Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1106
    Keywords: Auditory cortex ; Computer microscopy ; Dendrites ; Golgi ; Orientation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In the tangential plane (parallel to the pial surface) dendrites in the primary auditory cortex (A1) of cat were found to exhibit preferentially oriented growth. This was shown by means of a computer microscope study of Golgi-Cox stained neurons as seen in 100 μm and 300 μm thick tangential sections. Two techniques were used to represent the 3-dimensional structure of dendrites: the “dendritic stick” and the “dendritic trumpet”. The former dismembers a dendrite into its individual segments; the latter considers a dendrite as an entity and represents it by its centroid, its moments and the spatial dispersion of its branches. Both statistical and Fourier analyses of the data show that within the tangential plane there is a significant and consistent orientation of the dendritic sticks in a dorso-ventral direction which seems correlated with the cortical isofrequency contours observed in electrophysiological maps of the A1 region. The dendritic trumpet analyses also show a distinctly non-random vertical distribution of pyramidal cell basal dendrites but not of stellate cell dendrites.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 42 (1993), S. 387-393 
    ISSN: 0006-3592
    Keywords: biosensor ; glucose ; fructose ; gluconolactone ; sorbitol ; Zymomonas mobilis ; permeabilization ; NADPH ; fluorescence ; bioprocess monitoring ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Using permeabilized Zymomonas mobilis or glucose-fructose oxidoreductase isolated from this microorganism a model system for biosensors with a protein confined NADP(H) cofactor for the determination of glucose, fructose, gluconolactone, and sorbitol was developed. Either permeabilized microorganisms containing the oxidoreductase or the pure enzyme were confined via membrane separation in a small measuring chamber, that was integrated into a flow injection analysis system (FIA). The measuring principle was the monitoring of the NAD(P)H fluorescence, excited at 360 nm and measured at 450 nm. NADP(H), which is confined in the protein complex, was oxidized or reduced during the enzymatic reactions and the changes in the fluorescence intensity were related to the substrate concentration. The sensitivity of the system covered a range from 0.001 to 100 g/L of the analyte depending on substrate and operating conditions. The applicability of this model system for bioprocess monitoring was proved using samples from a Pseudomonas pseudoflava cultivation. © 1993 John Wiley & Sons, Inc.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...