and with vertebral area. Hawaiian and white women had greater values than Japanese or Filipino women. Differences at the proximal radius resembled the spine, except that whites had the widest proximal widths. The results were more complex for the distal radius. At the distal radius whites had the lowest BMD of the four ethic groups. The difference between whites and Hawaiians derived from the greater bone mineral content (BMC) of the Hawaiian women. By contrast, the difference between whites and the Japanese and Filipinos derived from the wider distal widths of the white women. Compared with the Japanese and Filipino women, the white women appeared to disperse their BMC at the distal radius across a wider bone width. Such differences in bone distributions might lead to an altered risk of distal radius (wrist) fractures. Within ethnicities there was marked variation among individuals in bone mass. At the extremes, women differed by 50–100% or more within all four ethnic groups.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 38 (1992), S. 563-572 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A new approach to gross error detection provides unbiased estimates and 100(1-α)% simultaneous confidence intervals of process variables when biased process measurements and process leaks exist. Presented in this article are estimation equations for process variables, as well as equations that help identify biased measurements and process leaks. These equations include the power function for a global test, and two types of α-level component tests and their power functions. Important strengths and weaknesses of this approach are compared to those of the serial compensation strategy, in particular, by varying the significance level (α), the variance-covariance matrix (Σ), the size of measurement bias (δ), the number of biased variables, and the sample size (N). Accuracy of δ estimation and performance in detecting the presence of process leaks (γ) are also evaluated and compared. The proposed approach has unique features that can provide a basis for improving the reconciliation of variables in process operations.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 39 (1993), S. 1335-1341 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Equations introduced here identify measurement biases and process leaks, when gross errors exist in measured process variables and the variance-covariance matrix of the measurements, Σ, is unknown. Σ is estimated by the sample variance, S, using process data.For an unknown Σ, the global test statistic is the well-known Hotelling T2 statistic. Its power function has a noncentral F-distribution. For component tests used for specific identification of measurement biases and nodal leaks, two tests are presented with Σ unknown. The first test is independent of the number of component tests, k, and is given by a statistic with an F-distribution. The second test depends on k and has a student t-distribution. The power functions for both component tests are provided. Process examples and a Monte Carlo simulation study presented demonstrate the use and performance of these statistical equations in identifying biases and process leaks.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 32 (1986), S. 1116-1124 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A model that describes fractionation with condensation and evaporation in a plate-fin device has been formulated. It is capable of evaluating profiles of composition, temperature, and flow rate for both liquid and vapor streams in an extended surface device. The device may be adiabatic or nonadiabatic and the surface may be incompletely wetted. Compared to experimental measurements, the model predictions showed ± 1 number of transfer unit deviation along the length of the device. The predictions of the top and bottom flow rate ratio showed a 5-10% deviation for adiabatic and condensation runs and a 25% deviation for evaporation runs.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 8 (1962), S. 537-539 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The phase behavior of the methane-carbon dioxide system has been determined experimentally along the solid-liquid-vapor locus. Pressure-temperature measurements were made along this locus from the triple point of carbon dioxide to -284°F. Compositions of the vapor phase along the solid-liquid-vapor locus were determined with sampling techniques over a composition range of 0.1 to 12% carbon dioxide. Liquid-phase compositions were obtained from crystal-point determinations on eleven methane-carbon dioxide mixtures ranging from 0.16 to 20% carbon dioxide.With the pressure-temperature for the solid-liquid-vapor locus as the termination locus of the dew and bubble data of Donnelly and Katz (2), consistent liquid- and vapor-phase compositions were obtained over the remaining concentration range.Changes in the pressure-temperature relationship of the solid-liquid-vapor locus caused by using a methane stock containing 0.56 mole % nitrogen are also reported.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 10 (1964), S. 937-943 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A model is presented to describe the behavior of falling film fractionators with evaporation or condensation. Experimental measurements of vapor composition, vapor temperature and wall temperature profiles were made. Close agreement suggests that the model is applicable to both adiabatic and nonadiabatic conditions.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Osteoporosis international 4 (1994), S. 1-5 
    ISSN: 1433-2965
    Keywords: Bone mass ; Bone density ; Fracture incidence ; Fracture prevalence ; Longitudinal studies ; Risk factors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A prospective cohort study of 1098 postmenopausal Japanese-American women evaluated the relationship between baseline non-spine fractures and new (incident) spine fractures. At the baseline examination in 1981, prevalent non-spine fractures were ascertained by interview, and prevalent spine fractures by radiograph. Bone mass measurements of the distal radius, proximal radius, calcaneus (1981), the lumbar spine (1984) were obtained and repeated at 1- to 2-year intervals. Women with existing non-spine fractures have a threefold greater risk of subsequent spine fractures, independent of bone mass, and independent of the known association between prevalent spine fractures and subsequent spine fractures. Women with both a prevalent non-spine fracture and low bone mass (50th percentile or lower) have an eightfold greater risk of new spine fractures compared with women above the 50th percentile of bone mass and no prevalent fractures. In addition to low bone mass, both prevalent spine fractures and prevalent non-spine fractures are strong risk factors for subsequent spine fracture. These data suggest that not all osteoporotic risk factors are expressed via bone mass, and that other, unmeasured risk factors, such as bone quality defects, may explain these results. In clinical terms, women with both prevalent fractures and low bone mass should be recognized as being at extremely high risk, and treatment potency should be commensurate with this level of risk.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Osteoporosis international 5 (1995), S. 234-238 
    ISSN: 1433-2965
    Keywords: Anthropometry ; Bone mass ; Height ; Osteoporosis ; Weight
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We examined the magnitude of regional variations in bone mass among elderly, Japanese-American men and women. All subjects had bone measurements at the calcaneus, and at the distal and proximal radius sites. A subset of the women had, in addition, spine bone mass measurements. To provide a common measurement scale, the bone measurements were converted to age- and sex-specificZ-scores. TheZ-scores between pairs of bone sites were then subtracted to yield the differences in bone mass between bone sites (expressed inZ-score units). For most individuals the differences were less than 1.0Z-score; however, 12%–20% of the differences were at least 1Z-score apart. The most similar sites were the distal and proximal radius: different regions within the same bone. Among the other bone pairs, the calcaneus and spine were the most similar to one another. The magnitudes of the differences in bone mass were associated with height and weight. Heavier subjects, for instance, had greater calcaneus than radius bone mass measurements, and greater spine than radius measurements. The spine and calcaneus are more weight-bearing than the radius sites. Associations were observed up to 0.25Z-score per 10 kg difference in weight. Height was associated with bone mass differences in an opposite direction to weight. Taller subjects had greater bone mass at the radius sites than expected from their calcaneus or spine bone measurements (0.1 to 0.2Z-score difference per 5 cm difference in height). Bone width partly explained the associations with height; that is, adjusting the radius widths reduced the associations with height. Overall, our results indicate that small to moderate differences between bone sites were common among our study population, and that the magnitudes of the differences were associated with height and weight.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...