Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 437-438 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; HPLC ; Diffusion coefficients ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 607-609 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Polar solvents ; On-column injection ; Large volumes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 604-607 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Two-phase acylation ; Aziridine ; 2-Chloroethylamine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The determination of small, water soluble amines such as aziridine and 2-chloroethylamine, in drug substances at trace levels is described. After removal of the bulk of the drug substance by extraction or precipitation, derivatization with acid chlorides is performed. In a two-phase (water-organic solvent) system, this derivatization reaction is accomplished almost simultaneously with the extraction of the product to the organic layer. The organic layer is analyzed by gas chromatography using on-column injection and selective detection. Detection limits are approx. 0.2 mg/kg for aziridine and approx. 0.5 mg/kg for 2-chloroethylamine.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 61 (1996), S. 685-695 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Membrane formation of polylactides has been studied using in situ analysis techniques. An experimental method based on the use of dark ground optics and reflected light illumination is used to monitor the mass transfer and phase separation dynamics during for mation. Additionally, the phase separation and structure formation has been studied using optical microscopy. The results of the dark ground optics technique for the polymer/solvent/nonsolvent systems poly-L-lactide/chloroform/methanol and poly-DL-lactide/chloroform/methanol showed that the diffusion kinetics were similar for the semicrystalline poly-L-lactide (PLLA) and the amorphous poly-DL-lactide. The influence of the molecular weight of the polymers on the diffusion kinetics was found to be negligible. Increasing the polymer concentration of the casting solution decreased the rate of diffusion. The phase separation of poly-DL-lactide was studied with optical microscopy and found to proceed via liquid-liquid demixing. For poly-L-lactide solutions of relatively low concentration (5-6% w/w), phase separation proceeded via liquid-liquid demixing followed by crystallization. For more concentrated PLLA solutions, phase separation proceeded directly via solid-liquid demixing processes. Additionally, for 6% w/w solutions of poly-L-lactide in dioxane immersed in methanol, precipitation also occurred solely via solid-liquid demixing. © 1996 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 16 (1974), S. 181-208 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: An experimental investigation on the rheology of penicillin broths was undertaken in order to obtain more understanding of this important aspect of the fermentation process. The measuring technique consisted in observation of the torque exerted upon a rotating turbine impeller. The experimental data were interpreted in terms of a model which basically is a synthesis of a known relationship for the rheological behavior of printing ink (Casson equation) and some considerations analogous to the rheological description of polymer solutions (excluded volume concept). One of the key variables in the model is a morphology factor, which can be used for a quantitative description of mycelial morphology. The value of the morphology factor can be determined experimentally by a simple viscosity measurement in combination with a mycelial dry weight determination. There are strong indications that the model may be applicable to mycelial broths other than those of penicillin.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; On-line extraction ; Large volume injection ; Hexachlorocyclohexanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 29 (1984), S. 4265-4277 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Melt polymerization conditions for D,L-lactide initiated with tetraphenyltin were studied with regard to polymer molecular weight and weight distributions. “Single” polymerization, “multiple” polymerization (four or eight reactions at the same time), and time-dependent studies are described. Single polymerizations using constant initiator concentrations resulted in a broad scattering of nonreproducible molecular weight values. Multiple polymerizations at constant initiator concentrations, however, resulted in nearly identical molecular weight profiles. Multiple polymerizations at different initiator concentrations did not show an inverse dependency of initiator concentration on polymer molecular weight. Both the single and multiple melt polymerizations resulted in rather broad molecular weight distributions. The presence of hydrolysis products of lactide during the melt polymerization most likely has a detrimental effect on molecular weight. After a short induction period the rather slow polymerization of D,L-lactide resulted in a maximal molecular weight followed by a slight decrease in molecular weight to a constant value. It is concluded that the polymerization of D,L-lactide in the melt initiated with tetraphenyltin does not proceed through a “living” mechanism.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 34 (1996), S. 2553-2568 
