Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Blood pressure  (2)
  • Acid-base status  (1)
  • Childhood  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    European journal of pediatrics 125 (1977), S. 227-234 
    ISSN: 1432-1076
    Schlagwort(e): Blood volume ; Height ; Weight ; Body surface area ; Infancy ; Childhood
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Blood volume was studied in 160 infants and children aged from one hour to 14 years. From these data linear and logarithmic regression equations relating blood volume to weight, height and surface area were calculated. Equations utilizing combined height and logarithmic weight values were found to be the most accurate for predicting blood volume. Therefore, nomograms were constructed for reading blood volume directly from height and weight.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1076
    Schlagwort(e): Blood pressure ; Blood viscosity ; Blood volume ; Newborn infants ; Peripheral blood flow ; Peripheral resistance ; Premature infants ; Respiratory distress
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Peripheral blood flow and systolic blood pressure (strain-gauge plethysmograph), blood volume (Evans blue) and whole blood viscosity (cone-plate viscometer) have been measured in 66 premature and full-term infants 6 to 144h of age. Blood flow and blood volume were moderately decreased in the infants with respiratory distress. Highly significant (P〈0.001) correlations were found betwen blood flow and blood volume (r=0.77), blood pressure and blood volume (r=0.50), peripheral resistance and blood volume (r=-0.44), blood flow and blood pressure (r=0.50), blood flow and peripheral resistance (r=-0.67), peripheral resistance and blood viscosity (r=0.45), and blood viscosity and haematocrit (r=0.86). There was no correlation between peripheral blood flow and blood viscosity. However, at given blood volume, peripheral blood flow decreased with increasing blood viscosity. These results indicate that in newborn infants peripheral blood flow, blood pressure and peripheral resistance are influenced by blood volume, but also depend on blood viscosity.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    European journal of pediatrics 127 (1977), S. 9-14 
    ISSN: 1432-1076
    Schlagwort(e): Newborn infants ; Blood pressure ; Hematocrit ; Blood volume ; Acid-base status ; Red cell mass ; Peripheral blood flow
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Venous and capillary hematocrit, acid base values, and circulatory parameters were measured simultaneously in 92 newborn infants within six hours of birth. Gestational age ranged from 26 to 41 weeks. The capillary/ venous hematocrit ratio (Hctc/Hctv) was greater than 1.00 in 89 infants. We found significant inverse correlations between Hctc/Hctv and several parameters, such as pH (r=-0.82), standard bicarbonate (r=-0.73), systolic blood pressure (r=-0.51), and peripheral blood flow (r=-0.70). Most of the infants with a Hctc/Hctv of 1.20 and above had red cell mass values of less than 35 ml/kg. However, blood volume apparently did not influence the Hctc/Hctv. Gestational age appeared to affect Hctc/Hctv only before 30 weeks, when compared with the Hctc/Hctv of term infants. Our results indicate that disturbed circulation, and in particular, disturbed microcirculation, is involved in the development of high Hctc/Hctv ratios. We strongly advise that hematocrits obtained by skin prick from a sick newborn infant should not be relied on as they may give misleading information on oxygen carrying capacity to vital organs.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...