Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Digitale Medien  (6)
  • Inorganic Chemistry  (4)
  • Complications  (2)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Der Anaesthesist 49 (2000), S. 1018-1023 
    ISSN: 1432-055X
    Schlagwort(e): Schlüsselwörter Infusionssysteme ; Spritzenpumpen ; Luft ; Fehlerquellen ; Gefahren ; Keywords Syringe pumps ; Air ; Infusion line occlusion ; Drug delivery ; Complications
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Abstract Application of highly concentrated short-acting vasoactive drugs in the critically ill patient requires precisely working syringe pump systems for continuous intravenous drug delivery. We performed a bench study to investigate the consequences of small amounts of air entrapped within a 50-ml infusion syringe. In particular we studied the effect of entrapped air on drug delivery after moderate vertical displacement of the pump by 50 cm (e. g. in preparation for transport) and the effect on the time required to trigger the pressure alarm after occlusion of the infusion line. At a flow rate of 1 ml/h, lowering the syringe pump prolonged the zero-drug delivery time from (mean±SD) 4.1±0.8 min (without air) to 6.2±0.9 (with 1 ml air) and to 13.1±0.9 min (with 2 ml of air, p〈0.001 for all comparisons). Entrapping of 2 ml of air within the syringe resulted in a 2.6-fold prolongation of the occlusion alarm time after accidental occlusion of the infusion line and a 3-fold increase of the resulting infusion bolus after occlusion. Enclosed air within infusion syringes considerably affects the syringe compliance. It increases the susceptibility of constant drug delivery to vertical displacement of syringe pumps and impairs the occlusion alarm function. Therefore, any air in syringe of infusion pump systems should be carefully removed. To avoid infusion boluses of short-acting vasoactive drugs after accidental occlusions, the occluded infusion line should be released to ambient pressure first.
    Notizen: Zusammenfassung Werden hochdosierte kreislaufwirksame Pharmaka mit kurzer Halbwertszeit bei niedrigen Flussraten appliziert (z. B. bei Neugeborenen oder in der Kinder-Herzchirurgie), so ist eine konstante Zufuhr des Medikaments für die hämodynamische Stabilität eine unabdingbare Voraussetzung. Wir untersuchten in einem experimentellen Modell den Einfluss von geringen Luftmengen in 50-ml-Infusionsspritzen auf die Konstanz der Flussrate und die Alarmfunktion in 2 klinisch relevanten Situationen: relative Niveauänderungen zwischen Spritzenpumpe und Patient (etwa bei Transport oder Umlagern) und akzidentieller Verschluss (etwa Abknicken) einer Infusionsleitung. Nach Absenken der Spritzenpumpe um 50 cm gegenüber dem Ausgangsniveau verlängerte sich die Zeit unterbrochener Medikamentzufuhr (wegen hydrostatischer, retrograder Aspiration) von 4,1 min ohne Lufteinschluss auf 6,2 min bei 1 ml und auf 13,1 min bei 2 ml Lufteinschluss. Bei akzidentiellem Verschluss verlängerte sich die Zeit bis zum Okklusionsalarm bei 2 ml Lufteinschluss um das 2,6fache auf über 1 h, der resultierende Bolus nach Aufheben des Verschlusses verdreifachte sich. Daher sollten bei der Zufuhr hochkonzentrierter Vasoaktiva nicht nur relative Lageveränderungen zwischen System und Patient vermieden, sondern jegliche eingeschlossene Luft konsequent evakuiert werden. Dies gilt gleichermassen für alle über dasselbe Katheterlumen infundierenden Perfusoren. Bei Erkennen eines Verschlusses ist es sinnvoll, das okkludierte Infusionssystem vom Patienten zu trennen und den Druckentlastungsbolus zu verwerfen, bevor der Verschluss aufgehoben wird.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 26 (2000), S. 942-949 
    ISSN: 1432-1238