    ISSN: 0887-6266
    Keywords: ternary phase diagrams ; polylactides ; Flory-Huggins ; demixing ; membranes ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Isothermal phase diagrams for the semicrystalline poly-L-lactide (PLLA) and the amorphous poly-DL-lactide (PDLLA) in combination with several solvent-nonsolvent combinations (dioxane/water, dioxane/methanol, chloroform/methanol, and NMP/water) have been determined. The locations of the liquid-liquid miscibility gap, the solid-liquid miscibility gap and the vitrification boundary in the isothermal phase diagrams at 25°C were identified. The liquid-liquid miscibility gap for the systems with PLLA was located in the same composition range as the corresponding systems with PDLLA. For the systems containing PLLA solid-liquid demixing was thermodynamically preferred over liquid-liquid demixing. Attempts were made to correlate the experimental findings with predictions on the basis of the Flory-Huggins theory for ternary solutions using interaction parameters derived from independent experiments. Qualitative agreement was found between the theoretical predictions and the experimentally obtained liquid-liquid miscibility gap. No good agreement was found for the solid-liquid miscibility gap. © 1996 John Wiley & Sons, Inc.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0887-6266
    Keywords: polylactide ; membrane formation ; morphology ; crystallization ; liquid-liquid demixing ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The influence of liquid-liquid demixing, solid-liquid demixing, and vitrification on the membrane morphologies obtained from several polylactide-solvent-nonsolvent systems has been investigated. The polymers investigated were the semicrystalline poly-L-lactide (PLLA) and the amorphous poly-DL-lactide (PDLLA). The solvent-nonsolvent systems used were dioxane-water, N-methyl pyrrolidone-water and dioxane-methanol. For each of these systems it was attempted to relate the membrane morphology to the ternary phase diagram at 25°C. It was demonstrated that for the amorphous poly-DL-lactide the intersection of a glass transition and a liquid-liquid miscibility gap in the phase diagram was a prerequisite for the formation of stable membrane structures. For the semicrystalline PLLA a wide variety of morphologies could be obtained ranging from cellular to spherulitical structures. For membrane-forming combinations that show delayed demixing, trends expected on the basis of phase diagrams were in reasonable agreement with the observed membrane morphologies. Only for the rapidly precipitating system PLLA-N-methyl pyrrolidone-water were structures due to liquid-liquid demixing obtained when structures due to solid-liquid demixing were expected. Probably, rapid precipitation conditions promote solid-liquid demixing over liquid-liquid demixing, because the activation energy necessary for liquid-liquid demixing is lower than that for crystallization. © 1996 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 14 (1989), S. 393-400 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A system of optics for electron impact post-ionization sputtered neutral mass spectrometry (SNMS) has been designed and constructed. The design is based on an existing set of ‘Wittmaack-box’-type secondary ion mass spectrometry (SIMS) optics, commercially operational at UMIST. The system operates with ‘state of the art’ efficiency in the SNMS mode (a post-ionization efficiency of 10-3-10-4), without significant degradation of the SIMS operation.The development stages described demonstrate many of the practical problems in the design of an electron beam post-ionizer, involving characterization of the energy analyser used and the conditions from the optics for best secondary ion and residual gas suppression in the SNMS mode.Calibration of the SNMS mode of the system has been undertaken using standardized samples, cross-calibrated by optical emission spectroscopy. (Typical spectra of standard stainless steel and some CuZn and CuAl alloys are presented.) These studies revealed a reproducibility of better than 10% in the relative sensitivity factors, which have been assigned to several elemental species. From these studies, a detection limit of better than 0.01 at.% was obtained for most elemental species under 10 μA Ar+ primary beam bombardment.The effects of surface roughness on the efficiency of sputtered neutral collection are reported. Studies of CuZn alloys have revealed effects on the absolute calibration and on data analysis of multicomponent materials where the individual components have differing sputter yields. This study also revealed SNMS to be a useful tool in the measurement of the sputter yields of composite materials. Studies of InAsxP1-x have been used to demonstrate the linearity of SNMS for quantitative analysis, as well as revealing the homogeneity of the layers analysed.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...