Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Cyprinidae  (1)
  • Key words Nonthoracotomy cardioverter/defibrillator systems – lead failures – device implemented diagnostic and measurement features – automated system control with patient alert  (1)
  • 1
    ISSN: 1573-4927
    Keywords: evolution ; polyploidy ; RNA content ; protein content ; enzyme activities ; Cyprinidae ; Isospondyli
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract The ratio of cellular RNA and protein content is about 1:1 between phylogenetically diploid and tetraploid species of the teleost family Cyprinidae, but is roughly in proportion to ploidy in species of the teleost order Isospondyli. Enzyme activities do not unequivocally comply with this scheme. These findings are discussed in view of the hypothesis that a regulatory mechanism which reduces genic activity has evolved in the tetraploid cyprinids but not in the tetraploid species of the order Isospondyli.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1435-1285
    Keywords: Schlüsselwörter Transvenöse Kardioverter/Defibrillator-Elektrodensysteme – Elektrodendysfunktionen – systemintegrierte Diagnose- und Meßfunktionen – automatisierte Systemkontrolle ; Key words Nonthoracotomy cardioverter/defibrillator systems – lead failures – device implemented diagnostic and measurement features – automated system control with patient alert
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The aim of this study is the analysis of electrical failures in transvenous cardioverter/defibrillator (ICD) lead systems with regard to the importance of device implemented diagnostic and measurement functions and the potential role of an automated device-control in the detection of lead failures. Methods: All consecutive ICD patients at our institution were enrolled in this retrospective investigation. The routine follow-up controls consisted in a complete evaluation of all diagnostic and measurement ICD features and additional controls in when spontaneous arrhyhtmia episodes occurred. Results: Two hundred thirty patients, 193 male and 37 female, were enrolled in this study (mean age: 61.5±10.2 years; mean LVEF was 32±9%). During a mean follow-up period of 29.5±18.4 (6–76) months, lead failure occurred in 19 patients (8%). 16 patients were implanted with an ICD, capable of diagnostic and measurements functions. All nonadequate device discharges could be classified as sensing-failure by stored electrograms. Device implemented measurement features revealed clinical important information in 13/16 patients (81%). In 14/16 patients, the lead defect could not be detected during routine follow-up. At the time of documented lead failure the safety of the implanted devices was already lost in 6/16 patients (38%). Conclusions: Device implemented diagnostic and measurement options are of great importance in the early detection of ICD lead failures. The implementation of automated measurements of lead related parameters in connection with a patient alert function may contribute to a further increase in the safety of ICD therapy.
    Notes: Zusammenfassung Das Ziel dieser Studie ist die Analyse elektrischer Dysfunktionen transvenöser Kardioverter/Defibrillator-(ICD-)Elektrodensysteme hinsichtlich der Bedeutung systemintegrierter Diagnose- und Meßfunktionen und der Möglichkeit einer automatisierten Systemkontrolle von ICD-Generatoren für eine sichere und schnelle Erkennung von Elektrodendefekten. Methoden: Alle konsekutiven ICD-Patienten unserer Klinik wurden in die vorliegende, retrospektive Untersuchung einbezogen. Die Verlaufskontrolle umfaßte die regelmäßige, vollständige Systemprüfung der ICD-Systeme und zusätzliche Kontrollen bei spontanen Arrhythmieepisoden. Ergebnisse: 230 konsekutive Patienten, 193 Männer, 37 Frauen, wurden in die Untersuchung einbezogen (mittleres Alter: 61,5±10,2 Jahre; mittlere LVEF 32±9%). Während einer Nachbeobachtungsperiode von 29,5±18,4 Monaten (6–76 Monate) wurden bei 19 Patienten (8%) Defekte der ICD-Elektrodensysteme dokumentiert. 16 Patienten trugen einen ICD-Generator mit systemimplementierten Diagnose- und Meßfunktionen. Alle nichtadäquaten ICD-Entladungen konnten durch die Analyse gespeicherter Elektrogramme als Fehlfunktion klassifiziert werden. Die systemintegrierten Meßfunktionen zeigten bei 13 von 16 Patienten (81%) diagnostisch verwertbare Ergebnisse. Bei 14/16 Patienten konnte der Elektrodendefekt im Rahmen der Nachsorge nicht rechtzeitig erkannt werden. Zum Zeitpunkt der Diagnosestellung war bei 6/16 Patienten (38%) die Therapiesicherheit des implantierten ICD-Systems nicht mehr gewährleistet. Schlußfolgerung: Systemintegrierte Diagnose- und Meßfunktionen sind eine wichtige Option zur Erkennung von ICD-Elektrodendefekten. Die Einführung systemintegrierter, automatisch durchgeführter Kontrollen aller elektrodenbezogenen Meßwerte in Verbindung mit Patientenwarneinrichtung könnte zu einer weiteren Steigerung der Sicherheit der Therapie mit implantierbaren Kardioverter/Defibrillatoren beitragen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...