    Schlagwort(e): Key words Ventilator-associated pneumonia ; Cardiac surgery ; Children ; Pediatric intensive care ; Complications ; Extubation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: This study was undertaken to determine the delay of extubation attributable to ventilator-associated pneumonia (VAP) in comparison to other complications and complexity of surgery after repair of congenital heart lesions in neonates and children.¶Methods: Cohort study in a pediatric intensive care unit of a tertiary referral center. All patients who had cardiac operations during a 22-month period and who survived surgery were eligible (n = 272, median age 1.3 years). Primary outcome was time to successful extubation. Primary variable of interest was VAP. Surgical procedures were classified according to complexity. Cox proportional hazards models were calculated to adjust for confounding. Potential confounders comprised other known risk factors for delayed extubation.¶Results: Median time to extubation was 3 days. VAP occurred in 26 patients (9.6 %). The rate of VAP was not associated with complexity of surgery (P = 0.22), or cardiopulmonary bypass (P = 0.23). The adjusted analysis revealed as further factors associated with delayed extubation: other respiratory complications (n = 28, chylothorax, airway stenosis, diaphragm paresis), prolonged inotropic support (n = 48, 17.6 %), and the need for secondary surgery (n = 51, 18.8 %; e. g., re-operation, secondary closure of thorax). Older age promoted early extubation. The median delay of extubation attributable to VAP was 3.7 days (hazards ratio HR = 0.29, 95 % CI 0.18–0.49), exceeding the effect size of secondary surgery (HR = 0.48) and other respiratory complications (HR = 0.50).¶Conclusion: VAP accounts for a major delay of extubation in pediatric cardiac surgery.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 334 (1964), S. 15-20 
    ISSN: 0044-2313
    Schlagwort(e): Chemistry ; Inorganic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Beschreibung / Inhaltsverzeichnis: The precipitation of diphosphate from solutions of secondary alkali diphosphates by means of Ba2+ yields the acid salt Ba7H2P8O28·6H2O. With increasing alkalinity of the solutions, the hydrogen ion content of the Ba salt precipitate decreases. Precipitation from Na4-diphosphate solutions yields the neutral Ba2P2O7·1,5 H2O. From X-ray investigations (no structural differences between the two precipitates being found) it in concluded that the “neutral” Ba diphosphate has a phase range from Ba:H = 2:0 to 7:2.
    Notizen: Ba2+ bildet-im Unterschied zu vielen anderen zweiwertigen Metallen-bei der Fällung aus Lösungen sekundärer Diphosphate ein saures Diphosphat, Ba7H2P8O28·6H2O. Mit steigender Alkalität der Fällungslösung nimmt die Acidität der Ba-Verbindung ab. Das neutrale Na-Diphosphat entsteht nur bei der Fällung aus quaternären Diphosphat-Lösungen. Bemerkenswerterweise besteht kein struktureller Unterschied zwischen den sauren Verbindungen und dem quaternären Salz, was zu der Annahme führt, daß das quaternäre Ba-Diphosphat eine Phasenbreite zwischen Ba:H = 2:0 und 7:2 besitzt.
    Zusätzliches Material: 2 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 458 (1979), S. 177-182 
    ISSN: 0044-2313
    Schlagwort(e): Chemistry ; Inorganic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Beschreibung / Inhaltsverzeichnis: Pseudochalcogeno Compounds. XI. On a New Type of Pseudochalcogeno-Modified PhosphatesThe preparation of pseudochalcogenophosphates of the general formulas [PO3Y]3- and [P2O7-nYn]4- (Y = C(CN)2, n = 1, 2) is described. Chromatography of sodium salts, the formation of silver and calcium salts, characteristic IR and 31P-NMR data are discussed.
    Notizen: Es wird über die Synthese von Pseudochalkogenophosphaten der allgemeinen Formeln [PO3Y]3-, [P2O7-nYn]4- (Y = C(CN)2, n = 1, 2) berichtet. Chromatographisches Verhalten der Natriumsalze, Silber- und Calciumsalzbildung, charakteristische IR- und 31P-NMR-Daten werden diskutiert.
    Zusätzliches Material: 1 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 57 (1924), S. 1653-1656 
    ISSN: 0365-9631
    Schlagwort(e): Chemistry ; Inorganic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 56 (1923), S. 1012-1013 
    ISSN: 0365-9631
    Schlagwort(e): Chemistry ; Inorganic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...